메뉴 건너뛰기




Volumn 35, Issue 6, 2004, Pages 449-455

Simulating periodontal effects in dental osseointegrated implants: Effect of an intramobile damping element on the fatigue strength of dental implants - An in vitro test method

Author keywords

Damping; Dental implant; Fatigue test; Implant system; Retaining screw; Simulating periodontal effects

Indexed keywords

POLY(METHYL METHACRYLATE); TITANIUM;

EID: 2442461930     PISSN: 00336572     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (9)

References (15)
  • 2
    • 0030179504 scopus 로고    scopus 로고
    • Efficacy of the intramobile connector in implant tooth-supported fixed prostheses: An experimental stress analysis
    • Uysal H, Iplikcioglu H, Avci M, Bilir OG, Kural O. Efficacy of the intramobile connector in implant tooth-supported fixed prostheses: An experimental stress analysis. Int J Prosthodont 1996;9:355-361.
    • (1996) Int J Prosthodont , vol.9 , pp. 355-361
    • Uysal, H.1    Iplikcioglu, H.2    Avci, M.3    Bilir, O.G.4    Kural, O.5
  • 3
    • 84989551491 scopus 로고
    • Crown retention and cyclic loading (in vitro)
    • Gundler A, Lockowandt P, Erhardson S. Crown retention and cyclic loading (in vitro). Scand J Dent Res 1993;101 (4):252-256.
    • (1993) Scand J Dent Res , vol.101 , Issue.4 , pp. 252-256
    • Gundler, A.1    Lockowandt, P.2    Erhardson, S.3
  • 4
    • 0020688695 scopus 로고
    • Development of an artificial oral environment for the testing of dental restoratives: Bi-axial-force and movement control
    • DeLong R, Douglas WH. Development of an artificial oral environment for the testing of dental restoratives: Bi-axial-force and movement control. J Dent Res 1983;62:32-36.
    • (1983) J Dent Res , vol.62 , pp. 32-36
    • DeLong, R.1    Douglas, W.H.2
  • 5
    • 0032617540 scopus 로고    scopus 로고
    • Experimental study of the damping behaviour of IMZ implants
    • Haas R, Bemhart T, Dörtbudak O, Mailath G. Experimental study of the damping behaviour of IMZ implants. J Oral Rehabil 1999;26:19-24.
    • (1999) J Oral Rehabil , vol.26 , pp. 19-24
    • Haas, R.1    Bemhart, T.2    Dörtbudak, O.3    Mailath, G.4
  • 7
    • 0034176889 scopus 로고    scopus 로고
    • Viscoelastic dissipation in compact bone: Implications for stress induced fluid flow in bone
    • Garner E, Lakes R, Lee T, Swan C, Brand R. Viscoelastic dissipation in compact bone: Implications for stress induced fluid flow in bone. J Biomech Eng 2000;122:166-172.
    • (2000) J Biomech Eng , vol.122 , pp. 166-172
    • Garner, E.1    Lakes, R.2    Lee, T.3    Swan, C.4    Brand, R.5
  • 8
    • 0242367459 scopus 로고    scopus 로고
    • Prediction of mechanical properties of the cancellous bone of the mandibular condyle
    • van Ruijven LJ, Giesen EB, Farella M, van Eijden TM. Prediction of mechanical properties of the cancellous bone of the mandibular condyle. J Dent Res 2003;82:819-823.
    • (2003) J Dent Res , vol.82 , pp. 819-823
    • Van Ruijven, L.J.1    Giesen, E.B.2    Farella, M.3    Van Eijden, T.M.4
  • 9
    • 0023585639 scopus 로고
    • Intramobile cylinder (IMZ) two-stage osteointegrated implant system with the intramobile element (IME): Part I. Its rationale and procedure for use
    • Babbush CA, Kirsch A, Mentag PJ, Hill B. Intramobile cylinder (IMZ) two-stage osteointegrated implant system with the intramobile element (IME): Part I. Its rationale and procedure for use. Int J Oral Maxillofac Implants 1987; 2:203-216.
    • (1987) Int J Oral Maxillofac Implants , vol.2 , pp. 203-216
    • Babbush, C.A.1    Kirsch, A.2    Mentag, P.J.3    Hill, B.4
  • 10
    • 0034169356 scopus 로고    scopus 로고
    • Effect of an antirotation resistance form on screw loosening for single implant-supported crowns
    • Aboyoussef H, Weiner S, Ehrenberg D. Effect of an antirotation resistance form on screw loosening for single implant-supported crowns. J Prosthet Dent 2000;83:450-455.
    • (2000) J Prosthet Dent , vol.83 , pp. 450-455
    • Aboyoussef, H.1    Weiner, S.2    Ehrenberg, D.3
  • 11
    • 0024759092 scopus 로고
    • A comparison of the stress transfer characteristics of a dental implant with a rigid or a resilient internal element
    • McGlumphy EA, Campagni WV, Peterson LJ. A comparison of the stress transfer characteristics of a dental implant with a rigid or a resilient internal element. J Prosthet Dent 1989; 62(5):586-593.
    • (1989) J Prosthet Dent , vol.62 , Issue.5 , pp. 586-593
    • McGlumphy, E.A.1    Campagni, W.V.2    Peterson, L.J.3
  • 12
    • 0024201743 scopus 로고
    • The ability of currently available stress-breaking elements for osseointegrated implants to imitate natural tooth mobility
    • Lill W, Matejka M, Rambousek K, Watzek G. The ability of currently available stress-breaking elements for osseointegrated implants to imitate natural tooth mobility. Int J Oral Maxillofac Implants 1988;3(4):281-286.
    • (1988) Int J Oral Maxillofac Implants , vol.3 , Issue.4 , pp. 281-286
    • Lill, W.1    Matejka, M.2    Rambousek, K.3    Watzek, G.4
  • 13
    • 0022032459 scopus 로고
    • Long-term effects on chewing with mandibular fixed prostheses on osseointegrated implants
    • Lindquist LW, Carlsson GE. Long-term effects on chewing with mandibular fixed prostheses on osseointegrated implants. Acta Odontol Scand 1985;43:39-45.
    • (1985) Acta Odontol Scand , vol.43 , pp. 39-45
    • Lindquist, L.W.1    Carlsson, G.E.2
  • 15
    • 0018560046 scopus 로고
    • Mandibular movements of young adults recorded by intraorally placed light-emitting diodes
    • Jemt T, Karlsson S, Hedegard B. Mandibular movements of young adults recorded by intraorally placed light-emitting diodes. J Prosthet Dent 1979;42:669-673.
    • (1979) J Prosthet Dent , vol.42 , pp. 669-673
    • Jemt, T.1    Karlsson, S.2    Hedegard, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.