-
1
-
-
84963068201
-
Sample Enrichment Techniques for a Gas Chromatograph/Mass Spectrometer Analysis System
-
Lucero D.P., Haley F.C. Sample Enrichment Techniques for a Gas Chromatograph/Mass Spectrometer Analysis System. J. Gas Chromatogr. 6:1968;477-482
-
(1968)
J. Gas Chromatogr.
, vol.6
, pp. 477-482
-
-
Lucero, D.P.1
Haley, F.C.2
-
2
-
-
0014506008
-
Membrane Molecular Separators for Gas Chromatographic-Mass Spectrometric Interfaces
-
Black D.R., Flath R.A., Teranishi R. Membrane Molecular Separators for Gas Chromatographic-Mass Spectrometric Interfaces. J. Chromatogr. Sci. 7:1969;284-289
-
(1969)
J. Chromatogr. Sci.
, vol.7
, pp. 284-289
-
-
Black, D.R.1
Flath, R.A.2
Teranishi, R.3
-
3
-
-
0035528449
-
Organic Impurity Preconcentration by a Multimembrane Inlet System of a Mass Spectrometer
-
Kogan V.T., Viktorova O.S. Organic Impurity Preconcentration by a Multimembrane Inlet System of a Mass Spectrometer. Tech. Phys. Lett. 27:(12):2001;984-986
-
(2001)
Tech. Phys. Lett.
, vol.27
, Issue.12
, pp. 984-986
-
-
Kogan, V.T.1
Viktorova, O.S.2
-
4
-
-
0000923801
-
Theoretical Analysis of Probe Dynamics in Flow Injection/Membrane Introduction Mass Spectrometry
-
Tsai G.J., Austin G.D., Syu M.J., Tsao G.T., Hayward M.J., Kotiaho T., Cooks R.G. Theoretical Analysis of Probe Dynamics in Flow Injection/Membrane Introduction Mass Spectrometry. Anal. Chem. 63:1991;2460-2465
-
(1991)
Anal. Chem.
, vol.63
, pp. 2460-2465
-
-
Tsai, G.J.1
Austin, G.D.2
Syu, M.J.3
Tsao, G.T.4
Hayward, M.J.5
Kotiaho, T.6
Cooks, R.G.7
-
5
-
-
0029996221
-
A Mathematical Study of Sample Modulation at a Membrane Inlet Mass Spectrometer - Potential Application in Analysis of Mixtures
-
Overney F.L., Enke C.G. A Mathematical Study of Sample Modulation at a Membrane Inlet Mass Spectrometer - Potential Application in Analysis of Mixtures. J. Am. Soc. Mass Spectrom. 7:1996;93-100
-
(1996)
J. Am. Soc. Mass Spectrom.
, vol.7
, pp. 93-100
-
-
Overney, F.L.1
Enke, C.G.2
-
7
-
-
0035891910
-
Application of the Numerical Model Describing Analyte Permeation Through Hollow Fiber Membranes into Vacuum for Determination of Permeation Parameters of Organic Compounds in a Silicone Membrane
-
Sysoev A.A., Ketola R.A., Mattila I., Tarkiainen V., Kotiaho T. Application of the Numerical Model Describing Analyte Permeation Through Hollow Fiber Membranes into Vacuum for Determination of Permeation Parameters of Organic Compounds in a Silicone Membrane. Int. J. Mass Spectrom. 212:2001;205-217
-
(2001)
Int. J. Mass Spectrom.
, vol.212
, pp. 205-217
-
-
Sysoev, A.A.1
Ketola, R.A.2
Mattila, I.3
Tarkiainen, V.4
Kotiaho, T.5
-
8
-
-
0034257834
-
A Mathematical Model for Kinetic Study of Analyte Permeation from Both Liquid and Gas Phases Through Hollow Fiber Membranes into Vacuum
-
Sysoev A.A. A Mathematical Model for Kinetic Study of Analyte Permeation from Both Liquid and Gas Phases Through Hollow Fiber Membranes into Vacuum. Anal. Chem. 72:2000;4221-4229
-
(2000)
Anal. Chem.
, vol.72
, pp. 4221-4229
-
-
Sysoev, A.A.1
-
9
-
-
0442297659
-
Membrane Injector for Portable Mass Spectrometer
-
Kogan V.T., Viktorova O.S., Gladkov G.J., Chichagov Y.V., Tubol'tsev Y.V. Membrane Injector for Portable Mass Spectrometer. Instrum. Experim. Techniques. 44:(1):2001;107-110
-
(2001)
Instrum. Experim. Techniques
, vol.44
, Issue.1
, pp. 107-110
-
-
Kogan, V.T.1
Viktorova, O.S.2
Gladkov, G.J.3
Chichagov, Y.V.4
Tubol'Tsev, Y.V.5
-
10
-
-
0021526253
-
Preparation of Standard Vapor-Gas Mixtures for Gas Chromatography: Continuous Gas Extraction
-
Vitenberg A.G., Kostkina M.I., Ioffe B.V. Preparation of Standard Vapor-Gas Mixtures for Gas Chromatography Continuous Gas Extraction. Anal. Chem. 56:1984;2496-2500
-
(1984)
Anal. Chem.
, vol.56
, pp. 2496-2500
-
-
Vitenberg, A.G.1
Kostkina, M.I.2
Ioffe, B.V.3
-
11
-
-
0000923799
-
Membrane Introduction Mass Spectrometry
-
Kotiaho T., Lauritsen F.R., Choudhury T.K., Cooks R.G., Tsao G.T. Membrane Introduction Mass Spectrometry. Anal. Chem. 63:1991;875A-883A
-
(1991)
Anal. Chem.
, vol.63
-
-
Kotiaho, T.1
Lauritsen, F.R.2
Choudhury, T.K.3
Cooks, R.G.4
Tsao, G.T.5
-
12
-
-
0001420194
-
A New Membrane Inlet for On-Line Monitoring of Dissolved, Volatile Organic Compounds with Mass Spectrometry
-
Lauritsen F.R. A New Membrane Inlet for On-Line Monitoring of Dissolved, Volatile Organic Compounds with Mass Spectrometry. Int. J. Mass Spectrom. Ion Processes. 95:1990;168-259
-
(1990)
Int. J. Mass Spectrom. Ion Processes
, vol.95
, pp. 168-259
-
-
Lauritsen, F.R.1
-
13
-
-
30844462369
-
Time- and Concentration-Dependent Relative Peak Intensities Observed in Electron Impact Membrane Inlet Mass Spectra
-
Hansen K.F., Gylling S., Lauritsen F.R. Time- and Concentration-Dependent Relative Peak Intensities Observed in Electron Impact Membrane Inlet Mass Spectra. Int. J. Mass Spectrom. Ion Processes. 152:1996;143-155
-
(1996)
Int. J. Mass Spectrom. Ion Processes
, vol.152
, pp. 143-155
-
-
Hansen, K.F.1
Gylling, S.2
Lauritsen, F.R.3
|