메뉴 건너뛰기




Volumn 76, Issue 4, 2005, Pages 550-554

Impaction bone grafting with hydroxyapatite: Increased femoral component stability in experiments using Sawbones

Author keywords

[No Author keywords available]

Indexed keywords

HYDROXYAPATITE;

EID: 24144455952     PISSN: 17453674     EISSN: None     Source Type: Journal    
DOI: 10.1080/17453670510041556     Document Type: Article
Times cited : (21)

References (19)
  • 1
    • 0036051518 scopus 로고    scopus 로고
    • Subsidence in impaction grafting: The effect of adding a ceramic bone graft extender to bone
    • Blom A W, Grimm B, Miles A W, Cunningham J L, Learmonth I D. Subsidence in impaction grafting: the effect of adding a ceramic bone graft extender to bone. Proc Inst Mech Eng [H] 2002; 216 (4): 265-70.
    • (2002) Proc Inst Mech Eng [H] , vol.216 , Issue.4 , pp. 265-270
    • Blom, A.W.1    Grimm, B.2    Miles, A.W.3    Cunningham, J.L.4    Learmonth, I.D.5
  • 2
    • 0036132507 scopus 로고    scopus 로고
    • Acetabular defect reconstruction with impacted morsellized bone grafts or TCP/HA particles. A study on the mechanical stability of cemented cups in an artificial acetabulum model
    • Bolder S B, Verdonschot N, Schreurs B W, Buma P. Acetabular defect reconstruction with impacted morsellized bone grafts or TCP/HA particles. A study on the mechanical stability of cemented cups in an artificial acetabulum model. Biomaterials 2002; 23 (3): 659-66.
    • (2002) Biomaterials , vol.23 , Issue.3 , pp. 659-666
    • Bolder, S.B.1    Verdonschot, N.2    Schreurs, B.W.3    Buma, P.4
  • 3
    • 0346157398 scopus 로고    scopus 로고
    • The initial stability of cemented acetabular cups can be augmented by mixing morsellized bone grafts with tricalciumphosphate/hydroxyapatite particles in bone impaction grafting
    • Bolder S B, Verdonschot N, Schreurs B W, Buma P. The initial stability of cemented acetabular cups can be augmented by mixing morsellized bone grafts with tricalciumphosphate/hydroxyapatite particles in bone impaction grafting. J Arthroplasty 2003; 18 (8): 1056-63.
    • (2003) J Arthroplasty , vol.18 , Issue.8 , pp. 1056-1063
    • Bolder, S.B.1    Verdonschot, N.2    Schreurs, B.W.3    Buma, P.4
  • 9
    • 0042522391 scopus 로고    scopus 로고
    • Femoral impaction grafting with cement in revision total hip replacement. Evolution of the technique and results
    • Halliday B R, English H W, Timperley A J, Gie G A, Ling R S. Femoral impaction grafting with cement in revision total hip replacement. Evolution of the technique and results. J Bone Joint Surg (Br) 2003; 85 (6): 809-17.
    • (2003) J Bone Joint Surg (Br) , vol.85 , Issue.6 , pp. 809-817
    • Halliday, B.R.1    English, H.W.2    Timperley, A.J.3    Gie, G.A.4    Ling, R.S.5
  • 10
    • 0028365606 scopus 로고
    • Bone formation in coralline hydroxyapatite. Effects of pore size studied in rabbits
    • Kuhne J H, Bartl R, Frisch B, Hammer C, Jansson V, Zimmer M. Bone formation in coralline hydroxyapatite. Effects of pore size studied in rabbits. Acta Orthop Scand 1994; 65 (3): 246-52.
    • (1994) Acta Orthop Scand , vol.65 , Issue.3 , pp. 246-252
    • Kuhne, J.H.1    Bartl, R.2    Frisch, B.3    Hammer, C.4    Jansson, V.5    Zimmer, M.6
  • 11
    • 0033666122 scopus 로고    scopus 로고
    • Cancellous impaction grafting in the human femur: Histological and radiographic observations in 6 autopsy femurs and 8 biopsies
    • Linder L. Cancellous impaction grafting in the human femur: histological and radiographic observations in 6 autopsy femurs and 8 biopsies. Acta Orthop Scand 2000; 71 (6): 543-52.
    • (2000) Acta Orthop Scand , vol.71 , Issue.6 , pp. 543-552
    • Linder, L.1
  • 12
    • 0021718314 scopus 로고
    • Instability of total hip prostheses at rotational stress. A roentgen stereophotogrammetric study
    • Mjoberg B, Hansson L I, Selvik G. Instability of total hip prostheses at rotational stress. A roentgen stereophotogrammetric study. Acta Orthop Scand 1984; 55 (5): 504-6.
    • (1984) Acta Orthop Scand , vol.55 , Issue.5 , pp. 504-506
    • Mjoberg, B.1    Hansson, L.I.2    Selvik, G.3
  • 13
    • 0031026881 scopus 로고    scopus 로고
    • Hydroxyapatite in revision of total hip replacements with massive acetabular defects: 4- To 10-year clinical results
    • Oonishi H, Iwaki Y, Kin N, Kushitani S, Murata N, Wakitani S, Imoto, K. Hydroxyapatite in revision of total hip replacements with massive acetabular defects: 4- to 10-year clinical results. J Bone Joint Surg (Br) 1997; 79 (1): 87-92.
    • (1997) J Bone Joint Surg (Br) , vol.79 , Issue.1 , pp. 87-92
    • Oonishi, H.1    Iwaki, Y.2    Kin, N.3    Kushitani, S.4    Murata, N.5    Wakitani, S.6    Imoto, K.7
  • 14
    • 0033858254 scopus 로고    scopus 로고
    • Radiostereometric analysis in hip revision surgery-optimal time for index examination. 6 patients revised with impacted allografts and cement followed weekly for 6 weeks
    • Ornstein E, Franzen H, Johnsson R, Sundberg M. Radiostereometric analysis in hip revision surgery-optimal time for index examination. 6 patients revised with impacted allografts and cement followed weekly for 6 weeks. Acta Orthop Scand 2000; 71 (4): 360-4.
    • (2000) Acta Orthop Scand , vol.71 , Issue.4 , pp. 360-364
    • Ornstein, E.1    Franzen, H.2    Johnsson, R.3    Sundberg, M.4
  • 15
    • 0027223086 scopus 로고
    • Effects of femoral component material properties on cementless fixation in total hip arthroplasty. A comparison study between carbon composite, titanium alloy, and stainless steel
    • Otani T, Whiteside L A, White S E, McCarthy D S. Effects of femoral component material properties on cementless fixation in total hip arthroplasty. A comparison study between carbon composite, titanium alloy, and stainless steel. J Arthroplasty 1993; 8 (1): 67-74.
    • (1993) J Arthroplasty , vol.8 , Issue.1 , pp. 67-74
    • Otani, T.1    Whiteside, L.A.2    White, S.E.3    McCarthy, D.S.4
  • 16
    • 0024957650 scopus 로고
    • Examination of rotational fixation of the femoral component in total hip arthroplasty. A mechanical study of micromovement and acoustic emission
    • Sugiyama H, Whiteside L A, Kaiser A D. Examination of rotational fixation of the femoral component in total hip arthroplasty. A mechanical study of micromovement and acoustic emission. Clin Orthop 1989; (249): 122-8.
    • (1989) Clin Orthop , Issue.249 , pp. 122-128
    • Sugiyama, H.1    Whiteside, L.A.2    Kaiser, A.D.3
  • 17
    • 0019449271 scopus 로고
    • A study of the clinical incidence of infection in the use of banked allograft bone
    • Tomford W W, Starkweather R J, Goldman M H. A study of the clinical incidence of infection in the use of banked allograft bone. J Bone Joint Surg (Am) 1981; 63 (2): 244-8.
    • (1981) J Bone Joint Surg (Am) , vol.63 , Issue.2 , pp. 244-248
    • Tomford, W.W.1    Starkweather, R.J.2    Goldman, M.H.3
  • 18
    • 0031045696 scopus 로고    scopus 로고
    • Pore size of porous hydroxyapatite as the cell-substratum controls BMP-induced osteogenesis
    • Tsuruga E, Takita H, Itoh H, Wakisaka Y, Kuboki Y. Pore size of porous hydroxyapatite as the cell-substratum controls BMP-induced osteogenesis. J Biochem (Tokyo) 1997; 121 (2): 317-24.
    • (1997) J Biochem (Tokyo) , vol.121 , Issue.2 , pp. 317-324
    • Tsuruga, E.1    Takita, H.2    Itoh, H.3    Wakisaka, Y.4    Kuboki, Y.5
  • 19
    • 0034806932 scopus 로고    scopus 로고
    • Time-dependent mechanical properties of HA/TCP particles in relation to morsellized bone grafts for use in impaction grafting
    • Verdonschot N, van Hal C T, Schreurs B W, Buma P, Huiskes R, Slooff T J. Time-dependent mechanical properties of HA/TCP particles in relation to morsellized bone grafts for use in impaction grafting. J Biomed Mater Res 2001; 58 (5): 599-604.
    • (2001) J Biomed Mater Res , vol.58 , Issue.5 , pp. 599-604
    • Verdonschot, N.1    Van Hal, C.T.2    Schreurs, B.W.3    Buma, P.4    Huiskes, R.5    Slooff, T.J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.