Volumn 20, Issue 5, 2005, Pages 381-385

Intravenous myocardial contrast echocardiography for the diagnosis of coronary artery disease

Author keywords

Coronary artery disease; Myocardial contrast echocardiography; Perfusion

Indexed keywords

CONTRAST MEDIUM;

EID: 23944482964     PISSN: 02684705     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.hco.0000176404.48496.a2     Document Type: Review
Times cited : (11)

References (27)
  • 2
    • 0030811703 scopus 로고    scopus 로고
    • Coronary and myocardial blood volumes: Noninvasive tools to assess the coronary microcirculation?
    • Kaul S, Jayaweera AR. Coronary and myocardial blood volumes: noninvasive tools to assess the coronary microcirculation? Circulation 1997; 96:719-724.
    • (1997) Circulation , vol.96 , pp. 719-724
    • Kaul, S.1    Jayaweera, A.R.2
  • 3
    • 0028308410 scopus 로고
    • In vivo myocardial kinetics of air-filled albumin microbubbles during myocardial contrast echocardiography: Comparison with radiolabeled red blood cells
    • Jayaweera AR, Edwards N, Glasheen WP, et al. In vivo myocardial kinetics of air-filled albumin microbubbles during myocardial contrast echocardiography: comparison with radiolabeled red blood cells. Circ Res 1994; 74: 1157-1165.
    • (1994) Circ Res , vol.74 , pp. 1157-1165
    • Jayaweera, A.R.1    Edwards, N.2    Glasheen, W.P.3
  • 4
    • 0032127747 scopus 로고    scopus 로고
    • Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: Bolus or continuous infusion?
    • Wei K, Jayaweera AR, Firoozan S, et al. Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: bolus or continuous infusion? J Am Coll Cardiol 1998; 32:252-260.
    • (1998) J Am Coll Cardiol , vol.32 , pp. 252-260
    • Wei, K.1    Jayaweera, A.R.2    Firoozan, S.3
  • 5
    • 0032501992 scopus 로고    scopus 로고
    • Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion
    • Wei K, Jayaweera AR, Firoozan S, et al. Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. Circulation 1998; 97:473-483.
    • (1998) Circulation , vol.97 , pp. 473-483
    • Wei, K.1    Jayaweera, A.R.2    Firoozan, S.3
  • 6
    • 1042264292 scopus 로고    scopus 로고
    • Assessment of the physiologic significance of coronary disease with dipyridamole real-time myocardial contrast echocardiography: Comparison with technetium-99m sestamibi single-photon emission computed tomography and quantitative coronary angiography
    • Peltier M, Vancraeynest D, Pasquet A, et al. Assessment of the physiologic significance of coronary disease with dipyridamole real-time myocardial contrast echocardiography: comparison with technetium-99m sestamibi single-photon emission computed tomography and quantitative coronary angiography. J Am Coll Cardiol 2004; 43:257-264. An excellent study assessing the value of quantitative real-time MCE for detecting CAD.
    • (2004) J Am Coll Cardiol , vol.43 , pp. 257-264
    • Peltier, M.1    Vancraeynest, D.2    Pasquet, A.3
  • 7
    • 0030279882 scopus 로고    scopus 로고
    • Detection of myocardial perfusion abnormalities during dobutamine and adenosine stress echocardiography with transient myocardial contrast imaging after minute quantities of intravenous perfluorocarbon-exposed sonicated dextrose albumin
    • Porter TR, Xie F, Kilzer K, Deligonul U. Detection of myocardial perfusion abnormalities during dobutamine and adenosine stress echocardiography with transient myocardial contrast imaging after minute quantities of intravenous perfluorocarbon-exposed sonicated dextrose albumin. J Am Soc Echocardiogr 1996; 9:779-786.
    • (1996) J Am Soc Echocardiogr , vol.9 , pp. 779-786
    • Porter, T.R.1    Xie, F.2    Kilzer, K.3    Deligonul, U.4
  • 8
    • 0031812622 scopus 로고    scopus 로고
    • Correlation between quantitative angiographic lesion severity and myocardial contrast intensity during a continuous infusion of perfluorocarbon-containing microbubbles
    • Porter T, Li S, Kilzer K, Deligonul U. Correlation between quantitative angiographic lesion severity and myocardial contrast intensity during a continuous infusion of perfluorocarbon-containing microbubbles. J Am Soc Echocardiogr 1998; 11:702-710.
    • (1998) J Am Soc Echocardiogr , vol.11 , pp. 702-710
    • Porter, T.1    Li, S.2    Kilzer, K.3    Deligonul, U.4
  • 9
    • 0033373582 scopus 로고    scopus 로고
    • Role of capillaries in determining CBF reserve: New insights using myocardial contrast echocardiography
    • Jayaweera AR, Wei K, Coggins M, et al. Role of capillaries in determining CBF reserve: new insights using myocardial contrast echocardiography. Am J Physiol 1999; 277:H2363-H2372.
    • (1999) Am J Physiol , vol.277
    • Jayaweera, A.R.1    Wei, K.2    Coggins, M.3
  • 10
    • 0030792911 scopus 로고    scopus 로고
    • Detection of coronary artery disease with myocardial contrast echocardiography: Comparison with 99mTc-sestamibi single-photon emission computed tomography
    • Kaul S, Senior R, Dittrich H, et al. Detection of coronary artery disease with myocardial contrast echocardiography: comparison with 99mTc-sestamibi single-photon emission computed tomography. Circulation 1997; 96:785-792.
    • (1997) Circulation , vol.96 , pp. 785-792
    • Kaul, S.1    Senior, R.2    Dittrich, H.3
  • 11
    • 0035282050 scopus 로고    scopus 로고
    • Real-time perfusion imaging with low mechanical index pulse inversion Doppler imaging
    • Porter TR, Xie F, Silver M, et al. Real-time perfusion imaging with low mechanical index pulse inversion Doppler imaging. J Am Coll Cardiol 2001; 37: 748-753.
    • (2001) J Am Coll Cardiol , vol.37 , pp. 748-753
    • Porter, T.R.1    Xie, F.2    Silver, M.3
  • 12
    • 9644272606 scopus 로고    scopus 로고
    • Comparative accuracy of real-time myocardial contrast perfusion imaging and wall motion analysis during dobutamine stress echocardiography for the diagnosis of coronary artery disease
    • Elhendy A, O'leary EL, Xie F, et al. Comparative accuracy of real-time myocardial contrast perfusion imaging and wall motion analysis during dobutamine stress echocardiography for the diagnosis of coronary artery disease. J Am Coll Cardiol 2004; 44:2185-2191. An important study demonstrating the diagnostic accuracy of real-time MCE in 170 patients who underwent quantitative coronary angiography.
    • (2004) J Am Coll Cardiol , vol.44 , pp. 2185-2191
    • Elhendy, A.1    O'Leary, E.L.2    Xie, F.3
  • 13
    • 0034604241 scopus 로고    scopus 로고
    • Assessment of myocardial perfusion by harmonic power Doppler imaging at rest and during adenosine stress: Comparison with (99m)Tc-sestamibi SPECT imaging
    • Heinle SK, Noblin J, Goree-Best P, et al. Assessment of myocardial perfusion by harmonic power Doppler imaging at rest and during adenosine stress: comparison with (99m)Tc-sestamibi SPECT imaging. Circulation 2000; 102: 55-60.
    • (2000) Circulation , vol.102 , pp. 55-60
    • Heinle, S.K.1    Noblin, J.2    Goree-Best, P.3
  • 14
    • 3042770848 scopus 로고    scopus 로고
    • Myocardial perfusion assessment in patients with medium probability of coronary artery disease and no prior myocardial infarction: Comparison of myocardial contrast echocardiography with 99mTc single-photon emission computed tomography
    • Senior R, Lepper W, Pasquet A, et al. Myocardial perfusion assessment in patients with medium probability of coronary artery disease and no prior myocardial infarction: comparison of myocardial contrast echocardiography with 99mTc single-photon emission computed tomography. Am Heart J 2004; 147:1100-1105. This paper outlines the value of myocardial contrast echocardiography for detecting CAD in comparison with nuclear medicine.
    • (2004) Am Heart J , vol.147 , pp. 1100-1105
    • Senior, R.1    Lepper, W.2    Pasquet, A.3
  • 15
    • 13844297656 scopus 로고    scopus 로고
    • Comparison of low-mechanical index pulse sequence schemes for detecting myocardial perfusion abnormalities during vasodilator stress echocardiography
    • Tsutsui JM, Xie F, McGrain AC, et al. Comparison of low-mechanical index pulse sequence schemes for detecting myocardial perfusion abnormalities during vasodilator stress echocardiography. Am J Cardiol 2005; 95: 565-570. This important study compares triggered replenishment imaging with real-time perfusion imaging for detecting patients with perfusion abnormalities.
    • (2005) Am J Cardiol , vol.95 , pp. 565-570
    • Tsutsui, J.M.1    Xie, F.2    McGrain, A.C.3
  • 16
    • 2442466974 scopus 로고    scopus 로고
    • Incremental value of parametric quantitative assessment of myocardial perfusion by triggered low-power myocardial contrast echocardiography
    • Yu EH, Skyba DM, Leong-Poi H, et al. Incremental value of parametric quantitative assessment of myocardial perfusion by triggered low-power myocardial contrast echocardiography. J Am Coll Cardiol 2004; 43: 1807-1813. This is an interesting study demonstrating that the analysis of myocardial parametric quantification had better agreement with SPECT than visual analysis alone.
    • (2004) J Am Coll Cardiol , vol.43 , pp. 1807-1813
    • Yu, E.H.1    Skyba, D.M.2    Leong-Poi, H.3
  • 17
    • 0031182603 scopus 로고    scopus 로고
    • The effect of ultrasound frame rate on perfluorocarbon-exposed sonicated dextrose albumin microbubble size and concentration when insonifying at different flow rates, transducer frequencies, and acoustic outputs
    • Porter TR, Kricsfeld D, Cheatham S, Li S. The effect of ultrasound frame rate on perfluorocarbon-exposed sonicated dextrose albumin microbubble size and concentration when insonifying at different flow rates, transducer frequencies, and acoustic outputs. J Am Soc Echocardiogr 1997; 10:593-601.
    • (1997) J Am Soc Echocardiogr , vol.10 , pp. 593-601
    • Porter, T.R.1    Kricsfeld, D.2    Cheatham, S.3    Li, S.4
  • 18
    • 0035967485 scopus 로고    scopus 로고
    • Noninvasive quantification of coronary blood flow reserve in humans using myocardial contrast echocardiography
    • Wei K, Ragosta M, Thorpe J, et al. Noninvasive quantification of coronary blood flow reserve in humans using myocardial contrast echocardiography. Circulation 2001; 103:2560-2565.
    • (2001) Circulation , vol.103 , pp. 2560-2565
    • Wei, K.1    Ragosta, M.2    Thorpe, J.3
  • 19
    • 15244355001 scopus 로고    scopus 로고
    • Usefulness of myocardial perfusion echocardiography to identify obstructive coronary artery disease in patients with abnormal ventricular septal motion
    • Spevack DM, Shoyeb A, Yoon AJ, et al. Usefulness of myocardial perfusion echocardiography to identify obstructive coronary artery disease in patients with abnormal ventricular septal motion. Am J Cardiol 2005; 95:852-855. The importance of this study consists in demonstrating the value of quantitative MCE for identifying CAD in a specific population of patients with otherwise confounding diagnosis.
    • (2005) Am J Cardiol , vol.95 , pp. 852-855
    • Spevack, D.M.1    Shoyeb, A.2    Yoon, A.J.3
  • 20
    • 0035943072 scopus 로고    scopus 로고
    • Destruction of contrast microbubbles by ultrasound: Effects on myocardial function, coronary perfusion pressure, and microvascular integrity
    • Ay T, Havaux X, Van CG, et al. Destruction of contrast microbubbles by ultrasound: effects on myocardial function, coronary perfusion pressure, and microvascular integrity. Circulation 2001; 104:461-466.
    • (2001) Circulation , vol.104 , pp. 461-466
    • Ay, T.1    Havaux, X.2    Van, C.G.3
  • 21
    • 0035185644 scopus 로고    scopus 로고
    • Effectiveness of transcranial and transthoracic ultrasound and microbubbles in dissolving intravascular thrombi
    • Porter TR, Kricsfeld D, Lof J, et al. Effectiveness of transcranial and transthoracic ultrasound and microbubbles in dissolving intravascular thrombi. J Ultrasound Med 2001; 20:1313-1325.
    • (2001) J Ultrasound Med , vol.20 , pp. 1313-1325
    • Porter, T.R.1    Kricsfeld, D.2    Lof, J.3
  • 22
    • 0034004696 scopus 로고    scopus 로고
    • Premature ventricular contractions during triggered imaging with ultrasound contrast
    • van Der Wouw PA, Brauns AC, Bailey SE, et al. Premature ventricular contractions during triggered imaging with ultrasound contrast. J Am Soc Echocardiogr 2000; 13:288-294.
    • (2000) J Am Soc Echocardiogr , vol.13 , pp. 288-294
    • Van Der Wouw, P.A.1    Brauns, A.C.2    Bailey, S.E.3
  • 23
    • 10744228375 scopus 로고    scopus 로고
    • Myocardial contrast echocardiography (MCE) with triggered ultrasound does not cause premature ventricular complexes: Evidence from PB127 MCE studies
    • Raisinghani A, Wei KS, Grouse L, et al. Myocardial contrast echocardiography (MCE) with triggered ultrasound does not cause premature ventricular complexes: evidence from PB127 MCE studies. J Am Soc Echocardiogr 2003; 16:1037-1042.
    • (2003) J Am Soc Echocardiogr , vol.16 , pp. 1037-1042
    • Raisinghani, A.1    Wei, K.S.2    Grouse, L.3
  • 24
    • 17144371517 scopus 로고    scopus 로고
    • Safety of dobutamine stress real-time myocardial contrast echocardiography
    • Tsutsui JM, Elhendy A, Xie F, et al. Safety of dobutamine stress real-time myocardial contrast echocardiography. J Am Coll Cardiol 2005; 45: 1235-1242. This study demonstrated, in a large cohort of patients, that real-time MCE is a safe, feasible, and accurate method for evaluating patients with suspected CAD.
    • (2005) J Am Coll Cardiol , vol.45 , pp. 1235-1242
    • Tsutsui, J.M.1    Elhendy, A.2    Xie, F.3
  • 25
    • 0035282040 scopus 로고    scopus 로고
    • Real-time assessment of myocardial perfusion and wall motion during bicycle and treadmill exercise echocardiography: Comparison with single photon emission computed tomography
    • Shimoni S, Zoghbi WA, Xie F, et al. Real-time assessment of myocardial perfusion and wall motion during bicycle and treadmill exercise echocardiography: comparison with single photon emission computed tomography. J Am Coll Cardiol 2001; 37:741-747.
    • (2001) J Am Coll Cardiol , vol.37 , pp. 741-747
    • Shimoni, S.1    Zoghbi, W.A.2    Xie, F.3
  • 26
    • 4444268575 scopus 로고    scopus 로고
    • Comparison of real-time myocardial contrast echocardiography for the assessment of myocardial viability with flourodeoxyglucose-18 positron emission tomography and dobutamine stress echocardiography
    • Korosoglou G, Hansen A, Hoffend J, et al. Comparison of real-time myocardial contrast echocardiography for the assessment of myocardial viability with flourodeoxyglucose-18 positron emission tomography and dobutamine stress echocardiography. Am J Cardiol 2004; 94:570-576.
    • (2004) Am J Cardiol , vol.94 , pp. 570-576
    • Korosoglou, G.1    Hansen, A.2    Hoffend, J.3
  • 27
    • 20244379111 scopus 로고    scopus 로고
    • Usefulness of real-time myocardial perfusion imaging to evaluate tissue level reperfusion in patients with non-ST-elevation myocardial infarction
    • Korosoglou G, Labadze N, Giannitsis E, et al. Usefulness of real-time myocardial perfusion imaging to evaluate tissue level reperfusion in patients with non-ST-elevation myocardial infarction. Am J Cardiol 2005; 95:1033-1038.
    • (2005) Am J Cardiol , vol.95 , pp. 1033-1038
    • Korosoglou, G.1    Labadze, N.2    Giannitsis, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.