-
1
-
-
0034953614
-
The use of cuffed endotracheal tubes in infants and small children
-
Erb T, Frei FJ. The use of cuffed endotracheal tubes in infants and small children. Anaesthesist 2001; 50: 395-400.
-
(2001)
Anaesthesist
, vol.50
, pp. 395-400
-
-
Erb, T.1
Frei, F.J.2
-
2
-
-
0034762153
-
Cuffed tubes in children: A 3-year experience in a single institution
-
Murat I. Cuffed tubes in children: a 3-year experience in a single institution. Paediatr Anaesth 2001; 11: 748-9.
-
(2001)
Paediatr Anaesth
, vol.11
, pp. 748-749
-
-
Murat, I.1
-
3
-
-
0035031240
-
Postal survey of cuffed or uncuffed tracheal tubes used for paediatric tracheal intubation
-
Orliaguet GA, Renaud E, Lejay M et al. Postal survey of cuffed or uncuffed tracheal tubes used for paediatric tracheal intubation. Paediatr Anaesth 2001; 11: 277-81.
-
(2001)
Paediatr Anaesth
, vol.11
, pp. 277-281
-
-
Orliaguet, G.A.1
Renaud, E.2
Lejay, M.3
-
4
-
-
0030942862
-
Comparison of cuffed and uncuffed endotracheal tubes in young children during general anesthesia
-
Khine HH, Corddry DH, Kettrick RG et al. Comparison of cuffed and uncuffed endotracheal tubes in young children during general anesthesia. Anesthesiology 1997; 86: 627-31.
-
(1997)
Anesthesiology
, vol.86
, pp. 627-631
-
-
Khine, H.H.1
Corddry, D.H.2
Kettrick, R.G.3
-
5
-
-
0345714996
-
Endotracheal tube cuff pressure is unpredictable in children
-
Felten ML, Schmautz E, Delaporte-Cerceau S, Orliaguet GA, Carli PA. Endotracheal tube cuff pressure is unpredictable in children. Anesth Analg 2003; 97: 1612-6.
-
(2003)
Anesth Analg
, vol.97
, pp. 1612-1616
-
-
Felten, M.L.1
Schmautz, E.2
Delaporte-Cerceau, S.3
Orliaguet, G.A.4
Carli, P.A.5
-
6
-
-
0025875334
-
Endotracheal tube cuff pressure in the use of nitrous oxide
-
Fischer CG, Cook DR. Endotracheal tube cuff pressure in the use of nitrous oxide. Anesth Analg 1991; 73: 99.
-
(1991)
Anesth Analg
, vol.73
, pp. 99
-
-
Fischer, C.G.1
Cook, D.R.2
-
7
-
-
0033632456
-
2O and endotracheal cuff pressure
-
2O and endotracheal cuff pressure. Anesth Analg 2000; 90: 230.
-
(2000)
Anesth Analg
, vol.90
, pp. 230
-
-
Priebe, H.J.1
-
8
-
-
0013434707
-
The cuff
-
Vaughan, R, ed. London: W. B. Saunders
-
Latto P. The cuff. In: Vaughan, R, ed. Difficulties in Tracheal Intubation. London: W. B. Saunders, 1997: 51-78.
-
(1997)
Difficulties in Tracheal Intubation
, pp. 51-78
-
-
Latto, P.1
-
9
-
-
33645439607
-
Tubes with cuffs in newborn and young children are a risk! Remarks on the paper by T. Erb and F. J. Frei
-
Holzki J. [Tubes with cuffs in newborn and young children are a risk! Remarks on the paper by T. Erb and F. J. Frei, Anaesthesist 2001 50: 395-400].
-
(2001)
Anaesthesist
, vol.50
, pp. 395-400
-
-
Holzki, J.1
-
10
-
-
0036235126
-
-
author reply 5-6
-
Anaesthesist 2002; 51: 321-3; author reply 5-6.
-
(2002)
Anaesthesist
, vol.51
, pp. 321-323
-
-
-
11
-
-
0019817946
-
Effects of nitrous oxide and oxygen on tracheal tube cuff gas volumes
-
Mehta S. Effects of nitrous oxide and oxygen on tracheal tube cuff gas volumes. Br J Anaesth 1981; 53: 1227-31.
-
(1981)
Br J Anaesth
, vol.53
, pp. 1227-1231
-
-
Mehta, S.1
-
12
-
-
85056015691
-
Greater caution using tubes with cuffs. Remarks on the paper 'The use of cuffed endotracheal tubes in infants and small children' by T. Erb and F. J. Frei
-
Hoeve LJ. [Greater caution using tubes with cuffs. Remarks on the paper 'The use of cuffed endotracheal tubes in infants and small children' by T. Erb and F. J. Frei, Anaesthesist 2001; 50: 395-400].
-
(2001)
Anaesthesist
, vol.50
, pp. 395-400
-
-
Hoeve, L.J.1
-
13
-
-
33645437924
-
-
Anaesthesist 2002; 51: 320; 5-6.
-
(2002)
Anaesthesist
, vol.320
, Issue.51
, pp. 5-6
-
-
-
15
-
-
0032882439
-
A cuff pressure controller for tracheal tubes and laryngeal mask airways
-
Abdelatti MO. A cuff pressure controller for tracheal tubes and laryngeal mask airways. Anaesthesia 1999; 54: 981-6.
-
(1999)
Anaesthesia
, vol.54
, pp. 981-986
-
-
Abdelatti, M.O.1
-
16
-
-
0032883660
-
A simple method to control tracheal cuff pressure in anaesthesia and in air evacuation
-
Yoneda I, Watanabe K, Hayashida S, Kanno M, Sato T. A simple method to control tracheal cuff pressure in anaesthesia and in air evacuation. Anaesthesia 1999; 54: 975-80.
-
(1999)
Anaesthesia
, vol.54
, pp. 975-980
-
-
Yoneda, I.1
Watanabe, K.2
Hayashida, S.3
Kanno, M.4
Sato, T.5
-
17
-
-
0023881963
-
Tracheal tube cuff pressure. Clinical use of the Cardiff Cuff Controller
-
Willis BA, Latto IP, Dyson A. Tracheal tube cuff pressure. Clinical use of the Cardiff Cuff Controller. Anaesthesia 1988; 43: 312-4.
-
(1988)
Anaesthesia
, vol.43
, pp. 312-314
-
-
Willis, B.A.1
Latto, I.P.2
Dyson, A.3
-
18
-
-
0022122163
-
An electropneumatic instrument for measuring and controlling the pressures in the cuffs of tracheal tubes: 'The Cardiff Cuff Controller'
-
Morris JV, Latto IP. An electropneumatic instrument for measuring and controlling the pressures in the cuffs of tracheal tubes: 'the Cardiff Cuff Controller'. J Med Eng Technol 1985; 9: 229-30.
-
(1985)
J Med Eng Technol
, vol.9
, pp. 229-230
-
-
Morris, J.V.1
Latto, I.P.2
-
19
-
-
0020073741
-
Sore throat after operation: Influence of tracheal intubation, intracuff pressure and type of cuff
-
Jensen PJ, Hommelgaard P, Sondergaard P, Eriksen S. Sore throat after operation: influence of tracheal intubation, intracuff pressure and type of cuff. Br J Anaesth 1982; 54: 453-7.
-
(1982)
Br J Anaesth
, vol.54
, pp. 453-457
-
-
Jensen, P.J.1
Hommelgaard, P.2
Sondergaard, P.3
Eriksen, S.4
-
20
-
-
0026682956
-
A pressure regulator for the cuff of a tracheal tube
-
Miller DM. A pressure regulator for the cuff of a tracheal tube. Anaesthesia 1992; 47: 594-6.
-
(1992)
Anaesthesia
, vol.47
, pp. 594-596
-
-
Miller, D.M.1
-
22
-
-
0032711791
-
Evaluation of pressure changes in a new design tracheal tube cuff, the Portex Soft Seal, during nitrous oxide anaesthesia
-
Al-Shaikh B, Jones M, Baldwin F. Evaluation of pressure changes in a new design tracheal tube cuff, the Portex Soft Seal, during nitrous oxide anaesthesia. Br J Anaesth 1999; 83: 805-6.
-
(1999)
Br J Anaesth
, vol.83
, pp. 805-806
-
-
Al-Shaikh, B.1
Jones, M.2
Baldwin, F.3
-
23
-
-
0028799830
-
A new endotracheal tube with a cuff impervious to nitrous oxide: Constancy of cuff pressure and volume
-
Fujiwara M, Mizoguchi H, Kawamura J et al. A new endotracheal tube with a cuff impervious to nitrous oxide: constancy of cuff pressure and volume. Anesth Analg 1995; 81: 1084-6.
-
(1995)
Anesth Analg
, vol.81
, pp. 1084-1086
-
-
Fujiwara, M.1
Mizoguchi, H.2
Kawamura, J.3
-
24
-
-
0035172679
-
Profile soft-seal cuff, a new endotracheal tube, effectively inhibits an increase in the cuff pressure through high compliance rather than low diffusion of nitrous oxide
-
Karasawa F, Mori T, Okuda T, Satoh T. Profile soft-seal cuff, a new endotracheal tube, effectively inhibits an increase in the cuff pressure through high compliance rather than low diffusion of nitrous oxide. Anesth Analg 2001; 92: 140-4.
-
(2001)
Anesth Analg
, vol.92
, pp. 140-144
-
-
Karasawa, F.1
Mori, T.2
Okuda, T.3
Satoh, T.4
|