메뉴 건너뛰기




Volumn 33, Issue 3, 2005, Pages 329-341

Urea biosensors based on PVC membrane containing palmitic acid

Author keywords

Carboxylated polyvinylchloride; Nonactin; Palmitic acid; Polyvinylchloride; Urea

Indexed keywords

ASSAYS; BIOLOGICAL MEMBRANES; CARBOXYLATION; CELL IMMOBILIZATION; CELLS; ELECTRODES; ENZYMES; POLYVINYL CHLORIDES; UREA;

EID: 23944439992     PISSN: 10731199     EISSN: None     Source Type: Journal    
DOI: 10.1081/BIO-200066632     Document Type: Article
Times cited : (24)

References (26)
  • 1
    • 0029939109 scopus 로고    scopus 로고
    • Polypyrrole-based amperometric flow injection biosensor for urea
    • Adeloju, S.B., Shaw, S.J., Wallace, G.G. (1996). Polypyrrole-based amperometric flow injection biosensor for urea. Anal. Chim. Acta. 323: 107-113.
    • (1996) Anal. Chim. Acta , vol.323 , pp. 107-113
    • Adeloju, S.B.1    Shaw, S.J.2    Wallace, G.G.3
  • 2
    • 84963476581 scopus 로고
    • Enzyme urea biosensor based on a modified potentiometric PVC-nonactin membrane electrode for assay of urea in blood
    • Butt, S.B., Camman, K. (1992). Enzyme urea biosensor based on a modified potentiometric PVC-nonactin membrane electrode for assay of urea in blood. Anal. Lett. 25(9): 1597-1615.
    • (1992) Anal. Lett. , vol.25 , Issue.9 , pp. 1597-1615
    • Butt, S.B.1    Camman, K.2
  • 4
    • 0023330698 scopus 로고
    • Response of an enzyme-modified pH-sensitive ion-selective device: Analytical solution for the response in the presence of pH buffer
    • Eddowes, M.J. (1987). Response of an enzyme-modified pH-sensitive ion-selective device: analytical solution for the response in the presence of pH buffer. Sensors and Actuators. 11: 265-274.
    • (1987) Sensors and Actuators , vol.11 , pp. 265-274
    • Eddowes, M.J.1
  • 7
    • 72949127206 scopus 로고
    • A rapid and precise method for the determination of urea
    • Fawcett, F.K., Scott, J.E. (1960). A rapid and precise method for the determination of urea. J. Clin. Pathol. 13: 156-160.
    • (1960) J. Clin. Pathol. , vol.13 , pp. 156-160
    • Fawcett, F.K.1    Scott, J.E.2
  • 9
    • 33947294012 scopus 로고
    • An enzyme electrode for the substrate urea
    • Guilbault, G.G., Montalvo, J.G. (1970). An enzyme electrode for the substrate urea. J. Am. Chem. Soc. 92: 2533-8.
    • (1970) J. Am. Chem. Soc. , vol.92 , pp. 2533-2538
    • Guilbault, G.G.1    Montalvo, J.G.2
  • 10
    • 0002530715 scopus 로고
    • Enzyme sensor system for potentiometric urea determination in serum and milk
    • Hamann, H., Kühn, M., Böttcher, N., Scheller, F. (1986). Enzyme sensor system for potentiometric urea determination in serum and milk. J. Electroanal. Chem. 209: 69-79.
    • (1986) J. Electroanal. Chem. , vol.209 , pp. 69-79
    • Hamann, H.1    Kühn, M.2    Böttcher, N.3    Scheller, F.4
  • 12
    • 46149139707 scopus 로고
    • A microsensor for urea based on an ion-selective field effect transistor
    • Karube, I., Tamiya, E., Dicks, J.M. (1986). A microsensor for urea based on an ion-selective field effect transistor. Anal. Chim. Acta. 185: 195-200.
    • (1986) Anal. Chim. Acta , vol.185 , pp. 195-200
    • Karube, I.1    Tamiya, E.2    Dicks, J.M.3
  • 13
    • 0028093692 scopus 로고
    • Comparison of pH-membrane enzyme electrode for urea with covalently bound enzyme
    • Koncki, R., Kopczewska, E., Glab, S. (1994). Comparison of pH-membrane enzyme electrode for urea with covalently bound enzyme. Anal. Lett. 27(3): 475-486.
    • (1994) Anal. Lett. , vol.27 , Issue.3 , pp. 475-486
    • Koncki, R.1    Kopczewska, E.2    Glab, S.3
  • 14
    • 0026556776 scopus 로고
    • Urea sensor based on glass pH electrodes with physically immobilized urease
    • Koncki, R., Leszcynski, P., Hulanicki, A., Glab, S. (1992). Urea sensor based on glass pH electrodes with physically immobilized urease. Anal. Chim. Acta. 257: 67-72.
    • (1992) Anal. Chim. Acta , vol.257 , pp. 67-72
    • Koncki, R.1    Leszcynski, P.2    Hulanicki, A.3    Glab, S.4
  • 15
    • 0030575950 scopus 로고    scopus 로고
    • Bienzymatic potantiometric electrodes for creatine and L-arginine determination
    • Koncki, R., Walcerz , I., Ruckruh, F., Glab, S. (1996). Bienzymatic potantiometric electrodes for creatine and L-arginine determination. Anal. Chim. Acta. 333: 215-222.
    • (1996) Anal. Chim. Acta , vol.333 , pp. 215-222
    • Koncki, R.1    Walcerz, I.2    Ruckruh, F.3    Glab, S.4
  • 17
    • 0023118884 scopus 로고
    • Development and characterization of a polymer gel with an immobilized enzyme to measure L-Glutamate
    • Korenbrot, J.I., Perry, R., Copenhagen, D.R. (1987). Development and characterization of a polymer gel with an immobilized enzyme to measure L-Glutamate. Anal. Biochem. 161: 187-99.
    • (1987) Anal. Biochem. , vol.161 , pp. 187-199
    • Korenbrot, J.I.1    Perry, R.2    Copenhagen, D.R.3
  • 18
    • 0032170809 scopus 로고    scopus 로고
    • Urea potentiometric biosensor based on urease immobilized on chitosan membreanes
    • Magalhaes, J.M.C.S., Machado, A.A.S.C. (1998). Urea potentiometric biosensor based on urease immobilized on chitosan membreanes. Talanta. 47: 183-191.
    • (1998) Talanta , vol.47 , pp. 183-191
    • Magalhaes, J.M.C.S.1    Machado, A.A.S.C.2
  • 19
    • 0022026038 scopus 로고
    • Integrated enzyme FETs for simultaneous determination of urea and glucose
    • Miyahara, Y., Moriizumi, T., Ichimura, K. (1985). Integrated enzyme FETs for simultaneous determination of urea and glucose. Sensors Actuators 7: 1-10.
    • (1985) Sensors Actuators , vol.7 , pp. 1-10
    • Miyahara, Y.1    Moriizumi, T.2    Ichimura, K.3
  • 21
    • 0034733263 scopus 로고    scopus 로고
    • Potentiometric sensors: Aspects of the recent development
    • Ru-Qin, Y., Zong-Rang, Z., Guo-Li, S. (2000). Potentiometric sensors: aspects of the recent development. Sensors Actuators B. 65: 150-153.
    • (2000) Sensors Actuators B , vol.65 , pp. 150-153
    • Ru-Qin, Y.1    Zong-Rang, Z.2    Guo-Li, S.3
  • 22
    • 0018434019 scopus 로고
    • Enzyme determination of urea in serum based on pH measurement with the flow injection method
    • Ruzicka, J., Hansen, E.H., Ghose, A.K., Mottola, H.A. (1979). Enzyme determination of urea in serum based on pH measurement with the flow injection method. Anal. Chem. 51: 199-203.
    • (1979) Anal. Chem. , vol.51 , pp. 199-203
    • Ruzicka, J.1    Hansen, E.H.2    Ghose, A.K.3    Mottola, H.A.4
  • 23
    • 0033598186 scopus 로고    scopus 로고
    • A miniaturized urea based on the integration of both ammonium based urea enzyme field effect transistor and a reference field effect transistor in a single chip
    • Senillou, A., Jaffrezic-Renault, N., Martelet, C., Cosnier, S. (1999). A miniaturized urea based on the integration of both ammonium based urea enzyme field effect transistor and a reference field effect transistor in a single chip. Talanta. 50: 219-226.
    • (1999) Talanta , vol.50 , pp. 219-226
    • Senillou, A.1    Jaffrezic-Renault, N.2    Martelet, C.3    Cosnier, S.4
  • 25
    • 0039563813 scopus 로고
    • Determination of urea in blood plasma by enzyme-pH electrode
    • Vadgama, P.M., Alberti, K.G.M.M., Covington, A.K. (1982). Determination of urea in blood plasma by enzyme-pH electrode. Anal. Chim. Acta. 136: 403-6.
    • (1982) Anal. Chim. Acta , vol.136 , pp. 403-406
    • Vadgama, P.M.1    Alberti, K.G.M.M.2    Covington, A.K.3
  • 26
    • 2542632141 scopus 로고    scopus 로고
    • Enzyme biosensors for urea determination based on an ionophore free membrane electrode
    • Walcerz, I., Koncki, R., Leszczynska, E., Salamonowicz, B., Glab, S. (1996). Enzyme biosensors for urea determination based on an ionophore free membrane electrode. Anal. Lett. 29(11): 1939-1953.
    • (1996) Anal. Lett. , vol.29 , Issue.11 , pp. 1939-1953
    • Walcerz, I.1    Koncki, R.2    Leszczynska, E.3    Salamonowicz, B.4    Glab, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.