Volumn 5745, Issue II, 2005, Pages 943-951

Cone-beam CT breast imaging with a flat panel detector - A simulation study

Author keywords

Breast imaging; Calcifications; Cone beam breast CT; Detector blurring; Digital mammography; Flat panel detector; Masses; Noise

Indexed keywords

BREAST IMAGING; CONE-BEAM BREAST CT; DETECTOR BLURRING; DIGITAL MAMMOGRAPHY; FLAT PANEL DETECTORS; MASSES;

EID: 23844518400     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.597065     Document Type: Conference Paper
Times cited : (23)

References (8)
  • 1
    • 0035190741 scopus 로고    scopus 로고
    • Dedicated breast CT: Radiation dose and image quality evaluation
    • Boone, J.M., T.R. Nelson, and K.K. Lindfors, Dedicated Breast CT: Radiation Dose and Image Quality Evaluation. Radiology, 2001. 221(3): p. 657-667.
    • (2001) Radiology , vol.221 , Issue.3 , pp. 657-667
    • Boone, J.M.1    Nelson, T.R.2    Lindfors, K.K.3
  • 2
    • 0036033581 scopus 로고    scopus 로고
    • Investigation of optimal kVp settings for CT mammography using a flat panel detector
    • Glick, S., S. Vedantham, and A. Karellas, Investigation of optimal kVp Settings for CT mammography using a flat panel detector. SPIE, 2003. 4682: p. 392-402.
    • (2003) SPIE , vol.4682 , pp. 392-402
    • Glick, S.1    Vedantham, S.2    Karellas, A.3
  • 3
    • 0034860959 scopus 로고    scopus 로고
    • Flat panel detector-based cone beam volume CT mammography imaging: Preliminary phantom study
    • R Ning, B.C., D Conover, L McHugh, J Cullinan and R Yu, Flat panel detector-based cone beam volume CT mammography imaging: Preliminary phantom study. SPIE, 2001. 4320: p. 601-610.
    • (2001) SPIE , vol.4320 , pp. 601-610
    • Ning, R.1    Conover, D.2    C., B.3    McHugh, L.4    Cullinan, J.5    Yu, R.6
  • 4
    • 0035999405 scopus 로고    scopus 로고
    • Cone-beam volume CT breast imaging: Feasibility study
    • Chen, B. and R. Ning, Cone-beam volume CT breast imaging: Feasibility study. Med. Phys, 2002. 29(5): p. 755-770.
    • (2002) Med. Phys , vol.29 , Issue.5 , pp. 755-770
    • Chen, B.1    Ning, R.2
  • 5
    • 1242316319 scopus 로고    scopus 로고
    • CT Coefficients for pendant-geometry cone-beam breast computed tomography
    • CT Coefficients for pendant-geometry cone-beam breast computed tomography. Med. Phys., 2004. 31(2): p. 226-235.
    • (2004) Med. Phys. , vol.31 , Issue.2 , pp. 226-235
    • Boone, J.M.1    Shan, N.2    Nelson, T.R.3
  • 8
    • 1642576991 scopus 로고    scopus 로고
    • A-Si:H/CsI(TI) flat-panel versus computed radiography for chest imaging applications: Image quality metrics measurement
    • Liu, X. and C.C. Shaw, a-Si:H/CsI(TI) flat-panel versus computed radiography for chest imaging applications: image quality metrics measurement. Med. Phys., 2004. 31(1): p. 98-110.
    • (2004) Med. Phys. , vol.31 , Issue.1 , pp. 98-110
    • Liu, X.1    Shaw, C.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.