메뉴 건너뛰기




Volumn 52, Issue 3 I, 2005, Pages 573-579

Small animal imaging by single photon emission using pinhole and coded aperture collimation

Author keywords

Nuclear imaging; Scintillation detectors; Sensitivity; Spatial resolution

Indexed keywords

AMINO ACIDS; ANTIBODIES; IRRADIATION; MICROORGANISMS; OPTICAL COLLIMATORS; OPTICAL RESOLVING POWER; PHOSPHORS; PHOTOMULTIPLIERS; SCINTILLATION COUNTERS; SENSITIVITY ANALYSIS; SIGNAL TO NOISE RATIO;

EID: 23844496429     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2005.851428     Document Type: Article
Times cited : (24)

References (9)
  • 1
    • 0035284484 scopus 로고    scopus 로고
    • High resolution PET, SPECT and projection imaging in small animals
    • M. V. Green et al., "High resolution PET, SPECT and projection imaging in small animals," Comput. Med. Imaging Graph., vol. 25, pp. 79-86, 2001.
    • (2001) Comput. Med. Imaging Graph. , vol.25 , pp. 79-86
    • Green, M.V.1
  • 2
    • 0036815779 scopus 로고    scopus 로고
    • Evaluation of A-SPECT: A desktop pinhole SPECT system for small animal imaging
    • Oct.
    • B. Tsui et al., "Evaluation of A-SPECT: A desktop pinhole SPECT system for small animal imaging," IEEE Trans. Nucl. Sci., vol. 49, no. 5, pp. 2139-2147, Oct. 2002.
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , Issue.5 , pp. 2139-2147
    • Tsui, B.1
  • 3
    • 0035555132 scopus 로고    scopus 로고
    • Design of high sensitivity, high resolution, compact single photon imaging devices for small animal and dedicated breast imaging
    • M. Smith et al., "Design of high sensitivity, high resolution, compact single photon imaging devices for small animal and dedicated breast imaging," presented at the IEEE 2001 Medical Imaging Conf. (MIC).
    • IEEE 2001 Medical Imaging Conf. (MIC)
    • Smith, M.1
  • 4
    • 0035555114 scopus 로고    scopus 로고
    • Development of a multipinhole detector for high sensitivity SPECT imaging
    • N. Schramm et al., "Development of a multipinhole detector for high sensitivity SPECT imaging," presented at the IEEE 2001 Medical Imaging Conf. (MIC).
    • IEEE 2001 Medical Imaging Conf. (MIC)
    • Schramm, N.1
  • 5
    • 0037457857 scopus 로고    scopus 로고
    • Scintillator and photodetector array optimization for functional breast imaging
    • F. Garibaldi et al., "Scintillator and photodetector array optimization for functional breast imaging," NIM A, vol. 497, pp. 51-59, 2003.
    • (2003) NIM A , vol.497 , pp. 51-59
    • Garibaldi, F.1
  • 7
    • 0019570779 scopus 로고
    • Uniformly redundant arrays: Digital reconstruction methods
    • E. E. Fenimore and T. Cannon, "Uniformly redundant arrays: Digital reconstruction methods," Appl. Opt., vol. 20, no. 10, pp. 1858-1864, 1981.
    • (1981) Appl. Opt. , vol.20 , Issue.10 , pp. 1858-1864
    • Fenimore, E.E.1    Cannon, T.2
  • 8
    • 84975577929 scopus 로고
    • New family of binary arrays for coded aperture imaging
    • S. R. Gottesman and E. E. Fenimore, "New family of binary arrays for coded aperture imaging," Appl. Opt., vol. 28, pp. 4344-4352, 1989.
    • (1989) Appl. Opt. , vol.28 , pp. 4344-4352
    • Gottesman, S.R.1    Fenimore, E.E.2
  • 9
    • 0035725801 scopus 로고    scopus 로고
    • A coded aperture for high resolution nuclear medicine planar imaging with a conventional Anger camera: Experimental results
    • Dec.
    • R. Accorsi, F. Gasparini, and R. C. Lanza, "A coded aperture for high resolution nuclear medicine planar imaging with a conventional Anger camera: Experimental results," IEEE Trans. Nucl. Sci., vol. 48, no. 6, pp. 2411-2417, Dec. 2001.
    • (2001) IEEE Trans. Nucl. Sci. , vol.48 , Issue.6 , pp. 2411-2417
    • Accorsi, R.1    Gasparini, F.2    Lanza, R.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.