Volumn 5, Issue , 2004, Pages 3084-3088

A delta-scatter Monte Carlo model of a rotating parallel-hole collimator for131i brain tumor imaging

Author keywords

[No Author keywords available]

Indexed keywords

BRAIN; CAMERAS; MATHEMATICAL MODELS; MEDICAL IMAGING; OPTICAL COLLIMATORS; PHOTONS; TUMORS; VISUALIZATION;

EID: 23844486409     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (2)

References (8)
  • 1
    • 0032140486 scopus 로고    scopus 로고
    • A rotating parallel-hole collimator for high resolution imaging of medium energy radionuclides
    • M. F. Smith and R. J. Jaszozak, "A Rotating Parallel-Hole Collimator for High Resolution Imaging of Medium Energy Radionuclides," IEEE Trans. Nucl. Sci. vol. 45, pp. 2102-2112, 1998
    • (1998) IEEE Trans. Nucl. Sci. , vol.45 , pp. 2102-2112
    • Smith, M.F.1    Jaszozak, R.J.2
  • 2
    • 0036624601 scopus 로고    scopus 로고
    • Combination of MCNP and simSET for Monte Carlo simulation of SPECT for medium- And high-energy photons
    • Y. Du, C. Frey, W.T. Want, C. Tocharoenchai, W. H. Baird, and B. M. W. Tsui, "Combination of MCNP and SimSET for Monte Carlo Simulation of SPECT for Medium- and High-Energy Photons," IEEE Trans. Nucl. Sci. vol. 49, pp. 668-679, 2002
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , pp. 668-679
    • Du, Y.1    Frey, C.2    Want, W.T.3    Tocharoenchai, C.4    Baird, W.H.5    Tsui, B.M.W.6
  • 4
    • 0001780703 scopus 로고
    • Mathematical verification of a certain Monte Carlo sampling technique and the application of the technique to radiation transport problems
    • W. A. Coleman, "Mathematical verification of a certain Monte Carlo sampling technique and the application of the technique to radiation transport problems," Nucl. Sci. Eng. Vol. 32, 1968 pp. 76-81
    • (1968) Nucl. Sci. Eng. , vol.32 , pp. 76-81
    • Coleman, W.A.1
  • 5
    • 0006477735 scopus 로고
    • Monte Carlo in diagnostic radiology
    • R. L. Morin, Ed., Boca Raton: CRC Press, Inc.
    • H-P . Chan and K. Doi, "Monte Carlo in Diagnostic Radiology," in Monte Carlo Simulation in the Radiological Sciences, R. L. Morin, Ed., Boca Raton: CRC Press, Inc., 1988 pp. 163-166
    • (1988) Monte Carlo Simulation in the Radiological Sciences , pp. 163-166
    • Chan, H.-P.1    Doi, K.2
  • 8
    • 0032312976 scopus 로고    scopus 로고
    • 131i SPECT with triple energy window compton scatter correction
    • 131I SPECT with Triple Energy Window Compton Scatter Correction," IEEE Trans. Nucl. Sci. 45 pp. 3109-3144 1998
    • (1998) IEEE Trans. Nucl. Sci. , vol.45 , pp. 3109-3144
    • Dewaraja, Y.1    Li, J.2    Koral, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.