Volumn 3, Issue , 2004, Pages 1649-1653

Development and performances of a dental digital radiographic system using a high resolution CCD image sensor

Author keywords

[No Author keywords available]

Indexed keywords

CHARGE COUPLED DEVICES; DIGITAL IMAGE STORAGE; IMAGE QUALITY; IMAGE RETRIEVAL; OPTICAL TRANSFER FUNCTION; RADIOGRAPHY; X RAYS;

EID: 23844463519     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (5)

References (10)
  • 1
    • 33645266606 scopus 로고    scopus 로고
    • Development and evaluation of a CMOS sensor based digital intra-oral radiographic system
    • submitted for publication
    • S. Hong, H. Jung, K-D. Kim, S-G. So, J-H. Kim, S. K. Yoo, H. S. Yoo, H-J. Kim, "Development and Evaluation of a CMOS Sensor Based Digital Intra-oral Radiographic System," IEEE TNS, submitted for publication.
    • IEEE TNS
    • Hong, S.1    Jung, H.2    Kim, K.-D.3    So, S.-G.4    Kim, J.-H.5    Yoo, S.K.6    Yoo, H.S.7    Kim, H.-J.8
  • 6
    • 33645268198 scopus 로고    scopus 로고
    • Computed microtomography (μCT) with unmonochromatized synchrotron X-rays for cancerous human breast tissue and mouse vertebra
    • H. Jung, H. J. Kim, S. Hong, J. O. Hong, H. K. Jeong, H. J. Jung, B. R. Kim, H. S. Yoo, "Computed Microtomography (μCT) with Unmonochromatized Synchrotron X-rays for Cancerous Human Breast Tissue and Mouse Vertebra," IEEE TNS, vol. 49, pp. 5-10, 2002.
    • (2002) IEEE TNS , vol.49 , pp. 5-10
    • Jung, H.1    Kim, H.J.2    Hong, S.3    Hong, J.O.4    Jeong, H.K.5    Jung, H.J.6    Kim, B.R.7    Yoo, H.S.8
  • 7
    • 0031950889 scopus 로고    scopus 로고
    • A method for measuring the presampled MTF of digital radiographic systems using an edge test device
    • E. Samei, M. J. Flynn, D. A. Reimann, "A method for measuring the presampled MTF of digital radiographic systems using an edge test device," Med. Phys. vol. 25(1), pp. 102-13, 1998.
    • (1998) Med. Phys. , vol.25 , Issue.1 , pp. 102-113
    • Samei, E.1    Flynn, M.J.2    Reimann, D.A.3
  • 8
    • 0032706138 scopus 로고    scopus 로고
    • A synchrotron radiation microtomography system for the analysis of trabecular bone samples
    • M. Salome, F. Peyrin, P. Cloetens, C. Odet, AM. Laval-Jeantet, J. Baruchel, P. Spanne, "A synchrotron radiation microtomography system for the analysis of trabecular bone samples," Med. Phys. vol. 26(10), pp. 2194-204, 1999.
    • (1999) Med. Phys. , vol.26 , Issue.10 , pp. 2194-2204
    • Salome, M.1    Peyrin, F.2    Cloetens, P.3    Odet, C.4    Laval-Jeantet, A.M.5    Baruchel, J.6    Spanne, P.7
  • 9
    • 0034516219 scopus 로고    scopus 로고
    • Image quality evaluation of a desktop computer radiography system
    • A. Kenneth, J. Fetterly and Nicholas, Hangiandreou, "Image quality evaluation of a desktop computer radiography system." Med. Phys, vol. 27(12), pp. 2669-79, 2000.
    • (2000) Med. Phys , vol.27 , Issue.12 , pp. 2669-2679
    • Kenneth, A.1    Fetterly, J.2    Nicholas, H.3