메뉴 건너뛰기




Volumn 4, Issue , 2004, Pages 2461-2464

Toward a medipix2 coded aperture gamma microscope

Author keywords

[No Author keywords available]

Indexed keywords

AMPLIFIERS (ELECTRONIC); GAMMA RAYS; IMAGE RECONSTRUCTION; MEDICAL IMAGING; OPTICAL CORRELATION; RADIOISOTOPES; SIGNAL TO NOISE RATIO; SPURIOUS SIGNAL NOISE;

EID: 23844463243     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (12)

References (12)
  • 1
    • 10744225618 scopus 로고    scopus 로고
    • Preliminary tests of a prototype system for optical and radionuclide imaging in small animals
    • L. Celentano et al., "Preliminary Tests of a Prototype System for Optical and Radionuclide Imaging in Small Animals," IEEE Trans. Nucl. Sci, vol. 50, pp. 1693-1701, 2003.
    • (2003) IEEE Trans. Nucl. Sci , vol.50 , pp. 1693-1701
    • Celentano, L.1
  • 2
    • 33645209433 scopus 로고    scopus 로고
    • Experimental study on in vivo optical and radionuclide imaging in small animals
    • in press
    • M. Autiero et al., "Experimental Study on In Vivo Optical and Radionuclide Imaging in Small Animals," IEEE Trans. Nucl. Sci., 2004 (in press).
    • (2004) IEEE Trans. Nucl. Sci.
    • Autiero, M.1
  • 6
    • 48749135174 scopus 로고
    • Imaging with coded aperture masks
    • G. K. Skinner, "Imaging with coded aperture masks," Nucl. Instrum. Meth A., vol. 221, pp. 33-40, 1984.
    • (1984) Nucl. Instrum. Meth A. , vol.221 , pp. 33-40
    • Skinner, G.K.1
  • 7
    • 0017935435 scopus 로고
    • Coded aperture imaging with uniformly redundant arrays
    • E. E. Fenimore and T. M. Cannon, "Coded aperture imaging with uniformly redundant arrays,"Appl. Opt., vol. 17, pp. 337-347, 1978.
    • (1978) Appl. Opt. , vol.17 , pp. 337-347
    • Fenimore, E.E.1    Cannon, T.M.2
  • 8
    • 0018035137 scopus 로고
    • Coded aperture imaging: Predicted performance of uniformly redundant arrays
    • E. E. Fenimore, "Coded aperture imaging: predicted performance of uniformly redundant arrays,"Appl. Opt., vol. 17, pp. 3562-3570, 1978.
    • (1978) Appl. Opt. , vol.17 , pp. 3562-3570
    • Fenimore, E.E.1
  • 9
    • 84975577929 scopus 로고
    • New family of binary arrays for coded aperture imaging
    • S. R. Gottesman and E. E. Fenimore, "New family of binary arrays for coded aperture imaging," Appl. Opt., vol. 28, pp. 4344-4352, 1989.
    • (1989) Appl. Opt. , vol.28 , pp. 4344-4352
    • Gottesman, S.R.1    Fenimore, E.E.2
  • 10
    • 0019570779 scopus 로고
    • Uniformly redundant arrays: Digital reconstruction methods
    • E. E. Fenimore and T. M. Cannon, "Uniformly redundant arrays: digital reconstruction methods," Appl. Opt., vol. 20, no. 10, pp. 1858-1864, 1981.
    • (1981) Appl. Opt. , vol.20 , Issue.10 , pp. 1858-1864
    • Fenimore, E.E.1    Cannon, T.M.2
  • 11
    • 0001341373 scopus 로고    scopus 로고
    • Near-field artifact reduction in Coded Aperture Imaging
    • R. Accorsi and R. C. Lanza, "Near-field artifact reduction in Coded Aperture Imaging,"Appl. Opt., vol. 40, pp. 4697-4705, 2001.
    • (2001) Appl. Opt. , vol.40 , pp. 4697-4705
    • Accorsi, R.1    Lanza, R.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.