메뉴 건너뛰기




Volumn 5748, Issue , 2005, Pages 244-255

An assessment of the performance and quality control procedures of PACS workstation monitors used in irish radiology departments

Author keywords

AAPM TG18; CRT; SMPTE; Workstation monitor

Indexed keywords

CALIBRATION; COMPUTER MONITORS; COMPUTER WORKSTATIONS; IMAGE QUALITY; IMAGING TECHNIQUES; MEDICAL IMAGING; QUALITY CONTROL; RADIOGRAPHY;

EID: 23844440705     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.593954     Document Type: Conference Paper
Times cited : (6)

References (11)
  • 1
    • 0029246379 scopus 로고
    • Quality control of cathode ray tube monitors for medical imaging using a simple photometer
    • Parsons DM, Kim Y & Haynor DR (1995). Quality control of cathode ray tube monitors for medical imaging using a simple photometer. Journal of Digital Imaging, 8, (1): 10-20.
    • (1995) Journal of Digital Imaging , vol.8 , Issue.1 , pp. 10-20
    • Parsons, D.M.1    Kim, Y.2    Haynor, D.R.3
  • 2
    • 0000332877 scopus 로고    scopus 로고
    • The monochrome cathode ray tube display and its performance
    • Kim Y & Horii SC, Eds. Bellingham WA: SPIE press
    • Roehrig H (2000). The monochrome cathode ray tube display and its performance. In: Kim Y & Horii SC, Eds. Handbook of medical imaging. Vol. 3 Bellingham WA: SPIE press, pp 156-220.
    • (2000) Handbook of Medical Imaging , vol.3 , pp. 156-220
    • Roehrig, H.1
  • 3
    • 79551716487 scopus 로고    scopus 로고
    • Assessment of display performance for medical imaging systems
    • Publication
    • AAPM, Assessment of display performance for medical imaging systems, Report of the AAPM Task Group No. 18, Publication, 2002.
    • (2002) Report of the AAPM Task Group No. 18
  • 4
    • 0037307004 scopus 로고    scopus 로고
    • Viewing Conditions for Diagnostic images in three major Dublin hospitals: A comparison with WHO and CEC recommendations
    • McCarthy E & Brennan PC (2003). Viewing Conditions for Diagnostic images in three major Dublin hospitals: a comparison with WHO and CEC recommendations. British Journal of Radiology, 76:1-4.
    • (2003) British Journal of Radiology , vol.76 , pp. 1-4
    • McCarthy, E.1    Brennan, P.C.2
  • 5
    • 85040300521 scopus 로고
    • Geneva, Switzerland: World Health Organisation, 1982
    • WHO (1982). Quality assurance in diagnostic radiology. Geneva, Switzerland: World Health Organisation, 1982.
    • (1982) Quality Assurance in Diagnostic Radiology
  • 6
    • 33645198684 scopus 로고    scopus 로고
    • American College of Radiology, 1891 Preston White Drive, Reston, VA 20191-4397, USA. [online]
    • American College of Radiology, ACR Standard for Teleradiology, (1999). American College of Radiology, 1891 Preston White Drive, Reston, VA 20191-4397, USA. [online]. Available from: http//:www.acr.org
    • (1999)
  • 7
    • 0033625304 scopus 로고    scopus 로고
    • Contrast-detail characteristic evaluations of several display devices
    • Wang J, Lane T, Stetson C & Moore J (2000). Contrast-detail characteristic evaluations of several display devices. Journal of Digital Imaging, 13: 162-67.
    • (2000) Journal of Digital Imaging , vol.13 , pp. 162-167
    • Wang, J.1    Lane, T.2    Stetson, C.3    Moore, J.4
  • 8
    • 3042591064 scopus 로고    scopus 로고
    • Assessment of monitor conditions for the display of radiological diagnostic images and ambient lighting
    • Wade C & Brennan PC (2003). Assessment of monitor conditions for the display of radiological diagnostic images and ambient lighting. British Journal of Radiology, 77: 1-7.
    • (2003) British Journal of Radiology , vol.77 , pp. 1-7
    • Wade, C.1    Brennan, P.C.2
  • 10
    • 0033277470 scopus 로고    scopus 로고
    • Influence of film and monitor display luminance on observer performance and visual search
    • Krupinski E, Roehrig H & Furuwaka T (1999). Influence of film and monitor display luminance on observer performance and visual search. Academic Radiology, 6:411-418.
    • (1999) Academic Radiology , vol.6 , pp. 411-418
    • Krupinski, E.1    Roehrig, H.2    Furuwaka, T.3
  • 11
    • 0035345373 scopus 로고    scopus 로고
    • Cathode ray tube quality control and acceptance testing program: Initial results for clinical PACS displays
    • Groth D, Bernatz S, Fetterly K & Hangiandreou NJ (2001). Cathode ray tube quality control and acceptance testing program: Initial results for clinical PACS displays. Radiographics, 21: 719-732.
    • (2001) Radiographics , vol.21 , pp. 719-732
    • Groth, D.1    Bernatz, S.2    Fetterly, K.3    Hangiandreou, N.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.