메뉴 건너뛰기




Volumn 235, Issue 17-19, 2005, Pages 1777-1788

Application of the Seebeck effect for monitoring of neutron embrittlement and low-cycle fatigue in nuclear reactor steel

Author keywords

[No Author keywords available]

Indexed keywords

DEGRADATION; EMBRITTLEMENT; FATIGUE OF MATERIALS; PRESSURE VESSELS; SEEBECK EFFECT; STEEL; THERMOELECTRICITY;

EID: 23744462349     PISSN: 00295493     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.nucengdes.2005.05.026     Document Type: Article
Times cited : (17)

References (12)
  • 2
    • 84946035092 scopus 로고    scopus 로고
    • Assessment of Steels Ageing by Measuring the Seebeck and Thomson Effects (STEAM)
    • Rome, October 15-21
    • L. Debarberis, and B. Acosta Assessment of Steels Ageing by Measuring the Seebeck and Thomson Effects (STEAM) 15th World Conference on Non-Destructive Testing Rome, October 15-21 2000
    • (2000) 15th World Conference on Non-Destructive Testing
    • Debarberis, L.1    Acosta, B.2
  • 3
    • 0018982226 scopus 로고
    • How do thermocouples work?
    • A.W. Fenton How do thermocouples work? Nucl. Eng. 19 February (1) 1980 61 63
    • (1980) Nucl. Eng. , vol.19 , Issue.1 , pp. 61-63
    • Fenton, A.W.1
  • 4
    • 0035396339 scopus 로고    scopus 로고
    • Monitoring of low-cycle fatigue degradation in X6CrNiTi18-10 austenitic steel
    • M. Grosse, M. Niffenegger, and D. Kalkhof Monitoring of low-cycle fatigue degradation in X6CrNiTi18-10 austenitic steel J. Nucl. Mater. 296 2001 305 311
    • (2001) J. Nucl. Mater. , vol.296 , pp. 305-311
    • Grosse, M.1    Niffenegger, M.2    Kalkhof, D.3
  • 7
    • 0016035516 scopus 로고
    • How accurate are thermocouples, anyway? Age and impurities change them: How much is the question
    • D.R. Keyser How accurate are thermocouples, anyway? Age and impurities change them: how much is the question Instrum. Control Syst. 47 3 1974 51 54
    • (1974) Instrum. Control Syst. , vol.47 , Issue.3 , pp. 51-54
    • Keyser, D.R.1
  • 9
    • 0016573870 scopus 로고
    • Temperature measurement errors with type K thermocouples due to short-range ordering in Chromel
    • T.G. Kollie Temperature measurement errors with type K thermocouples due to short-range ordering in Chromel Rev. Scl. Instrum. 46 11 1975
    • (1975) Rev. Scl. Instrum. , vol.46 , Issue.11
    • Kollie, T.G.1
  • 10
    • 33644574237 scopus 로고
    • The Stability of microthermocouples in the 400-1200 °c temperature range
    • V.A. Krivtsov The Stability of microthermocouples in the 400-1200 °C temperature range Teploenergetika 20 10 1973 76
    • (1973) Teploenergetika , vol.20 , Issue.10 , pp. 76
    • Krivtsov, V.A.1
  • 11
    • 33644580927 scopus 로고    scopus 로고
    • The change of the seebeck coefficient due to neutron irradiation and thermal fatigue of nuclear reactor, pressure vessel steel and its application to the monitoring of material degradation
    • ISSN 1019-0643
    • Niffenegger, M., Reichlin, K., Kalkhof, D., 2002. The Change of the Seebeck Coefficient due to Neutron Irradiation and Thermal Fatigue of Nuclear Reactor, Pressure Vessel Steel and its Application to the Monitoring of Material Degradation, PSI Report No. 02-11, ISSN 1019-0643.
    • (2002) PSI Report No. 02-11 , vol.2 , Issue.11
    • Niffenegger, M.1    Reichlin, K.2    Kalkhof, D.3
  • 12
    • 0015961213 scopus 로고
    • Accuracy of Type K thermocouple wire below 500 K: A statistical analysis
    • D.G. Sanders Accuracy of Type K thermocouple wire below 500 K: a statistical analysis ISA Trans. 13 1974 200 211
    • (1974) ISA Trans. , vol.13 , pp. 200-211
    • Sanders, D.G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.