메뉴 건너뛰기




Volumn 38, Issue 10, 2005, Pages 2058-2069

Blood velocity field numerical assessment using a GPL code in case of intravascular Doppler catheter affections: Comparative analysis of different rheological models

Author keywords

Blood flow; Intravascular Doppler catheter; Numerical codes; Tochnog

Indexed keywords

BLOOD; CARDIOLOGY; FINITE ELEMENT METHOD; MATHEMATICAL MODELS; RHEOLOGY; VELOCITY MEASUREMENT;

EID: 23444451284     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2004.09.002     Document Type: Article
Times cited : (11)

References (21)
  • 2
    • 0036804468 scopus 로고    scopus 로고
    • Blood flow patterns in an anatomically realistic coronary vessel: Influence of three different reconstruction methods
    • B. Berthier, R. Bouzerar, and C. Legallais Blood flow patterns in an anatomically realistic coronary vessel influence of three different reconstruction methods Journal of Biomechanics 35 2002 1347 1356
    • (2002) Journal of Biomechanics , vol.35 , pp. 1347-1356
    • Berthier, B.1    Bouzerar, R.2    Legallais, C.3
  • 3
    • 0001899137 scopus 로고
    • A flow equation for pigment-oil suspensions of printing ink type
    • C.C. Mills Pergamon Press London
    • N.A. Casson A flow equation for pigment-oil suspensions of printing ink type C.C. Mills Rheology of Disperse Systems 1959 Pergamon Press London 84 102
    • (1959) Rheology of Disperse Systems , pp. 84-102
    • Casson, N.A.1
  • 4
    • 0030152411 scopus 로고    scopus 로고
    • Power Doppler ultrasound evaluation of the shear rate and shear stress dependences of red blood cell aggregation
    • G. Cloutier, Z. Qin, and L.-G. Durand Power Doppler ultrasound evaluation of the shear rate and shear stress dependences of red blood cell aggregation IEEE Transactions on Biomedical Engineering 43 5 1996 441 450
    • (1996) IEEE Transactions on Biomedical Engineering , vol.43 , Issue.5 , pp. 441-450
    • Cloutier, G.1    Qin, Z.2    Durand, L.-G.3
  • 5
    • 0030199797 scopus 로고    scopus 로고
    • Estimation of increased flow resistance in a narrow catheterized artery - A theoretical model
    • R.K. Dash, G. Jayaraman, and K.N. Mehta Estimation of increased flow resistance in a narrow catheterized artery - a theoretical model Journal of Biomechanics 29 7 1996 917 930
    • (1996) Journal of Biomechanics , vol.29 , Issue.7 , pp. 917-930
    • Dash, R.K.1    Jayaraman, G.2    Mehta, K.N.3
  • 7
    • 0032991356 scopus 로고    scopus 로고
    • The influence of the non-Newtonian properties of blood on the flow in large arteries: Unsteady flow in a 90° curved tube
    • F.J.H. Gijsen, E. Allanic, and F.N. van de Vosse The influence of the non-Newtonian properties of blood on the flow in large arteries unsteady flow in a 90° curved tube Journal of Biomechanics 32 1999 705 713
    • (1999) Journal of Biomechanics , vol.32 , pp. 705-713
    • Gijsen, F.J.H.1    Allanic, E.2    Van De Vosse, F.N.3
  • 8
    • 0032077677 scopus 로고    scopus 로고
    • Effect of non-Newtonian property of blood on flow through a stenosed tube
    • T. Ishikawa, L.F.R. Guimaraes, and S. Oshima Effect of non-Newtonian property of blood on flow through a stenosed tube Fluid Dynamics Research 22 1998 251 264
    • (1998) Fluid Dynamics Research , vol.22 , pp. 251-264
    • Ishikawa, T.1    Guimaraes, L.F.R.2    Oshima, S.3
  • 9
    • 0032828358 scopus 로고    scopus 로고
    • Measurement accuracy of the flow velocity in pulsed ultrasound doppler velocimeter
    • M. Kagiyama, Y. Ogasawara, and S. Tadaoka Measurement accuracy of the flow velocity in pulsed ultrasound doppler velocimeter Ultrasound in Medicine and Biology 25 8 1999 1265 1274
    • (1999) Ultrasound in Medicine and Biology , vol.25 , Issue.8 , pp. 1265-1274
    • Kagiyama, M.1    Ogasawara, Y.2    Tadaoka, S.3
  • 11
    • 0032320810 scopus 로고    scopus 로고
    • A numerical study of the flow disturbance caused by an intravascular Doppler catheter in a blood vessel
    • Witpress
    • Lorenzini, G., 1998. A numerical study of the flow disturbance caused by an intravascular Doppler catheter in a blood vessel. Advances in Fluid Mechanics II, Witpress, pp. 103-112.
    • (1998) Advances in Fluid Mechanics II , pp. 103-112
    • Lorenzini, G.1
  • 13
    • 4644310652 scopus 로고    scopus 로고
    • Finite element modelling applied to velocity field in region of an intravascular Doppler catheter: Study for symmetric annulus
    • G. Lorenzini, O. Saro, and M.W. Collins Finite element modelling applied to velocity field in region of an intravascular Doppler catheter study for symmetric annulus Internal Medicine 7 1999 25 31
    • (1999) Internal Medicine , vol.7 , pp. 25-31
    • Lorenzini, G.1    Saro, O.2    Collins, M.W.3
  • 14
    • 0026910231 scopus 로고
    • Study on the constitutive equation of blood
    • X.Y. Luo, and Z.B. Kuang Study on the constitutive equation of blood Journal of Biomechanics 25 8 1992 929 934
    • (1992) Journal of Biomechanics , vol.25 , Issue.8 , pp. 929-934
    • Luo, X.Y.1    Kuang, Z.B.2
  • 15
    • 0019445231 scopus 로고
    • A rheological model for studying the hematocrit dependence red cell-red cell and cell-protein interaction in blood
    • D. Quemada A rheological model for studying the hematocrit dependence red cell-red cell and cell-protein interaction in blood Biorheology 18 1981 501 514
    • (1981) Biorheology , vol.18 , pp. 501-514
    • Quemada, D.1
  • 16
    • 0036122893 scopus 로고    scopus 로고
    • Measurement of blood viscosity using mass-detecting sensor
    • S. Shin, and D.-Y. Keum Measurement of blood viscosity using mass-detecting sensor Biosensors and Bioelectronics 17 5 2000 383 388
    • (2000) Biosensors and Bioelectronics , vol.17 , Issue.5 , pp. 383-388
    • Shin, S.1    Keum, D.-Y.2
  • 17
    • 0023009870 scopus 로고
    • Subselective measurement of coronary blood flow velocity using a steerable Doppler catheter
    • D.H. Sibley, H.D. Millar, and C.J. Hartley Subselective measurement of coronary blood flow velocity using a steerable Doppler catheter Journal of the American College of Cardiology 8 1986 1332 1340
    • (1986) Journal of the American College of Cardiology , vol.8 , pp. 1332-1340
    • Sibley, D.H.1    Millar, H.D.2    Hartley, C.J.3
  • 18
    • 0017118576 scopus 로고
    • A constitutive equation for whole human blood
    • F.J. Walburn, and D.J. Schneck A constitutive equation for whole human blood Biorheology 13 1976 201 218
    • (1976) Biorheology , vol.13 , pp. 201-218
    • Walburn, F.J.1    Schneck, D.J.2
  • 19
    • 0021844959 scopus 로고    scopus 로고
    • Transluminal, subselective measurement of coronary artery blood flow velocity and vasodilator reserve in man
    • R.F. Wilson, D.E. Laughlin, P.H. Ackell, and W.M. Chilian Transluminal, subselective measurement of coronary artery blood flow velocity and vasodilator reserve in man Circulation 72 2003 82 92
    • (2003) Circulation , vol.72 , pp. 82-92
    • Wilson, R.F.1    Laughlin, D.E.2    Ackell, P.H.3    Chilian, W.M.4
  • 20
    • 0025844826 scopus 로고
    • Validity of catheter-tip Doppler techniques in assessment of coronary flow velocity and application of spectrum analysis method
    • M. Yamagishi, D. Hotta, and J. Tamai Validity of catheter-tip Doppler techniques in assessment of coronary flow velocity and application of spectrum analysis method American Journal of Cardiology 67 1991 758 762
    • (1991) American Journal of Cardiology , vol.67 , pp. 758-762
    • Yamagishi, M.1    Hotta, D.2    Tamai, J.3
  • 21
    • 0033622807 scopus 로고    scopus 로고
    • Study on blood constitutive parameters in different blood constitutive equations
    • J.-B. Zhang, and Z.-B. Kuang Study on blood constitutive parameters in different blood constitutive equations Journal of Biomechanics 33 2000 355 360
    • (2000) Journal of Biomechanics , vol.33 , pp. 355-360
    • Zhang, J.-B.1    Kuang, Z.-B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.