메뉴 건너뛰기




Volumn 24, Issue 3, 2005, Pages

The finite element analysis of the transitorily expanding process and design optimization of coronary stent system

Author keywords

Design optimization; FEA FEM; Restenosis; Stent

Indexed keywords

BLOOD VESSELS; CARDIOLOGY; COMPUTER SIMULATION; DISEASES; FINITE ELEMENT METHOD; OPTIMIZATION;

EID: 23444440858     PISSN: 02588021     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (2)

References (9)
  • 2
    • 0036315739 scopus 로고    scopus 로고
    • Coronary artery stents: Evaluating new designs for contemporary percutaneous intervention
    • Kandzari DE, Tcheng JE, Zidar JP. Coronary artery stents: evaluating new designs for contemporary percutaneous intervention[J]. Cathet Cardiovasc Intervent, 2002, 56: 562-576.
    • (2002) Cathet Cardiovasc Intervent , vol.56 , pp. 562-576
    • Kandzari, D.E.1    Tcheng, J.E.2    Zidar, J.P.3
  • 3
    • 0029004856 scopus 로고
    • Endovascular stent design dictates experimental restenosis and thrombosis
    • Rogers C, Edelman ER, Elazer R. Edelman. Endovascular stent design dictates experimental restenosis and thrombosis[J]. Circulation, 1995, 91: 2995-3001.
    • (1995) Circulation , vol.91 , pp. 2995-3001
    • Rogers, C.1    Edelman, E.R.2    Edelman, E.R.3
  • 4
    • 0034067045 scopus 로고    scopus 로고
    • Coronary stent symmetry and vascular injury determine experimental restenosis
    • Schulz C, Herrmann R A, Beihzrz C, et al. Coronary stent symmetry and vascular injury determine experimental restenosis[J]. Heart, 2000, 83: 462-467.
    • (2000) Heart , vol.83 , pp. 462-467
    • Schulz, C.1    Herrmann, R.A.2    Beihzrz, C.3
  • 5
    • 0033525544 scopus 로고    scopus 로고
    • Ballon-artery interactions during stent placement: A finite element analysis approach to pressure, compliance, and stent design as contributors to vascular injury
    • Rogers C, Tseng DY, Squire JC, et al. Ballon-artery interactions during stent placement: a finite element analysis approach to pressure, compliance, and stent design as contributors to vascular injury[J]. Circ Res, 1999, 84: 378-383.
    • (1999) Circ Res , vol.84 , pp. 378-383
    • Rogers, C.1    Tseng, D.Y.2    Squire, J.C.3
  • 6
    • 0033851947 scopus 로고    scopus 로고
    • Experimental evaluation of a short transitional edge protection balloon for intracoronary stent deployment
    • Carter AJ, Lee DP, Suzuki T, et al. Experimental evaluation of a short transitional edge protection balloon for intracoronary stent deployment[J]. Cathet Cardiovasc Intervent, 2005, 51: 112-119.
    • (2005) Cathet Cardiovasc Intervent , vol.51 , pp. 112-119
    • Carter, A.J.1    Lee, D.P.2    Suzuki, T.3
  • 7
    • 18344376936 scopus 로고    scopus 로고
    • Ph. D. Thesis, Massachusetts Institute of Technology Press, MA, USA
    • Squire JC. Dynamics of endovascular stent expansion[D]. Ph. D. Thesis, Massachusetts Institute of Technology Press, MA, USA, 2000, 41-89.
    • (2000) Dynamics of Endovascular Stent Expansion[D] , pp. 41-89
    • Squire, J.C.1
  • 8
    • 0036000226 scopus 로고    scopus 로고
    • Mechanical behaviour of coronary stents investigated through the finite element method
    • Migliavacca F, Petrini L, Colombo M, et al. Mechanical behaviour of coronary stents investigated through the finite element method[J]. Journal of Biomechanics, 2002, 35: 803-811.
    • (2002) Journal of Biomechanics , vol.35 , pp. 803-811
    • Migliavacca, F.1    Petrini, L.2    Colombo, M.3
  • 9
    • 0029013213 scopus 로고
    • Luminal loss and site of restenosis after Palmaz-Schatz coronary stent implantation
    • Ikari Y, Hara K, Tamura T, et al. Luminal loss and site of restenosis after Palmaz-Schatz coronary stent implantation[J]. Am J Cardiol, 1995, 76: 117-120.
    • (1995) Am J Cardiol , vol.76 , pp. 117-120
    • Ikari, Y.1    Hara, K.2    Tamura, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.