-
1
-
-
0022708543
-
Design and performance of a modified buckle transducer for the measurement of ligament tension
-
D. Barry, and A.M. Ahmed Design and performance of a modified buckle transducer for the measurement of ligament tension Journal of Biomechanical Engineering 108 1986 149 152
-
(1986)
Journal of Biomechanical Engineering
, vol.108
, pp. 149-152
-
-
Barry, D.1
Ahmed, A.M.2
-
2
-
-
0036301829
-
Effect of bone cortical thickness on velocity measurements using ultrasonic axial transmission: A 2D simulation study
-
E. Bossy, M. Talmant, and P. Laugier Effect of bone cortical thickness on velocity measurements using ultrasonic axial transmission a 2D simulation study Journal of the Acoustical Society of America 112 2002 297 307
-
(2002)
Journal of the Acoustical Society of America
, vol.112
, pp. 297-307
-
-
Bossy, E.1
Talmant, M.2
Laugier, P.3
-
3
-
-
0022591312
-
Dynamic performance characteristics of the liquid metal strain gauge
-
T.D. Brown, L. Sigal, G.O. Njus, N.M. Njus, R.J. Singerman, and R.A. Brand Dynamic performance characteristics of the liquid metal strain gauge Journal of Biomechanics 19 1986 165 173
-
(1986)
Journal of Biomechanics
, vol.19
, pp. 165-173
-
-
Brown, T.D.1
Sigal, L.2
Njus, G.O.3
Njus, N.M.4
Singerman, R.J.5
Brand, R.A.6
-
5
-
-
0030207153
-
Segmental variations of in vitro mechanical properties in equine superficial digital flexor tendons
-
N. Crevier, P. Pourcelot, J.M. Denoix, D. Geiger, C. Bortolussi, X. Ribot, and M. Sanaa Segmental variations of in vitro mechanical properties in equine superficial digital flexor tendons American Journal of Veterinary Research 57 1996 1111 1117
-
(1996)
American Journal of Veterinary Research
, vol.57
, pp. 1111-1117
-
-
Crevier, N.1
Pourcelot, P.2
Denoix, J.M.3
Geiger, D.4
Bortolussi, C.5
Ribot, X.6
Sanaa, M.7
-
6
-
-
0036000235
-
Influence of loading rate and cable migration on fiberoptic measurement of tendon force
-
A. Erdemir, S.J. Piazza, and N.A. Sharkey Influence of loading rate and cable migration on fiberoptic measurement of tendon force Journal of Biomechanics 35 2002 857 862
-
(2002)
Journal of Biomechanics
, vol.35
, pp. 857-862
-
-
Erdemir, A.1
Piazza, S.J.2
Sharkey, N.A.3
-
7
-
-
0031933178
-
Achilles tendon loading during walking: Application of a novel optic fiber technique
-
T. Finni, P.V. Komi, and J. Lukkariniemi Achilles tendon loading during walking application of a novel optic fiber technique Europeen Journal of Applied Physiology 83 1998 289 291
-
(1998)
Europeen Journal of Applied Physiology
, vol.83
, pp. 289-291
-
-
Finni, T.1
Komi, P.V.2
Lukkariniemi, J.3
-
8
-
-
0034534074
-
In vivo human triceps surae and quadriceps femoris muscle function in a squat jump and counter movement jump
-
T. Finni, P.V. Komi, and V. Lepola In vivo human triceps surae and quadriceps femoris muscle function in a squat jump and counter movement jump Europeen Journal of Applied Physiology 83 2000 416 426
-
(2000)
Europeen Journal of Applied Physiology
, vol.83
, pp. 416-426
-
-
Finni, T.1
Komi, P.V.2
Lepola, V.3
-
9
-
-
0034021223
-
Factors influencing the output of an implantable force transducer
-
B.C. Fleming, G.D. Peura, and B.D. Beynnon Factors influencing the output of an implantable force transducer Journal of Biomechanics 33 2000 889 893
-
(2000)
Journal of Biomechanics
, vol.33
, pp. 889-893
-
-
Fleming, B.C.1
Peura, G.D.2
Beynnon, B.D.3
-
10
-
-
0027506067
-
Comparison between the directly measured achilles tendon force and the tendon force calculated from the ankle joint moment during vertical jumps
-
S. Fukashiro, P.V. Komi, M. Järvinen, and M. Miyashita Comparison between the directly measured achilles tendon force and the tendon force calculated from the ankle joint moment during vertical jumps Clinical Biomechanics 8 1993 25 30
-
(1993)
Clinical Biomechanics
, vol.8
, pp. 25-30
-
-
Fukashiro, S.1
Komi, P.V.2
Järvinen, M.3
Miyashita, M.4
-
13
-
-
0025920047
-
A comparison of the triceps surae and residual muscle moments at the ankle during cycling
-
R.J. Gregor, P.V. Komi, R.C. Browning, and M. Järvinen A comparison of the triceps surae and residual muscle moments at the ankle during cycling Journal of Biomechanics 24 1991 287 297
-
(1991)
Journal of Biomechanics
, vol.24
, pp. 287-297
-
-
Gregor, R.J.1
Komi, P.V.2
Browning, R.C.3
Järvinen, M.4
-
14
-
-
0024564478
-
Buckle muscle tension transducer, what does it measure?
-
D.W. Hahs, and R.N. Stiles Buckle muscle tension transducer, what does it measure? Journal of Biomechanics 22 1989 165 166
-
(1989)
Journal of Biomechanics
, vol.22
, pp. 165-166
-
-
Hahs, D.W.1
Stiles, R.N.2
-
16
-
-
0028434083
-
In vivo forces in the anterior cruciate ligament: Direct measurements during walking and trotting in a quadruped
-
J.P. Holden, E.S. Grood, D.L. Korvick, J.F. Cummings, D.L. Butler, and D.I. Bylski-Austrow In vivo forces in the anterior cruciate ligament direct measurements during walking and trotting in a quadruped Journal of Biomechanics 27 1994 517 526
-
(1994)
Journal of Biomechanics
, vol.27
, pp. 517-526
-
-
Holden, J.P.1
Grood, E.S.2
Korvick, D.L.3
Cummings, J.F.4
Butler, D.L.5
Bylski-Austrow, D.I.6
-
17
-
-
0028958365
-
Cummings JF Factors affecting sensitivity of a transducer for measuring anterior cruciate ligament force
-
J.P. Holden, E.S. Grood, and D.L. Korvick Cummings JF Factors affecting sensitivity of a transducer for measuring anterior cruciate ligament force Journal of Biomechanics 28 1995 99 102
-
(1995)
Journal of Biomechanics
, vol.28
, pp. 99-102
-
-
Holden, J.P.1
Grood, E.S.2
Korvick, D.L.3
-
18
-
-
0025668479
-
Relevance of in vivo force measurements to human biomechanics
-
P.V. Komi Relevance of in vivo force measurements to human biomechanics Journal of Biomechanics 23 1990 23 24
-
(1990)
Journal of Biomechanics
, vol.23
, pp. 23-24
-
-
Komi, P.V.1
-
19
-
-
0026655518
-
Biomechanical loading of Achilles tendon during normal locomotion
-
P.V. Komi, S. Fukashiro, and M. JaÈrvinen Biomechanical loading of Achilles tendon during normal locomotion Clinics in Sports Medicine 11 1992 521 531
-
(1992)
Clinics in Sports Medicine
, vol.11
, pp. 521-531
-
-
Komi, P.V.1
Fukashiro, S.2
JaÈrvinen, M.3
-
21
-
-
0030047304
-
Optic fibre as a transducer of tendomuscular forces
-
P.V. Komi, A. Belli, V. Huttunen, R. Bonnefoy, A. Geyssant, and J.R. Lacour Optic fibre as a transducer of tendomuscular forces European Journal of Applied Physiology 72 1996 278 280
-
(1996)
European Journal of Applied Physiology
, vol.72
, pp. 278-280
-
-
Komi, P.V.1
Belli, A.2
Huttunen, V.3
Bonnefoy, R.4
Geyssant, A.5
Lacour, J.R.6
-
22
-
-
0020134577
-
A note on the application and evaluation of the buckle transducer for knee ligament force measurement
-
J.L. Lewis, W.D. Lew, and J. Schmidt A note on the application and evaluation of the buckle transducer for knee ligament force measurement Journal of Biomechanical Engineering 104 1982 125 128
-
(1982)
Journal of Biomechanical Engineering
, vol.104
, pp. 125-128
-
-
Lewis, J.L.1
Lew, W.D.2
Schmidt, J.3
-
23
-
-
0022155717
-
In vitro mechanical properties of equine tendons in relation to cross-sectional area and collagen content
-
D.J. Riemersma, and H.C. Schamhardt In vitro mechanical properties of equine tendons in relation to cross-sectional area and collagen content Research in Veterinary Science 39 1985 263 270
-
(1985)
Research in Veterinary Science
, vol.39
, pp. 263-270
-
-
Riemersma, D.J.1
Schamhardt, H.C.2
-
24
-
-
0032411731
-
Influence of sensor size on the accuracy of in vivo ligament and tendon force measurements
-
M. Rupert, E. Grood, T. Byczkoswki, and M. Levy Influence of sensor size on the accuracy of in vivo ligament and tendon force measurements Journal of Biomechanical Engineering 120 1998 764 769
-
(1998)
Journal of Biomechanical Engineering
, vol.120
, pp. 764-769
-
-
Rupert, M.1
Grood, E.2
Byczkoswki, T.3
Levy, M.4
-
25
-
-
0002224196
-
Properties of tendons and ligaments
-
R. Skalak S. Chien McGraw-Hill New York
-
A. Viidik Properties of tendons and ligaments R. Skalak S. Chien Handbook of Bioengineering 1987 McGraw-Hill New York 6.1 6.19
-
(1987)
Handbook of Bioengineering
, pp. 61-619
-
-
Viidik, A.1
|