메뉴 건너뛰기




Volumn 9, Issue 2 SPEC. ISS., 2005, Pages 62-67

Vertebroplasty

Author keywords

Osteoporosis; Pain relief; Percutaneous vertebroplasty

Indexed keywords

POLY(METHYL METHACRYLATE);

EID: 23444434929     PISSN: 1084208X     EISSN: None     Source Type: Journal    
DOI: 10.1053/j.trap.2005.05.003     Document Type: Article
Times cited : (10)

References (22)
  • 1
    • 0141482064 scopus 로고    scopus 로고
    • Minimally invasive procedures for disorders of the lumbar spine
    • H.G. Deen, D.S. Fenton, T.J. Lamer Minimally invasive procedures for disorders of the lumbar spine Mayo Clin Proc 78 2003 1249 1256
    • (2003) Mayo Clin Proc , vol.78 , pp. 1249-1256
    • Deen, H.G.1    Fenton, D.S.2    Lamer, T.J.3
  • 2
    • 0043069471 scopus 로고    scopus 로고
    • Minimally invasive treatments of osteoporotic vertebral compression fractures
    • F.M. Phillips Minimally invasive treatments of osteoporotic vertebral compression fractures Spine 28 2003 545 553
    • (2003) Spine , vol.28 , pp. 545-553
    • Phillips, F.M.1
  • 3
    • 0031431778 scopus 로고    scopus 로고
    • Future directions: Augmentation of osteoporotic vertebral bodies
    • M.P. Bostrom, J.M. Lane Future directions augmentation of osteoporotic vertebral bodies Spine 22 1997 38S 42S
    • (1997) Spine , vol.22
    • Bostrom, M.P.1    Lane, J.M.2
  • 4
    • 0021250999 scopus 로고
    • Local neurotoxicity of methyl methacrylate among dental technicians
    • A.M. Sappalainen, R. Rajaniemi Local neurotoxicity of methyl methacrylate among dental technicians Am J Ind Med 5 1984 471 477
    • (1984) Am J Ind Med , vol.5 , pp. 471-477
    • Sappalainen, A.M.1    Rajaniemi, R.2
  • 5
    • 0037278975 scopus 로고    scopus 로고
    • Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures
    • J.S. Yeom, W.J. Kim, W.S. Choy Leakage of cement in percutaneous transpedicular vertebroplasty for painful osteoporotic compression fractures J Bone Joint Surg [Br] 85B 2003 83 89
    • (2003) J Bone Joint Surg [Br] , vol.85 , pp. 83-89
    • Yeom, J.S.1    Kim, W.J.2    Choy, W.S.3
  • 6
    • 0141780978 scopus 로고    scopus 로고
    • Early radiographic and clinical results of balloon Kyphoplasty for the treatment of osteoporotic vertebral fractures
    • F.M. Phillips, E. Ho, M. Campbell-Hupp Early radiographic and clinical results of balloon Kyphoplasty for the treatment of osteoporotic vertebral fractures Spine 19 2003 2260 2267
    • (2003) Spine , vol.19 , pp. 2260-2267
    • Phillips, F.M.1    Ho, E.2    Campbell-Hupp, M.3
  • 7
    • 1842459467 scopus 로고    scopus 로고
    • Ex vivo measurement of intravertebral pressure during vertebroplasty
    • S. Tomita, S. Molloy, M. Abe Ex vivo measurement of intravertebral pressure during vertebroplasty Spine 29 2004 723 725
    • (2004) Spine , vol.29 , pp. 723-725
    • Tomita, S.1    Molloy, S.2    Abe, M.3
  • 8
    • 8444228488 scopus 로고    scopus 로고
    • A review of complications associated with vertebroplasty and kyphoplasty as reported to the food and drug administration medical device related web site
    • D.A. Nussbaum, P. Gailloud, K. Murphy A review of complications associated with vertebroplasty and kyphoplasty as reported to the food and drug administration medical device related web site J Vasc Interv Radiol 15 2004 1185 1192
    • (2004) J Vasc Interv Radiol , vol.15 , pp. 1185-1192
    • Nussbaum, D.A.1    Gailloud, P.2    Murphy, K.3
  • 9
    • 23444443253 scopus 로고    scopus 로고
    • Society of Interventional Radiology Quality improvement guidelines for percutaneuos vertebroplasty
    • K.J. McGraw, J. Cardella, J.D. Barr Society of Interventional Radiology Quality improvement guidelines for percutaneuos vertebroplasty J Vasc Interv Radiol 14 2003 S311 S315
    • (2003) J Vasc Interv Radiol , vol.14
    • McGraw, K.J.1    Cardella, J.2    Barr, J.D.3
  • 10
    • 0030801524 scopus 로고    scopus 로고
    • Percutaneous vertebral surgery: Techniques and indications
    • J. Chiras, C. Depriester, A. Weill Percutaneous vertebral surgery techniques and indications J Neuroradiol 24 1997 45 59
    • (1997) J Neuroradiol , vol.24 , pp. 45-59
    • Chiras, J.1    Depriester, C.2    Weill, A.3
  • 11
    • 0036121313 scopus 로고    scopus 로고
    • Dose-dependent epidural leakage of polymethacrylate after percutaneous vertebroplasty in patients with osteoportic vertebral compression fractures
    • K.S. Ryu, C.K. Park, M.C. Kim Dose-dependent epidural leakage of polymethacrylate after percutaneous vertebroplasty in patients with osteoportic vertebral compression fractures J Neurosurg (Spine) 96 2002 56 61
    • (2002) J Neurosurg (Spine) , vol.96 , pp. 56-61
    • Ryu, K.S.1    Park, C.K.2    Kim, M.C.3
  • 12
    • 0141520526 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty: Complication avoidance and technique optimization
    • J.M. Mathis Percutaneous vertebroplasty complication avoidance and technique optimization AJNR Am J Neuroradiol 24 2003 1697 1706
    • (2003) AJNR Am J Neuroradiol , vol.24 , pp. 1697-1706
    • Mathis, J.M.1
  • 13
    • 0034879165 scopus 로고    scopus 로고
    • Transient arterial hypotension induced by polymethylmethacrylate injection during percutaneous vertebroplasty
    • C. Vasconcelos, P. Gailloud, J.B. Martin Transient arterial hypotension induced by polymethylmethacrylate injection during percutaneous vertebroplasty J Vasc Interv Radiol 12 2001 1001 1002
    • (2001) J Vasc Interv Radiol , vol.12 , pp. 1001-1002
    • Vasconcelos, C.1    Gailloud, P.2    Martin, J.B.3
  • 14
    • 0036098563 scopus 로고    scopus 로고
    • Paradoxical cerebral arterial embolization of cement during intraoperative vertebroplasty: Case report
    • R. Scroop, J. Eskridge, G.W. Britz Paradoxical cerebral arterial embolization of cement during intraoperative vertebroplasty case report AJNR Am J Neuroradiol 23 2002 868 870
    • (2002) AJNR Am J Neuroradiol , vol.23 , pp. 868-870
    • Scroop, R.1    Eskridge, J.2    Britz, G.W.3
  • 15
    • 0033366518 scopus 로고    scopus 로고
    • Pulmonary embolism caused by acrylic cement: A rare complication of percutaneous vertebroplasty
    • B. Padovani, O. Kasriel, P. Brunner Pulmonary embolism caused by acrylic cement a rare complication of percutaneous vertebroplasty AJNR Am J Neuroradiol 20 1999 375 377
    • (1999) AJNR Am J Neuroradiol , vol.20 , pp. 375-377
    • Padovani, B.1    Kasriel, O.2    Brunner, P.3
  • 16
    • 0036780934 scopus 로고    scopus 로고
    • Pulmonary embolism of polymethacrylate after percutaneous vertebroplasty. a report of three cases
    • J.S. Jang, S.H. Lee, S.K. Jung Pulmonary embolism of polymethacrylate after percutaneous vertebroplasty. A report of three cases Spine 27 2002 E416 E418
    • (2002) Spine , vol.27
    • Jang, J.S.1    Lee, S.H.2    Jung, S.K.3
  • 17
    • 2442519653 scopus 로고    scopus 로고
    • Successful management of a large pulmonary cement embolus after percutaneous vertebroplasty: A case report
    • K. François, Y. Taeymans, B. Poffyn Successful management of a large pulmonary cement embolus after percutaneous vertebroplasty a case report Spine 28 2003 E424 E425
    • (2003) Spine , vol.28
    • François, K.1    Taeymans, Y.2    Poffyn, B.3
  • 18
    • 0036785755 scopus 로고    scopus 로고
    • A lethal pulmonary embolism during percutaneous vertebroplasty
    • H.L. Chen, C.S. Wong, S.T. Ho A lethal pulmonary embolism during percutaneous vertebroplasty Anesth Analg 95 2002 1060 1062
    • (2002) Anesth Analg , vol.95 , pp. 1060-1062
    • Chen, H.L.1    Wong, C.S.2    Ho, S.T.3
  • 19
    • 0031545893 scopus 로고    scopus 로고
    • Percutaneous methylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: Technical aspects
    • M.E. Jensen, A.J. Evans, J.M. Mathis Percutaneous methylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures technical aspects AJNR Am J Neuroradiol 18 1997 1897 1904
    • (1997) AJNR Am J Neuroradiol , vol.18 , pp. 1897-1904
    • Jensen, M.E.1    Evans, A.J.2    Mathis, J.M.3
  • 20
    • 0034918914 scopus 로고    scopus 로고
    • Major neurological complications following percutaneous vertebroplasty with polymethylmethacrylate. a case report
    • K.D. Harrington Major neurological complications following percutaneous vertebroplasty with polymethylmethacrylate. A case report J Bone Joint Surg [Am] 83A 2001 1070 1073
    • (2001) J Bone Joint Surg [Am] , vol.83 , pp. 1070-1073
    • Harrington, K.D.1
  • 21
    • 0037220878 scopus 로고    scopus 로고
    • Surgical removal of epidural and intradural polymethylmethacrylate extravasation complicating percutaneous vertebroplasty for an osteoporotic lumbar compression fracture
    • S. Shapiro, T. Abel, S. Purvines Surgical removal of epidural and intradural polymethylmethacrylate extravasation complicating percutaneous vertebroplasty for an osteoporotic lumbar compression fracture J Neurosurg (Spine) 98 2003 90 92
    • (2003) J Neurosurg (Spine) , vol.98 , pp. 90-92
    • Shapiro, S.1    Abel, T.2    Purvines, S.3
  • 22
    • 0036790721 scopus 로고    scopus 로고
    • An in vivo comparison of the potential for extravertebral cement leak after vertebroplasty and kyphoplasty
    • F.M. Phillips, F.T. Wetzel, I. Lieberman An in vivo comparison of the potential for extravertebral cement leak after vertebroplasty and kyphoplasty Spine 27 2002 2173 2179
    • (2002) Spine , vol.27 , pp. 2173-2179
    • Phillips, F.M.1    Wetzel, F.T.2    Lieberman, I.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.