메뉴 건너뛰기




Volumn 113, Issue 4, 2004, Pages 1126-1130

Reducing allogenic blood transfusions during pediatric cranial vault surgical procedures: A prospective analysis of blood recycling

Author keywords

[No Author keywords available]

Indexed keywords

ADOLESCENT; ADULT; ALLOGENIC BLOOD TRANSFUSION; ARTICLE; BLEEDING; BLOOD TRANSFUSION; BLOOD TRANSFUSION REACTION; BLOOD VOLUME; CHILD; CONTROLLED STUDY; CRANIOFACIAL SYNOSTOSIS; DEVICE; HEMOCONCENTRATION; HUMAN; INFANT; MAJOR CLINICAL STUDY; OPERATION DURATION; PEDIATRIC SURGERY; PRIORITY JOURNAL; PROSPECTIVE STUDY; RECYCLING; SAFETY; SKULL SURGERY; SURGICAL TECHNIQUE; BLOOD AUTOTRANSFUSION; METHODOLOGY; PERIOPERATIVE PERIOD; PRESCHOOL CHILD;

EID: 2342655847     PISSN: 00321052     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.PRS.0000110324.31791.5C     Document Type: Article
Times cited : (78)

References (27)
  • 1
    • 0028834248 scopus 로고
    • Intraoperative autologous blood transfusion in the surgical correction of craniosynostosis
    • Jimenez, D. F., and Barone, C. M. Intraoperative autologous blood transfusion in the surgical correction of craniosynostosis. Neurosurgery 37: 1075, 1995.
    • (1995) Neurosurgery , vol.37 , pp. 1075
    • Jimenez, D.F.1    Barone, C.M.2
  • 2
    • 0029900917 scopus 로고    scopus 로고
    • Intraoperative autologous blood transfusion in the surgical correction of craniosynostosis
    • Meyer, P., Renier, D., and Arnaud, E. Intraoperative autologous blood transfusion in the surgical correction of craniosynostosis (Letter). Neurosurgery 39: 213, 1996.
    • (1996) Neurosurgery , vol.39 , pp. 213
    • Meyer, P.1    Renier, D.2    Arnaud, E.3
  • 3
    • 0036141305 scopus 로고    scopus 로고
    • The use of intraoperative autotransfusion during cranial vault remodeling for craniosynostosis
    • Deva, A. K., Hopper, R. A., Landecker, A., et al. The use of intraoperative autotransfusion during cranial vault remodeling for craniosynostosis. Plast. Reconstr. Surg. 109: 58, 2002.
    • (2002) Plast. Reconstr. Surg. , vol.109 , pp. 58
    • Deva, A.K.1    Hopper, R.A.2    Landecker, A.3
  • 4
    • 0033039704 scopus 로고    scopus 로고
    • Blood loss and transfusion practice in the perioperative management of craniosynostosis repair
    • Faberowski, L. W., Black, S., and Mickle, J. P. Blood loss and transfusion practice in the perioperative management of craniosynostosis repair. J. Neurosurg. Anesthesiol. 11: 167, 1999.
    • (1999) J. Neurosurg. Anesthesiol. , vol.11 , pp. 167
    • Faberowski, L.W.1    Black, S.2    Mickle, J.P.3
  • 5
    • 7344243726 scopus 로고    scopus 로고
    • Perioperative specific management of blood volume loss in craniosynostosis surgery
    • Kang, J. K., Lee, S. W., Baik, M. W., et al. Perioperative specific management of blood volume loss in craniosynostosis surgery. Child. Nerv. Syst. 14: 297, 1998.
    • (1998) Child. Nerv. Syst. , vol.14 , pp. 297
    • Kang, J.K.1    Lee, S.W.2    Baik, M.W.3
  • 6
    • 0028872741 scopus 로고
    • Transfusion requirements for craniosynostosis surgery in infants
    • Eaton, A. C., Marsh, J. L., and Pilgram, T. K. Transfusion requirements for craniosynostosis surgery in infants. Plast. Reconstr. Surg. 95: 277, 1995.
    • (1995) Plast. Reconstr. Surg. , vol.95 , pp. 277
    • Eaton, A.C.1    Marsh, J.L.2    Pilgram, T.K.3
  • 7
    • 0027369774 scopus 로고
    • Blood loss during repair of craniosynostosis
    • Meyer, P., Renier, D., Arnaud, E., et al. Blood loss during repair of craniosynostosis. Br. J. Anaesth. 71: 854, 1993.
    • (1993) Br. J. Anaesth. , vol.71 , pp. 854
    • Meyer, P.1    Renier, D.2    Arnaud, E.3
  • 8
    • 4444374750 scopus 로고
    • Lethal complications after craniofacial surgery
    • D. Marchac (Ed.). Bologna: Monduzzi
    • Marchac, D., Renier, D., and Guerrero, P. Lethal complications after craniofacial surgery. In D. Marchac (Ed.), Craniofacial Surgery, 6th Ed. Bologna: Monduzzi, 1995. Pp. 225-228.
    • (1995) Craniofacial Surgery, 6th Ed , pp. 225-228
    • Marchac, D.1    Renier, D.2    Guerrero, P.3
  • 9
    • 0036113291 scopus 로고    scopus 로고
    • The use of recombinant erythropoietin in the reduction of blood transfusion rates in craniosynostosis repair in infants and children
    • Fearon, J. A., and Weinthal, J. The use of recombinant erythropoietin in the reduction of blood transfusion rates in craniosynostosis repair in infants and children. Plast. Reconstr. Surg. 109: 2190, 2002.
    • (2002) Plast. Reconstr. Surg. , vol.109 , pp. 2190
    • Fearon, J.A.1    Weinthal, J.2
  • 10
    • 0026510292 scopus 로고
    • Bacteriologic and endotoxin analysis of salvaged blood used in autologous transfusions during cardiac surgery
    • Bland, L. A., Villarino, M. E., Arduino, M. J., et al. Bacteriologic and endotoxin analysis of salvaged blood used in autologous transfusions during cardiac surgery. J. Thorac. Cardiovasc. Surg. 103: 582, 1992.
    • (1992) J. Thorac. Cardiovasc. Surg. , vol.103 , pp. 582
    • Bland, L.A.1    Villarino, M.E.2    Arduino, M.J.3
  • 11
    • 0035187260 scopus 로고    scopus 로고
    • Current status of bacterial contamination of autologous blood for transfusion
    • Sugai, Y., Sugai, K., and Fuse, A. Current status of bacterial contamination of autologous blood for transfusion. Transfus. Apheresis Sci. 24: 255, 2001.
    • (2001) Transfus. Apheresis Sci. , vol.24 , pp. 255
    • Sugai, Y.1    Sugai, K.2    Fuse, A.3
  • 12
    • 0035220857 scopus 로고    scopus 로고
    • Does cell-saver blood administration and free hemoglobin load cause renal dysfunction?
    • Klodell, C. T., Richardson, J. D., Bergamini, T. M., et al. Does cell-saver blood administration and free hemoglobin load cause renal dysfunction? Am. Surg. 67: 44, 2001.
    • (2001) Am. Surg. , vol.67 , pp. 44
    • Klodell, C.T.1    Richardson, J.D.2    Bergamini, T.M.3
  • 13
    • 0034529893 scopus 로고    scopus 로고
    • Relative cost of autologous red cell salvage versus allogenic red cell transfusion during abdominal aortic aneurysm repair
    • Gardner, A., Gibbs, N., Evans, C., and Bell, R. Relative cost of autologous red cell salvage versus allogenic red cell transfusion during abdominal aortic aneurysm repair. Anaesth. Intensive Care 28: 646, 2000.
    • (2000) Anaesth. Intensive Care , vol.28 , pp. 646
    • Gardner, A.1    Gibbs, N.2    Evans, C.3    Bell, R.4
  • 14
    • 0033658835 scopus 로고    scopus 로고
    • Should the cell saver auto transfusion system be routinely used in elective aortic surgery?
    • Serrano, F. J., Monux, G., and Aroca, M. Should the cell saver autotransfusion system be routinely used in elective aortic surgery? Ann. Vasc. Surg. 14: 663, 2000.
    • (2000) Ann. Vasc. Surg. , vol.14 , pp. 663
    • Serrano, F.J.1    Monux, G.2    Aroca, M.3
  • 15
    • 0036276469 scopus 로고    scopus 로고
    • Economic evaluation of a randomized clinical trial of haemodilution with cell salvage in aortic surgery
    • Haynes, S. L., Torella, F., Wong, C. L., et al. Economic evaluation of a randomized clinical trial of haemodilution with cell salvage in aortic surgery. Br. J. Surg. 89: 731, 2002.
    • (2002) Br. J. Surg. , vol.89 , pp. 731
    • Haynes, S.L.1    Torella, F.2    Wong, C.L.3
  • 17
    • 0033361142 scopus 로고    scopus 로고
    • Autologous transfusion, 3 years on: What is new? What has happened?
    • Allain, J-P., Akehurst, R. L., and Hunter, J. M. Autologous transfusion, 3 years on: What is new? What has happened? Transfusion 39: 910, 1999.
    • (1999) Transfusion , vol.39 , pp. 910
    • Allain, J.-P.1    Akehurst, R.L.2    Hunter, J.M.3
  • 18
    • 0034871617 scopus 로고    scopus 로고
    • Are leukocytes in salvaged washed autologous blood harmful for the recipient? The results of a pilot study
    • Innerhofer, P., Wiedermann, F. J., Tiefenthaler, W., et al. Are leukocytes in salvaged washed autologous blood harmful for the recipient? The results of a pilot study. Anesth. Analg. 93: 566, 2001.
    • (2001) Anesth. Analg. , vol.93 , pp. 566
    • Innerhofer, P.1    Wiedermann, F.J.2    Tiefenthaler, W.3
  • 19
    • 0036140975 scopus 로고    scopus 로고
    • Autologous versus allogenic transfusion in aortic surgery
    • Wong, J. C. L. ,Torella, F., and Haynes, S. L. Autologous versus allogenic transfusion in aortic surgery. Ann. Surg. 235: 145, 2002.
    • (2002) Ann. Surg. , vol.235 , pp. 145
    • Wong, J.C.L.1    Torella, F.2    Haynes, S.L.3
  • 20
    • 0033490766 scopus 로고    scopus 로고
    • The results of intraoperative autotransfusion in orthopaedic surgery
    • Benli, I. T., Akalin, S., Duman, E., et al. The results of intraoperative autotransfusion in orthopaedic surgery. Bull. Hosp. Joint Dis. 58: 184, 1999.
    • (1999) Bull. Hosp. Joint Dis. , vol.58 , pp. 184
    • Benli, I.T.1    Akalin, S.2    Duman, E.3
  • 21
    • 0344172595 scopus 로고    scopus 로고
    • A meta-analysis of the effectiveness of cell salvage to minimize perioperative allogenic blood transfusion in cardiac and orthopedic surgery
    • Huët, C., Salmi, L. R., Fergusson, D., et al. A meta-analysis of the effectiveness of cell salvage to minimize perioperative allogenic blood transfusion in cardiac and orthopedic surgery. Anesth. Analg. 89: 861, 1999.
    • (1999) Anesth. Analg. , vol.89 , pp. 861
    • Huët, C.1    Salmi, L.R.2    Fergusson, D.3
  • 22
    • 0032717211 scopus 로고    scopus 로고
    • Impact of red cell salvage on transfusion requirements during elective abdominal aortic aneurysm repair
    • Szalay, D., Wong, D., and Lindsay, T. Impact of red cell salvage on transfusion requirements during elective abdominal aortic aneurysm repair. Ann. Vasc. Surg. 13: 576, 1999.
    • (1999) Ann. Vasc. Surg. , vol.13 , pp. 576
    • Szalay, D.1    Wong, D.2    Lindsay, T.3
  • 23
    • 0033947902 scopus 로고    scopus 로고
    • Efficacy of postoperative blood salvage following total hip arthroplasty in patients with and without deposited autologous units
    • Grosvenor, D., Goyal, V., and Goodman, S. Efficacy of postoperative blood salvage following total hip arthroplasty in patients with and without deposited autologous units. J. Bone Joint Surg. (Am.) 82: 951, 2000.
    • (2000) J. Bone Joint Surg. (Am.) , vol.82 , pp. 951
    • Grosvenor, D.1    Goyal, V.2    Goodman, S.3
  • 24
    • 0033923863 scopus 로고    scopus 로고
    • Intraoperative autotransfusion for repair of unruptured aneurysms of the infrarenal abdominal aorta: A multicenter study of 203 patients
    • Patra, P., Chaillou, P., and Bizouarn, P. Intraoperative autotransfusion for repair of unruptured aneurysms of the infrarenal abdominal aorta: A multicenter study of 203 patients. J. Cardiovasc. Surg. 41: 407, 2000.
    • (2000) J. Cardiovasc. Surg. , vol.41 , pp. 407
    • Patra, P.1    Chaillou, P.2    Bizouarn, P.3
  • 25
    • 0035512120 scopus 로고    scopus 로고
    • Intraoperative cell salvage in radical retropubic prostatectomy
    • Gray, C. L., Amling, C. L., Polston, G. R., Powell, C. R., and Kane, C. J. Intraoperative cell salvage in radical retropubic prostatectomy. Urology 58: 740, 2001.
    • (2001) Urology , vol.58 , pp. 740
    • Gray, C.L.1    Amling, C.L.2    Polston, G.R.3    Powell, C.R.4    Kane, C.J.5
  • 27
    • 0036191508 scopus 로고    scopus 로고
    • Intraoperative autotransfusion in hip arthroplasty
    • Shulman, G., Grecula, M. J., and Hadjipavlou, A. G. Intraoperative autotransfusion in hip arthroplasty. Clin. Orthop. 396: 119, 2002.
    • (2002) Clin. Orthop. , vol.396 , pp. 119
    • Shulman, G.1    Grecula, M.J.2    Hadjipavlou, A.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.