메뉴 건너뛰기




Volumn 100, Issue 3, 2004, Pages 347-351

Optical CO2 sensor with the combination of colorimetric change of α-naphtholphthalein and internal reference fluorescent porphyrin dye

Author keywords

Naphtholphthalein; Colorimetric change; Optical CO2 sensor; pH indicator; Porphyrin

Indexed keywords

ABSORPTION; CARBON DIOXIDE; CELLULOSE; COLORIMETRIC ANALYSIS; DYES; FLUORESCENCE; HYDRATION; HYSTERESIS; NITROGEN; OPTICAL SENSORS; PH EFFECTS; POLYSTYRENES; PORPHYRINS; SOLUTIONS;

EID: 2342648105     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2004.02.003     Document Type: Article
Times cited : (64)

References (18)
  • 3
    • 0001532670 scopus 로고
    • Electrodes for blood pO2 and pCO2 determination
    • Severinghaus J.W., Bradley A.F. Electrodes for blood pO2 and pCO2 determination. J. Appl. Physiol. 13:1958;515-520.
    • (1958) J. Appl. Physiol. , vol.13 , pp. 515-520
    • Severinghaus, J.W.1    Bradley, A.F.2
  • 4
    • 0038535076 scopus 로고
    • Thin plastic film colorimetric sensors for carbon dioxide: Effect of plasticizer on response
    • Mills A., Monaf L. Thin plastic film colorimetric sensors for carbon dioxide: effect of plasticizer on response. Analyst. 121:1986;1-6.
    • (1986) Analyst , vol.121 , pp. 1-6
    • Mills, A.1    Monaf, L.2
  • 5
    • 11944267513 scopus 로고
    • Equilibrium study on colorimetric plastic film sensor for carbon dioxide
    • Mills A., Chang Q., McMurray H.M. Equilibrium study on colorimetric plastic film sensor for carbon dioxide. Anal. Chem. 64:1992;1383-1389.
    • (1992) Anal. Chem. , vol.64 , pp. 1383-1389
    • Mills, A.1    Chang, Q.2    McMurray, H.M.3
  • 6
    • 0031084102 scopus 로고    scopus 로고
    • Breath-by-breath measurement of carbon dioxide using a plastic film optical sensor
    • Mills A., Lepre A., Wild L. Breath-by-breath measurement of carbon dioxide using a plastic film optical sensor. Sens. Actuator B. 38/39:1997;419-425.
    • (1997) Sens. Actuator B , vol.38-39 , pp. 419-425
    • Mills, A.1    Lepre, A.2    Wild, L.3
  • 7
    • 0024596026 scopus 로고
    • Fiber-optic sensor for carbon dioxide with a pH indicator dispersed in a poly(ethyleneglycol) membrane
    • Kawabata Y., Kamichika T., Imasaka T., Ishibashi N. Fiber-optic sensor for carbon dioxide with a pH indicator dispersed in a poly(ethyleneglycol) membrane. Anal. Chim. Acta. 219:1989;223-229.
    • (1989) Anal. Chim. Acta , vol.219 , pp. 223-229
    • Kawabata, Y.1    Kamichika, T.2    Imasaka, T.3    Ishibashi, N.4
  • 8
    • 0034273229 scopus 로고    scopus 로고
    • Optical pH, oxygen and carbon dioxide monitoring using a microdialysis approach
    • Cooney C.G., Towe B.C., Eyster C.R. Optical pH, oxygen and carbon dioxide monitoring using a microdialysis approach. Sens. Actuator B. 69:2000;183-188.
    • (2000) Sens. Actuator B , vol.69 , pp. 183-188
    • Cooney, C.G.1    Towe, B.C.2    Eyster, C.R.3
  • 10
    • 2142744124 scopus 로고
    • A carbon dioxide sensor based on fluorescence
    • Zhujun Z., Seitz R. A carbon dioxide sensor based on fluorescence. Anal. Chim. Acta. 160:1984;305-309.
    • (1984) Anal. Chim. Acta , vol.160 , pp. 305-309
    • Zhujun, Z.1    Seitz, R.2
  • 12
    • 0000636562 scopus 로고
    • Fluorescence plastic film sensor for carbon dioxide
    • Mills A., Chang Q. Fluorescence plastic film sensor for carbon dioxide. Analyst. 118:1993;839-843.
    • (1993) Analyst , vol.118 , pp. 839-843
    • Mills, A.1    Chang, Q.2
  • 15
    • 0038248911 scopus 로고    scopus 로고
    • 2 using thymol blue and europium(III) complex composite film
    • 2 using thymol blue and europium(III) complex composite film. Sens. Actuator B. 92:2003;98-101.
    • (2003) Sens. Actuator B , vol.92 , pp. 98-101
    • Nakamura, N.1    Amao, Y.2
  • 16
    • 0041660625 scopus 로고    scopus 로고
    • 2 sensor with the combination of colorimetric change of pH indicator and internal reference luminescent dye
    • 2 sensor with the combination of colorimetric change of pH indicator and internal reference luminescent dye. Bull. Chem. Soc. Jpn. 76:2003;1459-1462.
    • (2003) Bull. Chem. Soc. Jpn. , vol.76 , pp. 1459-1462
    • Nakamura, N.1    Amao, Y.2
  • 17
    • 2342625087 scopus 로고    scopus 로고
    • Optical sensor for carbon dioxide combining colorimetric change of a pH indicator and a reference luminescent dye
    • Nakamura N., Amao Y. Optical sensor for carbon dioxide combining colorimetric change of a pH indicator and a reference luminescent dye. Anal. Bioanal. Chem. 376:2003;642-646.
    • (2003) Anal. Bioanal. Chem. , vol.376 , pp. 642-646
    • Nakamura, N.1    Amao, Y.2
  • 18
    • 37049086204 scopus 로고
    • Fiber optic oxygen sensor based on fluorescence quenching of evanescent-wave excited ruthenium complexes in sol-gel derived porous coatings
    • MacCraith B.D., McDonagh C.M., O'Keeffe G., Keyes E.T., Vos J.G., O'Kelly B., McGilp J.F. Fiber optic oxygen sensor based on fluorescence quenching of evanescent-wave excited ruthenium complexes in sol-gel derived porous coatings. The Analyst. 118:1993;385-388.
    • (1993) The Analyst , vol.118 , pp. 385-388
    • Maccraith, B.D.1    McDonagh, C.M.2    O'keeffe, G.3    Keyes, E.T.4    Vos, J.G.5    O'kelly, B.6    McGilp, J.F.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.