메뉴 건너뛰기




Volumn 51, Issue 1 I, 2004, Pages 142-148

Image reconstruction algorithm for a SPECT system with a convergent rotating slat collimator

Author keywords

Analytical algorithm; Convergent slat collimator; Filtered backprojection; Image reconstruction; Single photon emission computed tomography (SPECT)

Indexed keywords

ALGORITHMS; CAMERAS; COMPUTERIZED TOMOGRAPHY; ELECTROMAGNETIC WAVE ATTENUATION; ERROR ANALYSIS; IMAGING TECHNIQUES; OPTICAL COLLIMATORS; PHOTONS;

EID: 2342613548     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2003.823042     Document Type: Article
Times cited : (8)

References (19)
  • 1
    • 0016688743 scopus 로고
    • The fan-beam gamma camera
    • W. I. Keyes, "The fan-beam gamma camera," Phys. Med. Biol., vol. 20, pp. 489-491, 1975.
    • (1975) Phys. Med. Biol. , vol.20 , pp. 489-491
    • Keyes, W.I.1
  • 2
    • 0026582501 scopus 로고
    • Monte Carlo modeling of the performance of a rotating slit-collimator for improved planar gamma-camera imaging
    • S. Webb, D. M. Binnie, M. A. Flower, and R. J. Ott, "Monte Carlo modeling of the performance of a rotating slit-collimator for improved planar gamma-camera imaging," Phys. Med. Biol., vol. 37, pp. 1095-1108, 1992.
    • (1992) Phys. Med. Biol. , vol.37 , pp. 1095-1108
    • Webb, S.1    Binnie, D.M.2    Flower, M.A.3    Ott, R.J.4
  • 3
    • 0027156859 scopus 로고
    • Geometric efficiency of a rotating slit-collimator for improved planar gamma-camera imaging
    • S. Webb, M. A. Flower, and R. J. Ott, "Geometric efficiency of a rotating slit-collimator for improved planar gamma-camera imaging," Phys. Med. Biol., vol. 38, pp. 627-638, 1993.
    • (1993) Phys. Med. Biol. , vol.38 , pp. 627-638
    • Webb, S.1    Flower, M.A.2    Ott, R.J.3
  • 4
    • 0028958333 scopus 로고
    • The experimental evaluation of a prototype rotating slat collimator for planar gamma camera imaging
    • M. A. Lodge, D. M. Binnie, M. A. Flower, and S. Webb, "The experimental evaluation of a prototype rotating slat collimator for planar gamma camera imaging," Phys. Med. Biol., vol. 40, pp. 427-448, 1995.
    • (1995) Phys. Med. Biol. , vol.40 , pp. 427-448
    • Lodge, M.A.1    Binnie, D.M.2    Flower, M.A.3    Webb, S.4
  • 5
    • 0030215789 scopus 로고    scopus 로고
    • A prototype rotating slat collimator for single photon emission computed tomography
    • M. A. Lodge, S. Webb, M. A. Flower, and D. M. Binnie, "A prototype rotating slat collimator for single photon emission computed tomography," IEEE Trans. Med. Imaging, vol. 15, pp. 500-511, 1996.
    • (1996) IEEE Trans. Med. Imaging , vol.15 , pp. 500-511
    • Lodge, M.A.1    Webb, S.2    Flower, M.A.3    Binnie, D.M.4
  • 15
    • 0004775148 scopus 로고    scopus 로고
    • Eigen analysis of cone-beam scanning geometries
    • ser. Computational Imaging and Vision, P. Orangeat and J.-L. Amans, Eds. Norwell, MA: Kluwer
    • G. L. Zeng, G. T. Gullberg, and S. A. Foresti, "Eigen analysis of cone-beam scanning geometries," in Three-Dimensional Imaging Reconstruction in Radiology and Nuclear Medicine, ser. Computational Imaging and Vision, P. Orangeat and J.-L. Amans, Eds. Norwell, MA: Kluwer, 1996, pp. 75-86.
    • (1996) Three-dimensional Imaging Reconstruction in Radiology and Nuclear Medicine , pp. 75-86
    • Zeng, G.L.1    Gullberg, G.T.2    Foresti, S.A.3
  • 16
    • 0001598883 scopus 로고
    • On two approaches to 3D reconstruction in NMR zeugmatography
    • G. T. Herman and F. Natterer, Eds. New York: Springer-Verlag
    • R. B. Marr, C. Chen, and P. C. Lauterbur, "On two approaches to 3D reconstruction in NMR zeugmatography," in Mathematical Aspects of Computerized Tomography, G. T. Herman and F. Natterer, Eds. New York: Springer-Verlag, 1980.
    • (1980) Mathematical Aspects of Computerized Tomography
    • Marr, R.B.1    Chen, C.2    Lauterbur, P.C.3
  • 17
    • 0002018761 scopus 로고
    • Mathematical framework of cone-beam 3D reconstruction via the first derivative of the Radon transform
    • G. T. Herman, A. K. Louis, and F. Natterer, Eds. New York: Springer-Verlag
    • P. Orangeat, "Mathematical framework of cone-beam 3D reconstruction via the first derivative of the Radon transform," in Mathematical Methods in Tomography, G. T. Herman, A. K. Louis, and F. Natterer, Eds. New York: Springer-Verlag, 1990.
    • (1990) Mathematical Methods in Tomography
    • Orangeat, P.1
  • 19
    • 0142094973 scopus 로고    scopus 로고
    • Single photon emission local tomography
    • G. L. Zeng and D. Gagnon, "Single photon emission local tomography," J. Nucl. Med., vol. 43, p. 145P, 2002.
    • (2002) J. Nucl. Med. , vol.43
    • Zeng, G.L.1    Gagnon, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.