메뉴 건너뛰기




Volumn 35, Issue 6, 2004, Pages 596-598

Carbon fibre plates in the treatment of femoral periprosthetic fractures

Author keywords

Carbon fibre plates; Periprosthetic fractures; Total hip replacement

Indexed keywords

CARBON FIBER;

EID: 2342600251     PISSN: 00201383     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.injury.2003.10.014     Document Type: Article
Times cited : (30)

References (11)
  • 1
    • 0036219735 scopus 로고    scopus 로고
    • The use of a carbon fibre plate for periprosthetic supracondylar femoral fractures
    • Al-Shawi A.K., Smith S.P., Anderson G.H. The use of a carbon fibre plate for periprosthetic supracondylar femoral fractures. J. Arthroplasty. 17(3):2002;320-324
    • (2002) J. Arthroplasty. , vol.17 , Issue.3 , pp. 320-324
    • Al-Shawi, A.K.1    Smith, S.P.2    Anderson, G.H.3
  • 2
    • 0019188009 scopus 로고
    • Carbon fibre reinforced epoxy as high strength low modulus material for internal fixation plates
    • Bradley J.S., Hastings G.W., Johnson-Nurse C. Carbon fibre reinforced epoxy as high strength low modulus material for internal fixation plates. Biomaterials. 1:1980;38-40
    • (1980) Biomaterials , vol.1 , pp. 38-40
    • Bradley, J.S.1    Hastings, G.W.2    Johnson-Nurse, C.3
  • 3
    • 0027958880 scopus 로고
    • Biological plate osteosynthesis
    • Gautier E., Ganz R. Biological plate osteosynthesis. Zentrabl. Chir. 119(8):1994;564-572
    • (1994) Zentrabl. Chir. , vol.119 , Issue.8 , pp. 564-572
    • Gautier, E.1    Ganz, R.2
  • 4
    • 0021918032 scopus 로고
    • The use of short carbon fibre reinforced thermoplastic plates for fracture fixation
    • Gillett N., Brown S.A., Dumbleton J.H., Pool R.P. The use of short carbon fibre reinforced thermoplastic plates for fracture fixation. Biomaterials. 6(2):1985;113-121
    • (1985) Biomaterials , vol.6 , Issue.2 , pp. 113-121
    • Gillett, N.1    Brown, S.A.2    Dumbleton, J.H.3    Pool, R.P.4
  • 5
    • 0022414789 scopus 로고
    • The response of human tissues to carbon reinforced epoxy resin
    • Howard C.B., Tayton K.J., Gibbs A. The response of human tissues to carbon reinforced epoxy resin. J. Bone Jt. Surg. Br. 67(4):1985;656-658
    • (1985) J. Bone Jt. Surg. Br. , vol.67 , Issue.4 , pp. 656-658
    • Howard, C.B.1    Tayton, K.J.2    Gibbs, A.3
  • 6
    • 0019818041 scopus 로고
    • Fracture of the ipsilateral femur in patients with total hip replacement
    • Johannsson J.E., McBroom R., Barrington T.W. Fracture of the ipsilateral femur in patients with total hip replacement. J. Bone Jt. Surg. 63A:1981;1435-1442
    • (1981) J. Bone Jt. Surg. , vol.63 , pp. 1435-1442
    • Johannsson, J.E.1    McBroom, R.2    Barrington, T.W.3
  • 7
    • 30344459755 scopus 로고    scopus 로고
    • Treatment of periprosthetic fractures in association with total hip arthroplasty: A retrospective comparison between revision stem Jukkala-Partio and plate fixation
    • Partio E.K., Solovieva S., Paavilainen T., Hirvensalo E., Alho A. Treatment of periprosthetic fractures in association with total hip arthroplasty: a retrospective comparison between revision stem Jukkala-Partio and plate fixation. Ann. Chir. Gynaecol. 87(3):1998;229-235
    • (1998) Ann. Chir. Gynaecol. , vol.87 , Issue.3 , pp. 229-235
    • Partio, E.K.1    Solovieva, S.2    Paavilainen, T.3    Hirvensalo, E.4    Alho, A.5
  • 8
    • 0028361346 scopus 로고
    • Fractures of the distal femur in the elderly treated with a carbon fibre supracondylar plate
    • Pemberton D.J., Evans P.D., Grant A., McKibbin B. Fractures of the distal femur in the elderly treated with a carbon fibre supracondylar plate. Injury. 25(5):1994;317-321
    • (1994) Injury , vol.25 , Issue.5 , pp. 317-321
    • Pemberton, D.J.1    Evans, P.D.2    Grant, A.3    McKibbin, B.4
  • 9
    • 0024456162 scopus 로고
    • Femoral fracture during non-cemented total hip arthroplasty
    • Schwartz J.T. Jr., Mayer J.G., Engh C.A. Femoral fracture during non-cemented total hip arthroplasty. J. Bone Jt. Surg. 71:1989;1135-1142
    • (1989) J. Bone Jt. Surg. , vol.71 , pp. 1135-1142
    • Schwartz Jr., J.T.1    Mayer, J.G.2    Engh, C.A.3
  • 10
    • 0023510856 scopus 로고
    • Carbon fiber reinforced plastic (CFRP) plates versus stainless steel dynamic compression plates in the treatment of fractures of the tibiae in dogs
    • Skirving A.P., Day R., Macdonald W., McLaren R. Carbon fiber reinforced plastic (CFRP) plates versus stainless steel dynamic compression plates in the treatment of fractures of the tibiae in dogs. Clin. Orthop. 224:1987;117-124
    • (1987) Clin. Orthop. , vol.224 , pp. 117-124
    • Skirving, A.P.1    Day, R.2    MacDonald, W.3    McLaren, R.4
  • 11
    • 0032914966 scopus 로고    scopus 로고
    • Fractures of the femur after hip replacement: The Oregon experience
    • [review]
    • Tower S.S., Beals R.K. Fractures of the femur after hip replacement: the Oregon experience. Orthop Clin. North Am. 30(2):1999;235-247. [review]
    • (1999) Orthop Clin. North Am. , vol.30 , Issue.2 , pp. 235-247
    • Tower, S.S.1    Beals, R.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.