Volumn 59, Issue 5, 2004, Pages 453-458

Non-invasive monitoring of haemoglobin concentration in paediatric surgical patients using near-infrared spectroscopy

Author keywords

Haemoglobin; Intraoperative; Monitoring; Near infrared; Spectroscopy

Indexed keywords

ATRACURIUM; HEMOGLOBIN; NITROUS OXIDE; OPIATE; OXYGEN; SEVOFLURANE;

EID: 2342591459     PISSN: 00032409     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1365-2044.2004.03665.x     Document Type: Article
Times cited : (11)

References (30)
  • 1
    • 2342524204 scopus 로고    scopus 로고
    • Fluid balance: All aspects
    • Sumner E, Hatch D, eds. 2nd edn. London: Arnold
    • Huskisson L. Fluid balance: all aspects. In: Sumner E, Hatch D, eds. Paediatric Anaesthesia, 2nd edn. London: Arnold, 1999: 233-49.
    • (1999) Paediatric Anaesthesia , pp. 233-249
    • Huskisson, L.1
  • 2
    • 0034241553 scopus 로고    scopus 로고
    • Phlebotomy overdraw in the neonatal intensive care nursery
    • Lin JC, Strauss RG, Kulhavy JC, et al. Phlebotomy overdraw in the neonatal intensive care nursery. Pediatrics 2000; 106: E19.
    • (2000) Pediatrics , vol.106
    • Lin, J.C.1    Strauss, R.G.2    Kulhavy, J.C.3
  • 4
    • 0029060006 scopus 로고
    • Performance comparison of several published tissue near-infrared spectroscopy algorithms
    • Matcher SJ, Elwell CE, Cooper CE, Cope M, Delpy DT. Performance comparison of several published tissue near-infrared spectroscopy algorithms. Annals of Biochemistry 1995; 227: 54-68.
    • (1995) Annals of Biochemistry , vol.227 , pp. 54-68
    • Matcher, S.J.1    Elwell, C.E.2    Cooper, C.E.3    Cope, M.4    Delpy, D.T.5
  • 6
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; i: 307-10.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 7
    • 0032957316 scopus 로고    scopus 로고
    • Retrograde cerebral perfusion versus selective cerebral perfusion as evaluated by cerebral oxygen saturation during aortic arch reconstruction
    • Higami T, Kozawa S, Asada T, et al. Retrograde cerebral perfusion versus selective cerebral perfusion as evaluated by cerebral oxygen saturation during aortic arch reconstruction. Annals of Thoracic Surgery 1999; 67: 1091-6.
    • (1999) Annals of Thoracic Surgery , vol.67 , pp. 1091-1096
    • Higami, T.1    Kozawa, S.2    Asada, T.3
  • 12
    • 0030070212 scopus 로고    scopus 로고
    • Cerebral oximetry in patients undergoing carotid endarterectomy under regional anesthesia
    • Samra SK, Dorje P, Zelenock GB, Stanley JC. Cerebral oximetry in patients undergoing carotid endarterectomy under regional anesthesia. Stroke 1996; 27: 49-55.
    • (1996) Stroke , vol.27 , pp. 49-55
    • Samra, S.K.1    Dorje, P.2    Zelenock, G.B.3    Stanley, J.C.4
  • 13
    • 0033779446 scopus 로고    scopus 로고
    • Evaluation of a cerebral oximeter as a monitor of cerebral ischemia during carotid endarterectomy
    • Samra SK, Dy EA, Welch K, et al. Evaluation of a cerebral oximeter as a monitor of cerebral ischemia during carotid endarterectomy. Anesthesiology 2000; 93: 964-70.
    • (2000) Anesthesiology , vol.93 , pp. 964-970
    • Samra, S.K.1    Dy, E.A.2    Welch, K.3
  • 15
    • 0027433475 scopus 로고
    • Reduction of blood loss from diagnostic sampling in critically ill patients using a blood-conserving arterial line system
    • Silver MJ, Li YH, Gragg LA, Jubran F, Stoller JK. Reduction of blood loss from diagnostic sampling in critically ill patients using a blood-conserving arterial line system. Chest 1993; 104: 1711-15.
    • (1993) Chest , vol.104 , pp. 1711-1715
    • Silver, M.J.1    Li, Y.H.2    Gragg, L.A.3    Jubran, F.4    Stoller, J.K.5
  • 16
    • 0033397526 scopus 로고    scopus 로고
    • Important role of nondiagnostic blood loss and blunted erythropoietic response in the anemia of medical intensive care patients
    • von Ahsen N, Muller C, Serke S, Frei U, Eckardt KU. Important role of nondiagnostic blood loss and blunted erythropoietic response in the anemia of medical intensive care patients. Critical Care Medicine 1999; 27: 2630-9.
    • (1999) Critical Care Medicine , vol.27 , pp. 2630-2639
    • von Ahsen, N.1    Muller, C.2    Serke, S.3    Frei, U.4    Eckardt, K.U.5
  • 17
    • 0018872212 scopus 로고
    • Analytic precision in clinical chemistry and medical decisions
    • Elion-Gerritzen WE. Analytic precision in clinical chemistry and medical decisions. American Journal of Clinical Pathology 1980; 73: 183-95.
    • (1980) American Journal of Clinical Pathology , vol.73 , pp. 183-195
    • Elion-Gerritzen, W.E.1
  • 18
    • 0019306543 scopus 로고
    • Limits of performance for measurement of blood haemoglobin concentration, number concentration of erythrocytes, and erythrocyte Volume fraction in interlaboratory trials. Results of the Finnish proficiency testing programme in haematology
    • Rajamaki A. Limits of performance for measurement of blood haemoglobin concentration, number concentration of erythrocytes, and erythrocyte Volume fraction in interlaboratory trials. Results of the Finnish proficiency testing programme in haematology. Scandinavian Journal of Clinical and Laboratry Investigation 1980; 40: 563-6.
    • (1980) Scandinavian Journal of Clinical and Laboratry Investigation , vol.40 , pp. 563-566
    • Rajamaki, A.1
  • 19
    • 0038121577 scopus 로고    scopus 로고
    • Measurement of cerebral oxygenation state in anaesthetized children using the INVOS 5100 cerebral oximeter
    • Dullenkopf A, Frey B, Baenziger O, Gerber A, Weiss M. Measurement of cerebral oxygenation state in anaesthetized children using the INVOS 5100 cerebral oximeter. Paediatric Anaesthesia 2003; 13: 384-91.
    • (2003) Paediatric Anaesthesia , vol.13 , pp. 384-391
    • Dullenkopf, A.1    Frey, B.2    Baenziger, O.3    Gerber, A.4    Weiss, M.5
  • 20
    • 0033988527 scopus 로고    scopus 로고
    • Behaviour of near-infrared light in the adult human head: Implications for clinical near-infrared spectroscopy
    • Young AE, Germon TJ, Barnett NJ, Manara AR, Nelson RJ. Behaviour of near-infrared light in the adult human head: implications for clinical near-infrared spectroscopy. British Journal of Anaesthesia 2000; 84: 38-42.
    • (2000) British Journal of Anaesthesia , vol.84 , pp. 38-42
    • Young, A.E.1    Germon, T.J.2    Barnett, N.J.3    Manara, A.R.4    Nelson, R.J.5
  • 24
    • 0036252605 scopus 로고    scopus 로고
    • Effect of hemolysis on oxygen and hematocrit measurements by near infrared reflectance spectroscopy
    • Neudel F, Takatani S, Reul H, Rau G. Effect of hemolysis on oxygen and hematocrit measurements by near infrared reflectance spectroscopy. Medical Engineering and Physics 2002; 24: 301-7.
    • (2002) Medical Engineering and Physics , vol.24 , pp. 301-307
    • Neudel, F.1    Takatani, S.2    Reul, H.3    Rau, G.4
  • 25
    • 0031160607 scopus 로고    scopus 로고
    • Crit Line: Instrument to aid fluid removal during hemodialysis
    • Sego S. Crit Line: instrument to aid fluid removal during hemodialysis. AANA Journal 1997; 24: 347-8.
    • (1997) AANA Journal , vol.24 , pp. 347-348
    • Sego, S.1
  • 26
    • 0032409967 scopus 로고    scopus 로고
    • Continuous monitoring of hematocrit values during apheresis for allogeneic peripheral blood stem cell collection
    • Kajiume T, Kawano Y, Takaue Y, et al. Continuous monitoring of hematocrit values during apheresis for allogeneic peripheral blood stem cell collection. Journal of Hematotherapy 1998; 7: 493-7.
    • (1998) Journal of Hematotherapy , vol.7 , pp. 493-497
    • Kajiume, T.1    Kawano, Y.2    Takaue, Y.3
  • 28
    • 0036525876 scopus 로고    scopus 로고
    • Comparison of three methods to measure absolute cerebral hemoglobin concentration in neonates by near-infrared spectrophotometry
    • Wolf M, von Siebenthal K, Keel M, et al. Comparison of three methods to measure absolute cerebral hemoglobin concentration in neonates by near-infrared spectrophotometry. Journal of Biomedical Optics 2002; 7: 221-7.
    • (2002) Journal of Biomedical Optics , vol.7 , pp. 221-227
    • Wolf, M.1    von Siebenthal, K.2    Keel, M.3