메뉴 건너뛰기




Volumn 4, Issue 1, 2004, Pages 57-64

Optimization of Endoluminal Loop Radiofrequency Coils For Gastrointestinal Wall MR Imaging

Author keywords

Endoluminal; Gastrointestinal wall; Magnetic resonance imaging (MRI); Radio frequency (RF) coils

Indexed keywords

APPROXIMATION THEORY; CATHETERS; COMPUTER SIMULATION; CURRENT DENSITY; DIAGNOSIS; ELECTRIC RESISTANCE; FINITE ELEMENT METHOD; IMAGE QUALITY; MAGNETIC FIELD EFFECTS; MAXWELL EQUATIONS; NUCLEAR MAGNETIC RESONANCE; OPTIMIZATION; RADIOLOGY; SIGNAL TO NOISE RATIO;

EID: 2342588631     PISSN: 1530437X     EISSN: None     Source Type: Journal    
DOI: 10.1109/JSEN.2003.820334     Document Type: Article
Times cited : (16)

References (28)
  • 1
    • 0034049096 scopus 로고    scopus 로고
    • Magnetic resonance imaging in gastroenterology: Time to say good-bye to all that endoscopy?
    • H. E. Adamek, H. Breer, T. Karschkes, J. Albert, and J. F. Riemann, "Magnetic resonance imaging in gastroenterology: Time to say good-bye to all that endoscopy?," Endoscopy, vol. 32, pp. 406-410, 2000.
    • (2000) Endoscopy , vol.32 , pp. 406-410
    • Adamek, H.E.1    Breer, H.2    Karschkes, T.3    Albert, J.4    Riemann, J.F.5
  • 2
    • 0033861652 scopus 로고    scopus 로고
    • Colon diseases: MR evaluation using combined T2-weighted single-shot echo train spin-echo and gadolinium-enhanced spoiled gradient-echo sequences
    • J. J. Chung, R. C. Semelka, D. R. Martin, and H. B. Marcos, "Colon diseases: MR evaluation using combined T2-weighted single-shot echo train spin-echo and gadolinium-enhanced spoiled gradient-echo sequences," J. Magn. Reson. Imag., vol. 12, pp. 297-305, 2000.
    • (2000) J. Magn. Reson. Imag. , vol.12 , pp. 297-305
    • Chung, J.J.1    Semelka, R.C.2    Martin, D.R.3    Marcos, H.B.4
  • 4
    • 0030014534 scopus 로고    scopus 로고
    • Fistula in ano: Endoanal sonography versus endoanal MR imaging in classification
    • S. M. Hussain, J. Stoker, W. R. Schouten, W. C. Hop, and J. S. Lameris, "Fistula in ano: Endoanal sonography versus endoanal MR imaging in classification," Radiology, vol. 200, pp. 475-481, 1996.
    • (1996) Radiology , vol.200 , pp. 475-481
    • Hussain, S.M.1    Stoker, J.2    Schouten, W.R.3    Hop, W.C.4    Lameris, J.S.5
  • 5
    • 0032957452 scopus 로고    scopus 로고
    • Endoluminal MR imaging of anorectal diseases
    • J. Stoker and E. Rociu, "Endoluminal MR imaging of anorectal diseases," J. Magn. Reson. Imag., vol. 9, pp. 631-634, 1999.
    • (1999) J. Magn. Reson. Imag. , vol.9 , pp. 631-634
    • Stoker, J.1    Rociu, E.2
  • 8
    • 0031023708 scopus 로고    scopus 로고
    • Intravascular magnetic resonance imaging using a loopless catheter antenna
    • O. Ocali and E. Atalar, "Intravascular magnetic resonance imaging using a loopless catheter antenna," Magn. Reson. Med., vol. 37, pp. 112-118, 1997.
    • (1997) Magn. Reson. Med. , vol.37 , pp. 112-118
    • Ocali, O.1    Atalar, E.2
  • 10
    • 0033818666 scopus 로고    scopus 로고
    • Toward MRI-guided coronary catheterization: Visualization of guiding catheters, guidewires, and anatomy in real time
    • J.-M. Serfaty, X. Yang, P. Aksit, H. H. Quick, M. Solaiyappan, and E. Atalar, "Toward MRI-guided coronary catheterization: Visualization of guiding catheters, guidewires, and anatomy in real time," J. Magn. Reson. Imag., vol. 12, pp. 590-594, 2000.
    • (2000) J. Magn. Reson. Imag. , vol.12 , pp. 590-594
    • Serfaty, J.-M.1    Yang, X.2    Aksit, P.3    Quick, H.H.4    Solaiyappan, M.5    Atalar, E.6
  • 17
    • 2342523715 scopus 로고    scopus 로고
    • Optimization of RF solenoidal NMR microcoils performances by electromagnetic simulations
    • MAGMA, Paris, France, Sept. 14-17
    • M. Armenean, H. Saint-Jalmes, and A. Briguet, "Optimization of RF solenoidal NMR microcoils performances by electromagnetic simulations," in ESMAMB, vol. 11, MAGMA, Paris, France, Sept. 14-17, 2000, p. 162.
    • (2000) ESMAMB , vol.11 , pp. 162
    • Armenean, M.1    Saint-Jalmes, H.2    Briguet, A.3
  • 18
    • 0035305997 scopus 로고    scopus 로고
    • Design and testing of high sensitivity microreceiver coil apparatus for nuclear magnetic resonance and imaging
    • D. A. Seeber, R. L. Cooper, L. Ciobanu, and C. H. Pennington, "Design and testing of high sensitivity microreceiver coil apparatus for nuclear magnetic resonance and imaging," Rev. Sci. Instrum., vol. 72, pp. 2171-2179, 2001.
    • (2001) Rev. Sci. Instrum. , vol.72 , pp. 2171-2179
    • Seeber, D.A.1    Cooper, R.L.2    Ciobanu, L.3    Pennington, C.H.4
  • 20
    • 49549133678 scopus 로고
    • The signal-to-noise ratio of the nuclear magnetic resonance experiment
    • D. I. Hoult and R. E. Richards, "The signal-to-noise ratio of the nuclear magnetic resonance experiment," J. Magn. Reson., vol. 24, pp. 71-85, 1976.
    • (1976) J. Magn. Reson. , vol.24 , pp. 71-85
    • Hoult, D.I.1    Richards, R.E.2
  • 21
    • 0026534199 scopus 로고
    • Intravascular (catheter) NMR receiver probe: Preliminary design analysis and applications to canine iliofemoral imaging
    • G. C. Hurst, J. Hua, J. L. Duerk, and A. M. Cohen, "Intravascular (catheter) NMR receiver probe: Preliminary design analysis and applications to canine iliofemoral imaging," Magn. Reson. Med., vol. 24, pp. 343-357, 1992.
    • (1992) Magn. Reson. Med. , vol.24 , pp. 343-357
    • Hurst, G.C.1    Hua, J.2    Duerk, J.L.3    Cohen, A.M.4
  • 22
    • 0027980240 scopus 로고
    • NMR microspectroscopy using 100 μm planar RF coils fabricated on gallium arsenide substrates
    • May
    • T. L. Peck, R. L. Magin, J. Kruse, and M. Feng, "NMR microspectroscopy using 100 μm planar RF coils fabricated on gallium arsenide substrates," IEEE Trans. Biomed. Eng.,Vol. 41, pp. 706-709, May 1994.
    • (1994) IEEE Trans. Biomed. Eng. , vol.41 , pp. 706-709
    • Peck, T.L.1    Magin, R.L.2    Kruse, J.3    Feng, M.4
  • 23
    • 0343384176 scopus 로고    scopus 로고
    • In vivo MR micro imaging with conventional radiofrequency coils cooled to77 K
    • A. C. Wright, H. K. Song, and F. W. Wehrli, "In vivo MR micro imaging with conventional radiofrequency coils cooled to77 K," Magn. Reson. Med., vol. 43, pp. 163-169, 2000.
    • (2000) Magn. Reson. Med. , vol.43 , pp. 163-169
    • Wright, A.C.1    Song, H.K.2    Wehrli, F.W.3
  • 24
    • 0031191460 scopus 로고    scopus 로고
    • Radiofrequency microcoils in magnetic resonance
    • A. G. Webb, "Radiofrequency microcoils in magnetic resonance," Progr. NMR Spectroscopy, vol. 31, pp. 1-42, 1997.
    • (1997) Progr. NMR Spectroscopy , vol.31 , pp. 1-42
    • Webb, A.G.1
  • 25
    • 0029355413 scopus 로고
    • Design and analysis of microcoils for NMR microscopy
    • T. L. Peck, R. L. Magin, and P. C. Lauterbur, "Design and analysis of microcoils for NMR microscopy," J. Magn. Reson. Ser. B, vol. 108, pp. 114-124, 1995.
    • (1995) J. Magn. Reson. Ser. B , vol.108 , pp. 114-124
    • Peck, T.L.1    Magin, R.L.2    Lauterbur, P.C.3
  • 27
    • 0000132799 scopus 로고
    • The sensitivity of the zeugmatography experiment involving human samples
    • D. I. Hoult and P. C. Lauterbur, "The sensitivity of the zeugmatography experiment involving human samples," J. Magn. Reson., vol. 34, pp. 425-433, 1979.
    • (1979) J. Magn. Reson. , vol.34 , pp. 425-433
    • Hoult, D.I.1    Lauterbur, P.C.2
  • 28
    • 0022530353 scopus 로고
    • Surface coil proton MR imaging at 2 T
    • P. Röschmann and R. Tischler, "Surface coil proton MR imaging at 2 T," Radiology, vol. 161, pp. 251-255, 1986.
    • (1986) Radiology , vol.161 , pp. 251-255
    • Röschmann, P.1    Tischler, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.