Indexed keywords
ARTICLE;
BIOMECHANICS;
COMPRESSIVE STRENGTH;
EDENTULOUSNESS;
HUMAN;
IMPLANT;
MANDIBLE;
MAXILLA;
PRACTICE GUIDELINE;
PROTECTION;
TENSILE STRENGTH;
TOOTH IMPLANTATION;
TREATMENT FAILURE;
CASE REPORT;
DENTAL SURGERY;
DENTURE;
MECHANICAL STRESS;
ORTHODONTICS;
SURFACE PROPERTY;
TOOTH OCCLUSION;
TOOTH PROSTHESIS;
TOOTH RADIOGRAPHY;
BIOMECHANICS;
CENTRIC RELATION;
DENTAL IMPLANTS;
DENTAL OCCLUSION, BALANCED;
DENTAL PROSTHESIS, IMPLANT-SUPPORTED;
DENTAL RESTORATION FAILURE;
DENTURE DESIGN;
DENTURE, PARTIAL;
DENTURE, PARTIAL, FIXED;
DENTURE, PARTIAL, TEMPORARY;
HUMANS;
JAW RELATION RECORD;
JAW, EDENTULOUS;
MANDIBLE;
MAXILLA;
OCCLUSAL ADJUSTMENT;
STRESS, MECHANICAL;
SURFACE PROPERTIES;
VERTICAL DIMENSION;
1
0346276532
Clinical biomechanics in implant dentistry
Misch CE, ed. St. Louis: Mosby
Misch CE. Clinical biomechanics in implant dentistry. In: Misch CE, ed. Contemporary Implant Dentistry, 2nd ed. St. Louis: Mosby; 1999:303-316.
(1999)
Contemporary Implant Dentistry, 2nd Ed.
, pp. 303-316
Misch, C.E.1
2
0032233253
Reduction of implant loading with therapeutic biomechanics
Weinberg LA. Reduction of implant loading with therapeutic biomechanics. Implant Dentistry. 1998;7:277-285.
(1998)
Implant Dentistry
, vol.7
, pp. 277-285
Weinberg, L.A.1
3
0019663098
A 15-year study of osseointegrated implants in the treatment of the edentulous jaw
Adell R, Lekholm B, Rockler B, et al. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Maxillofac Surg. 1981;10: 387-396.
(1981)
Int J Oral Maxillofac Surg
, vol.10
, pp. 387-396
Adell, R.1
Lekholm, B.2
Rockler, B.3
5
0027355488
Treatment planning and placement of implants in the posterior maxillae: Report of 732 consecutive Nobelpharma implants
Bahat O. Treatment planning and placement of implants in the posterior maxillae: Report of 732 consecutive Nobelpharma implants. Int J Oral Maxillofac Implants. 1993;8:151-157.
(1993)
Int J Oral Maxillofac Implants
, vol.8
, pp. 151-157
Bahat, O.1
6
14844285097
Chapter 10. Diagnostic casts, preimplant prosthodontics, treatment prostheses, and surgical templates
Misch CE, ed. St. Louis: Mosby
Misch CE. Chapter 10. Diagnostic casts, preimplant prosthodontics, treatment prostheses, and surgical templates In: Misch CE, ed. Contemporary Implant Dentistry, 2nd ed. St. Louis: Mosby; 1999: 140-141.
(1999)
Contemporary Implant Dentistry, 2nd Ed.
, pp. 140-141
Misch, C.E.1
7
0036048370
Rehabilitation of the edentulous maxilla and mandible with fixed implant-supported restorations applying immediate functional loading: A treatment concept
Bocklage R. Rehabilitation of the edentulous maxilla and mandible with fixed implant-supported restorations applying immediate functional loading: A treatment concept. Implant Dentistry. 2002;11:154-158.
(2002)
Implant Dentistry
, vol.11
, pp. 154-158
Bocklage, R.1
8
0347225514
The geometries of the gnathic system
Stuart CE. The geometries of the gnathic system. J Gnathol. 1982;1:6-13.
(1982)
J Gnathol
, vol.1
, pp. 6-13
Stuart, C.E.1
9
0015445397
Centric relation recording techniques: A comparative investigation
Kantor M, Silverman S, Garfinkel L. Centric relation recording techniques: A comparative investigation. J Prosthet Dent. 1972;28:593-600.
(1972)
J Prosthet Dent
, vol.28
, pp. 593-600
Kantor, M.1
Silverman, S.2
Garfinkel, L.3
10
1842587273
Axial inclination and cuspal articulation in relation to force distribution
Weinberg LA. Axial inclination and cuspal articulation in relation to force distribution. J Prosthet Dent. 1957;7:804-813.
(1957)
J Prosthet Dent
, vol.7
, pp. 804-813
Weinberg, L.A.1
11
0035228562
Advanced alveolar crest atrophy: An alternative treatment technique for maxilla and mandible
Bocklage R. Advanced alveolar crest atrophy: An alternative treatment technique for maxilla and mandible. Implant Dentistry. 2001;10:30-35.
(2001)
Implant Dentistry
, vol.10
, pp. 30-35
Bocklage, R.1
12
0031136510
Immediate loading of threaded implants at one stage surgery in edentulous arches: Ten consecutive case reports with 1 to 5 year data
Tarnow DP, Emitiag S, Classi A. Immediate loading of threaded implants at one stage surgery in edentulous arches: Ten consecutive case reports with 1 to 5 year data. Int J Oral Maxillofac Implants. 1997;12:319-324.
(1997)
Int J Oral Maxillofac Implants
, vol.12
, pp. 319-324
Tarnow, D.P.1
Emitiag, S.2
Classi, A.3
13
0347855676
Overlap of the upper anterior teeth and its determinants
Stuart CE. Overlap of the upper anterior teeth and its determinants. J Gnathol. 1983;2:3-10.
(1983)
J Gnathol
, vol.2
, pp. 3-10
Stuart, C.E.1
14
0012370346
Bone response to mechanical loads
Misch CE, ed. St. Louis: Mosby
Misch CE. Bone response to mechanical loads. In: Misch CE, ed. Contemporary Implant Dentistry, 2nd ed. St. Louis: Mosby; 1999:317-328.
(1999)
Contemporary Implant Dentistry, 2nd Ed.
, pp. 317-328
Misch, C.E.1
15
0027437139
Structure of the bone interface to dental implants in vivo
De Lange G, De Putter C. Structure of the bone interface to dental implants in vivo. J Oral Implantol. 1993;19:123-135.
(1993)
J Oral Implantol
, vol.19
, pp. 123-135
De Lange, G.1
De Putter, C.2
17
0030339776
A study of maximum bite force during growth and development
Braun S, Hnat WP, Freudenthaler JW, et al. A study of maximum bite force during growth and development. Angle Orthodont. 1996;66:261-264.
(1996)
Angle Orthodont
, vol.66
, pp. 261-264
Braun, S.1
Hnat, W.P.2
Freudenthaler, J.W.3