메뉴 건너뛰기




Volumn 50, Issue 3, 2004, Pages 285-290

A Temporal and Spatial Analysis of Cavitation on Mechanical Heart Valves by Observing Faint Light Emission

Author keywords

[No Author keywords available]

Indexed keywords

BUBBLES (IN FLUIDS); LIGHT EMISSION; OPTICAL FIBERS; ORIFICES; PHOTONS;

EID: 2342548651     PISSN: 10582916     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.MAT.0000123687.91183.21     Document Type: Article
Times cited : (5)

References (20)
  • 2
    • 0028223502 scopus 로고
    • Cavitation threshold ranking and erosion characteristics of bileaflet heart valve prostheses
    • Richard G, Beavan A, Strzepa P: Cavitation threshold ranking and erosion characteristics of bileaflet heart valve prostheses. J Heart Valve Dis 3 (Suppl. 1): S94-S101, 1994.
    • (1994) J Heart Valve Dis , vol.3 , Issue.SUPPL. 1
    • Richard, G.1    Beavan, A.2    Strzepa, P.3
  • 4
    • 0003817721 scopus 로고    scopus 로고
    • Imperial College Press, London
    • Young FR: Cavitation. Imperial College Press, London, 1999.
    • (1999) Cavitation
    • Young, F.R.1
  • 7
    • 0027379235 scopus 로고
    • Relative blood damage in the three phases of a prosthetic heart valve flow cycle
    • Lamson TC, Rosenberg G, Geselowitz DB, et al: Relative blood damage in the three phases of a prosthetic heart valve flow cycle. ASAIO J 39: M626-M633, 1993.
    • (1993) ASAIO J , vol.39
    • Lamson, T.C.1    Rosenberg, G.2    Geselowitz, D.B.3
  • 8
    • 0028533615 scopus 로고
    • A method for real-time in vitro observation of cavitation on prosthetic heart valves
    • Zapanta CM, Liszka EG, Lamson TC, et al: A method for real-time in vitro observation of cavitation on prosthetic heart valves. J Biomechanic Eng 116: 460-468, 1994.
    • (1994) J Biomechanic Eng , vol.116 , pp. 460-468
    • Zapanta, C.M.1    Liszka, E.G.2    Lamson, T.C.3
  • 9
    • 0030442881 scopus 로고    scopus 로고
    • A review of in vitro bioeffects of inertial ultrasonic cavitation from a mechanistic perspective
    • Miller MW, Miller DL, Brayman AA: A review of in vitro bioeffects of inertial ultrasonic cavitation from a mechanistic perspective. Ultrasound Med Biol 22: 1131-1154, 1996.
    • (1996) Ultrasound Med Biol , vol.22 , pp. 1131-1154
    • Miller, M.W.1    Miller, D.L.2    Brayman, A.A.3
  • 10
    • 0037902592 scopus 로고
    • Sonochemistry
    • Suslick KS: Sonochemistry. Science 247: 1439-1445, 1990.
    • (1990) Science , vol.247 , pp. 1439-1445
    • Suslick, K.S.1
  • 11
    • 10244229686 scopus 로고    scopus 로고
    • In vivo observation of cavitation on prosthetic heart valves
    • Zapanta CM, Stinebring DR, Sneckenberger DS, et al: In vivo observation of cavitation on prosthetic heart valves. ASAIO J 42: M550-M555, 1996.
    • (1996) ASAIO J , vol.42
    • Zapanta, C.M.1    Stinebring, D.R.2    Sneckenberger, D.S.3
  • 12
    • 0030250463 scopus 로고    scopus 로고
    • Transient pressure signal in mechanical heart valve cavitation
    • Wu ZJ, Slonin JH, Hwang NHC: Transient pressure signal in mechanical heart valve cavitation. ASAIO J 42: M555-M561, 1996.
    • (1996) ASAIO J , vol.42
    • Wu, Z.J.1    Slonin, J.H.2    Hwang, N.H.C.3
  • 13
    • 0031733109 scopus 로고    scopus 로고
    • A comparison of the cavitation potential of prosthetic heart valves based on valve closing dynamics
    • Zapanta CM, Stinebring DR, Deutsch S, Geselowitz DB, Tarbell JM: A comparison of the cavitation potential of prosthetic heart valves based on valve closing dynamics. J Heart Valve Dis 7: 655-667, 1998.
    • (1998) J Heart Valve Dis , vol.7 , pp. 655-667
    • Zapanta, C.M.1    Stinebring, D.R.2    Deutsch, S.3    Geselowitz, D.B.4    Tarbell, J.M.5
  • 15
    • 0028216521 scopus 로고
    • Causes and formation of cavitation in mechanical heart valves
    • Graf T, Reul H, Detlefs C, Wilmes R, Rau G: Causes and formation of cavitation in mechanical heart valves. J Heart Valve Dis 3 (Suppl. 1): S49-S64, 1994.
    • (1994) J Heart Valve Dis , vol.3 , Issue.SUPPL. 1
    • Graf, T.1    Reul, H.2    Detlefs, C.3    Wilmes, R.4    Rau, G.5
  • 16
    • 2342597847 scopus 로고    scopus 로고
    • Acoustic technique to detect cavitation near prosthetic heart valves
    • US FDA, CDRH: Acoustic technique to detect cavitation near prosthetic heart valves. OST Annual Report 1997. Available at: http://www.fda.gov/cdrh/ost/rpt97/OST1997AR69.html.
    • (1997) OST Annual Report
  • 17
    • 0035395868 scopus 로고    scopus 로고
    • Effect of liquid temperature on sonoluminescence
    • 10 pages
    • Yasui K: Effect of liquid temperature on sonoluminescence. Phys Rev E 64: 016310 (10 pages), 2001.
    • (2001) Phys Rev E , vol.64 , pp. 016310
    • Yasui, K.1
  • 19
    • 0024023693 scopus 로고
    • Cavitation threshold measurements for microsecond length pulses of ultrasound
    • Fowlkes JB, Crum LA: Cavitation threshold measurements for microsecond length pulses of ultrasound. J Acoust Soc Am 83: 2190-2201, 1988.
    • (1988) J Acoust Soc Am , vol.83 , pp. 2190-2201
    • Fowlkes, J.B.1    Crum, L.A.2
  • 20
    • 0037542569 scopus 로고    scopus 로고
    • A new approach to detection of the cavitation on mechanical heart valves
    • Takirua K, Chinzei T, Abe Y, et al: A new approach to detection of the cavitation on mechanical heart valves. ASAIO J 49: 304-308, 2003.
    • (2003) ASAIO J , vol.49 , pp. 304-308
    • Takirua, K.1    Chinzei, T.2    Abe, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.