메뉴 건너뛰기




Volumn 93, Issue 10, 2004, Pages 1318-1319

Validation of the i-STAT handheld activated clotting time for use with bivalirudin

Author keywords

[No Author keywords available]

Indexed keywords

ANTICOAGULANT AGENT; HIRULOG; THROMBIN;

EID: 2342534949     PISSN: 00029149     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.amjcard.2004.01.076     Document Type: Article
Times cited : (11)

References (12)
  • 1
    • 0037441726 scopus 로고    scopus 로고
    • Comparison of the i-STAT handheld activated clotting time with the Hemochron activated clotting time during and after percutaneous coronary intervention
    • Schussler J.M., Aguanno J.J., Glover E.N., Vish N.A., Wissinger L.A., Schumacher J.R., Wheelan K.R. Comparison of the i-STAT handheld activated clotting time with the Hemochron activated clotting time during and after percutaneous coronary intervention. Am J Cardiol. 91:2003;464-466
    • (2003) Am J Cardiol , vol.91 , pp. 464-466
    • Schussler, J.M.1    Aguanno, J.J.2    Glover, E.N.3    Vish, N.A.4    Wissinger, L.A.5    Schumacher, J.R.6    Wheelan, K.R.7
  • 2
    • 0035889428 scopus 로고    scopus 로고
    • Planning a reproducibility study: How many subjects and how many replicates per subject for an expected width of the 95 per cent confidence interval of the intraclass correlation coefficient
    • Giraudeau B., Mary J.Y. Planning a reproducibility study how many subjects and how many replicates per subject for an expected width of the 95 per cent confidence interval of the intraclass correlation coefficient. Stat Med. 20:2001;3205-3214
    • (2001) Stat Med , vol.20 , pp. 3205-3214
    • Giraudeau, B.1    Mary, J.Y.2
  • 3
    • 0037093925 scopus 로고    scopus 로고
    • Sample size requirements for estimating intraclass correlations with desired precision
    • Bonett D.G. Sample size requirements for estimating intraclass correlations with desired precision. Stat Med. 21:2002;1331-1335
    • (2002) Stat Med , vol.21 , pp. 1331-1335
    • Bonett, D.G.1
  • 4
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis J.R., Koch G.G. The measurement of observer agreement for categorical data. Biometrics. 33:1977;159-174
    • (1977) Biometrics , vol.33 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 5
    • 0024496264 scopus 로고
    • Statistical evaluation of agreement between two methods for measuring a quantitative variable
    • Lee J.K., D Ong C.N. Statistical evaluation of agreement between two methods for measuring a quantitative variable. Comput Biol Med. 19:1989;61-70
    • (1989) Comput Biol Med , vol.19 , pp. 61-70
    • Lee, J.K.1    Ong C N, D.2
  • 6
    • 0037453968 scopus 로고    scopus 로고
    • Bivalirudin and provisional glycoprotein IIb/IIIa blockade compared with heparin and planned glycoprotein IIb/IIIa blockade during percutaneous coronary intervention: REPLACE-2 randomized trial
    • Lincoff A.M., Bittl J.A., Harrington R.A., Feit F., Kleiman N.S., Jackman J.D., Sarembock I.J., Cohen D.J., Spriggs D., Ebrahimi R., et al. Bivalirudin and provisional glycoprotein IIb/IIIa blockade compared with heparin and planned glycoprotein IIb/IIIa blockade during percutaneous coronary intervention REPLACE-2 randomized trial. JAMA. 289:2003;853-863
    • (2003) JAMA , vol.289 , pp. 853-863
    • Lincoff, A.M.1    Bittl, J.A.2    Harrington, R.A.3    Feit, F.4    Kleiman, N.S.5    Jackman, J.D.6    Sarembock, I.J.7    Cohen, D.J.8    Spriggs, D.9    Ebrahimi, R.10
  • 7
    • 2342649499 scopus 로고    scopus 로고
    • Bivalirudin in the cath lab: A recovery area time analysis. Oral and poster presentations
    • Schussler J.M., Lander S.R., Johnson K.B., Vallabhan R.C. Bivalirudin in the cath lab a recovery area time analysis. Oral and poster presentations. Catheter Cardiovasc Interv. 59:2003;121-142
    • (2003) Catheter Cardiovasc Interv , vol.59 , pp. 121-142
    • Schussler, J.M.1    Lander, S.R.2    Johnson, K.B.3    Vallabhan, R.C.4
  • 8
    • 0027410804 scopus 로고
    • Evaluation of a novel point-of-care system, the i-STAT portable clinical analyzer
    • Erickson K.A., Wilding P. Evaluation of a novel point-of-care system, the i-STAT portable clinical analyzer. Clin Chem. 39:1993;283-287
    • (1993) Clin Chem , vol.39 , pp. 283-287
    • Erickson, K.A.1    Wilding, P.2
  • 9
    • 0027427244 scopus 로고
    • I-STAT point-of-care blood analyzing system
    • Kisner H.J. i-STAT point-of-care blood analyzing system. Clin Lab Manag Rev. 7:1993;454-457
    • (1993) Clin Lab Manag Rev , vol.7 , pp. 454-457
    • Kisner, H.J.1
  • 10
    • 0032917896 scopus 로고    scopus 로고
    • The portable laboratory: An evaluation of the accuracy and reproducibility of i-STAT
    • Bingham D., Kendall J., Clancy M. The portable laboratory an evaluation of the accuracy and reproducibility of i-STAT. Ann Clin Biochem. 36:1999;66-71
    • (1999) Ann Clin Biochem , vol.36 , pp. 66-71
    • Bingham, D.1    Kendall, J.2    Clancy, M.3
  • 11
    • 0034959514 scopus 로고    scopus 로고
    • Evaluation of i-STAT creatinine assay
    • Gault M.H., Seymour M.E., Howell W.E. Evaluation of i-STAT creatinine assay. Nephron. 88:2001;178-182
    • (2001) Nephron , vol.88 , pp. 178-182
    • Gault, M.H.1    Seymour, M.E.2    Howell, W.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.