메뉴 건너뛰기




Volumn 25, Issue 2, 2004, Pages 421-436

A new biomedical sensor for measuring PCO2

Author keywords

Biomedical sensor; Conductivity; Gas measuring; Ischemia; PCO2

Indexed keywords

BRIDGES; CARBON DIOXIDE; GAS PERMEABLE MEMBRANES; SOLUTIONS;

EID: 2342475162     PISSN: 09673334     EISSN: None     Source Type: Journal    
DOI: 10.1088/0967-3334/25/2/002     Document Type: Article
Times cited : (18)

References (30)
  • 6
    • 0032198157 scopus 로고    scopus 로고
    • Microtechnology in modern health care
    • Detemple P et al 1998 Microtechnology in modern health care Med. Device Technol. 11 18
    • (1998) Med. Device Technol. , vol.11 , pp. 18
    • Detemple, P.1
  • 7
    • 0024572263 scopus 로고
    • Dielectric properties of tissue and biological materials: A critical review
    • Foster K R and Schwan H P 1989 Dielectric properties of tissue and biological materials: a critical review CRC Crit. Rev. Biomed. Eng. 17 25-104
    • (1989) CRC Crit. Rev. Biomed. Eng. , vol.17 , pp. 25-104
    • Foster, K.R.1    Schwan, H.P.2
  • 11
    • 0032976072 scopus 로고    scopus 로고
    • Measurement of ischemia by changes in tissue oxygen, carbon dioxide and pH
    • Hoffman W E et al 1998 Measurement of ischemia by changes in tissue oxygen, carbon dioxide and pH Surg. Neurol. 51 654-8
    • (1998) Surg. Neurol. , vol.51 , pp. 654-658
    • Hoffman, W.E.1
  • 12
    • 2342649655 scopus 로고    scopus 로고
    • Experimental study of arteriovenous differences in pH and partial pressure of carbon dioxide as indicators of tissue hypoxia
    • Hong X J 1996 Experimental study of arteriovenous differences in pH and partial pressure of carbon dioxide as indicators of tissue hypoxia Blood Gas News 5 3-9
    • (1996) Blood Gas News , vol.5 , pp. 3-9
    • Hong, X.J.1
  • 13
    • 0028971121 scopus 로고
    • Design optimisation of planar electrolytic conductivity sensors
    • Jacobs P, Varlan A R and Sansen W 1995 Design optimisation of planar electrolytic conductivity sensors Med. Biol. Eng. Comput. 33 802-10
    • (1995) Med. Biol. Eng. Comput. , vol.33 , pp. 802-810
    • Jacobs, P.1    Varlan, A.R.2    Sansen, W.3
  • 17
    • 0018512753 scopus 로고
    • A pCO2 surface electrode working on the principle of electrical conductivity
    • Lis K et al 1979 A pCO2 surface electrode working on the principle of electrical conductivity Pflugers Arch. 381 289-91
    • (1979) Pflugers Arch. , vol.381 , pp. 289-291
    • Lis, K.1
  • 18
    • 0002881647 scopus 로고    scopus 로고
    • Miniaturized plastic micro plates for applications in HTS
    • Niggermann M, Ehrfeld W and Weber L 1999 Miniaturized plastic micro plates for applications in HTS Microsyst. Technol. 6 48-53
    • (1999) Microsyst. Technol. , vol.6 , pp. 48-53
    • Niggermann, M.1    Ehrfeld, W.2    Weber, L.3
  • 20
    • 0020137662 scopus 로고
    • Linear and nonlinear properties of platinum electrode polarization: Part 1. Frequency dependence at very low frequencies
    • Onaral B and Schwan H P 1982 Linear and nonlinear properties of platinum electrode polarization: Part 1. Frequency dependence at very low frequencies Med. Biol. Eng. Comput. 20 229-306
    • (1982) Med. Biol. Eng. Comput. , vol.20 , pp. 229-306
    • Onaral, B.1    Schwan, H.P.2
  • 21
    • 0025405495 scopus 로고
    • Electrical properties of the metallic electrodes
    • Ragheb T and Geddes L A 1990 Electrical properties of the metallic electrodes Med. Biol. Eng. Comput. 28 182-6
    • (1990) Med. Biol. Eng. Comput. , vol.28 , pp. 182-186
    • Ragheb, T.1    Geddes, L.A.2
  • 22
    • 84995189684 scopus 로고
    • Experience with invasive and non-invasive sensors for anaesthesia
    • Rolfe P 1995 Experience with invasive and non-invasive sensors for anaesthesia Acta Anaesthesiol. Scand. 104 61-8
    • (1995) Acta Anaesthesiol. Scand. , vol.104 , pp. 61-68
    • Rolfe, P.1
  • 23
    • 0014254029 scopus 로고
    • Electrode polarization impedance and measurements in biological materials
    • Schwan H 1968 Electrode polarization impedance and measurements in biological materials Ann. New York Acad. Sci. 148 191-209
    • (1968) Ann. New York Acad. Sci. , vol.148 , pp. 191-209
    • Schwan, H.1
  • 24
    • 0000477840 scopus 로고
    • Four-electrode null technique for impedance measurements with high resolution
    • Schwan H P and Ferris C D 1963 Four-electrode null technique for impedance measurements with high resolution Rev. Sci. Instrum. 39 481-3
    • (1963) Rev. Sci. Instrum. , vol.39 , pp. 481-483
    • Schwan, H.P.1    Ferris, C.D.2
  • 27
    • 0001493816 scopus 로고
    • Rapid measurement of the tension of carbon dioxide in blood
    • Stow R W, Baer R F and Randall B F 1957 Rapid measurement of the tension of carbon dioxide in blood Arch. Phys. Med. Rehabil. 7 646-50
    • (1957) Arch. Phys. Med. Rehabil. , vol.7 , pp. 646-650
    • Stow, R.W.1    Baer, R.F.2    Randall, B.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.