메뉴 건너뛰기




Volumn 29, Issue 9, 2004, Pages 1000-1004

Morphologic Characteristics of Atlantoaxial Complex in Rheumatoid Arthritis and Surgical Consideration among Chinese

Author keywords

Atlantoaxial subluxation; Chinese; Morphology; Rheumatoid arthritis

Indexed keywords

ADULT; AGED; ANATOMICAL VARIATION; ARTHRODESIS; ARTICLE; ATLANTOAXIAL JOINT; BONE SCREW; CALCULATION; CERVICAL SPINE; CHINESE; CLINICAL ARTICLE; FEMALE; HUMAN; MALE; MEASUREMENT; MORPHOMETRICS; PRIORITY JOURNAL; RHEUMATOID ARTHRITIS; SPINE TUMOR; SURGICAL ANATOMY; SURGICAL TECHNIQUE;

EID: 2342456426     PISSN: 03622436     EISSN: None     Source Type: Journal    
DOI: 10.1097/00007632-200405010-00009     Document Type: Article
Times cited : (17)

References (22)
  • 1
    • 0023945481 scopus 로고    scopus 로고
    • The American Rheumatism Association 1987 revised criteria for the classification of rheumatoid arthritis
    • Arnett FC, Edworthy SM, Bloch DA, et al. The American Rheumatism Association 1987 revised criteria for the classification of rheumatoid arthritis. Arthritis Rheum. 1998;31:315-324.
    • (1998) Arthritis Rheum , vol.31 , pp. 315-324
    • Arnett, F.C.1    Edworthy, S.M.2    Bloch, D.A.3
  • 2
    • 0004814824 scopus 로고    scopus 로고
    • Rheumatological disorders
    • Menezes AH, Sonntag VKH, eds. New York: McGraw-Hill
    • Menezes AH. Rheumatological disorders. In: Menezes AH, Sonntag VKH, eds. Principles of Spinal Surgery. New York: McGraw-Hill, 1996:705-722.
    • (1996) Principles of Spinal Surgery , pp. 705-722
    • Menezes, A.H.1
  • 3
    • 0032143648 scopus 로고    scopus 로고
    • Anatomic study for ideal and safe posterior C1/C2 transarticular screw fixation
    • Jun BY. Anatomic study for ideal and safe posterior C1/C2 transarticular screw fixation. Spine. 1998;23:1703-1707.
    • (1998) Spine , vol.23 , pp. 1703-1707
    • Jun, B.Y.1
  • 4
    • 0030973318 scopus 로고    scopus 로고
    • Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique
    • Madawi AA, Casey ATH, Solanki GA, et al. Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg. 1997;86:961-968.
    • (1997) J Neurosurg , vol.86 , pp. 961-968
    • Madawi, A.A.1    Casey, A.T.H.2    Solanki, G.A.3
  • 6
    • 0023685365 scopus 로고
    • Role of magnetic resonance imaging and three dimensional computerized tomography in craniovertebral junction anomalies
    • Pappas CTE, Rekate HL. Role of magnetic resonance imaging and three dimensional computerized tomography in craniovertebral junction anomalies. Pediatr Neurosci. 1988;14:18-22.
    • (1988) Pediatr Neurosci , vol.14 , pp. 18-22
    • Pappas, C.T.E.1    Rekate, H.L.2
  • 7
  • 8
    • 0022620526 scopus 로고
    • The spinal cord in rheumatoid arthritis with clinical myelopathy: A computed myelographic study
    • Stevens JM, Kendall BE, Crockard HA. The spinal cord in rheumatoid arthritis with clinical myelopathy: a computed myelographic study. J Neurol Neurosurg Psychiatry. 1986;49:140-151.
    • (1986) J Neurol Neurosurg Psychiatry , vol.49 , pp. 140-151
    • Stevens, J.M.1    Kendall, B.E.2    Crockard, H.A.3
  • 9
    • 0030055004 scopus 로고    scopus 로고
    • Biomechanical characteristics of C1-2 cable fixation
    • Dickman CA, Crawford NR, Paramore CG. Biomechanical characteristics of C1-2 cable fixation. J Neurosurg. 1996;85:316-322.
    • (1996) J Neurosurg , vol.85 , pp. 316-322
    • Dickman, C.A.1    Crawford, N.R.2    Paramore, C.G.3
  • 10
    • 0026694623 scopus 로고
    • Biomechanical evaluation of four different posterior atlantoaxial fixation technique
    • Haid JRW, Grob D, Crisco JJ, et al. Biomechanical evaluation of four different posterior atlantoaxial fixation technique. Spine. 1992;17:480-489.
    • (1992) Spine , vol.17 , pp. 480-489
    • Haid, J.R.W.1    Grob, D.2    Crisco, J.J.3
  • 11
    • 0002257576 scopus 로고
    • Stable posterior fusion of the atlas and axis by transarticular screw fixation
    • Kerh P, Weidner A, eds. Vienna: Springer-Verlag
    • Magerl F, Seeman PS. Stable posterior fusion of the atlas and axis by transarticular screw fixation. In: Kerh P, Weidner A, eds. Cervical Spine, vol. 1. Vienna: Springer-Verlag, 1987:322-327.
    • (1987) Cervical Spine , vol.1 , pp. 322-327
    • Magerl, F.1    Seeman, P.S.2
  • 12
    • 0034866583 scopus 로고    scopus 로고
    • Effect of frameless stereotaxy on the accuracy of C1-2 transarticular screw placement
    • Bloch O, Holly LT, Park J, et al. Effect of frameless stereotaxy on the accuracy of C1-2 transarticular screw placement. J Neurosurg. 2001;95:74-79.
    • (2001) J Neurosurg , vol.95 , pp. 74-79
    • Bloch, O.1    Holly, L.T.2    Park, J.3
  • 13
    • 0030017856 scopus 로고    scopus 로고
    • Arterio-venous fistula as a complication of C1-2 transarticular screw fixation: Case report and review of the literature
    • Coric D, Branch CL, Wilson JA, et al. Arterio-venous fistula as a complication of C1-2 transarticular screw fixation: case report and review of the literature. J Neurosurg. 1996;85:340-343.
    • (1996) J Neurosurg , vol.85 , pp. 340-343
    • Coric, D.1    Branch, C.L.2    Wilson, J.A.3
  • 14
    • 0006919770 scopus 로고    scopus 로고
    • Occipitocervical screw plates
    • Dickman CA, Spetzler RF, eds. New York: Thieme
    • Dickman CA. Occipitocervical screw plates. In: Dickman CA, Spetzler RF, eds. Surgery of the Craniovertebral Junction. New York: Thieme, 1998:761-768.
    • (1998) Surgery of the Craniovertebral Junction , pp. 761-768
    • Dickman, C.A.1
  • 15
    • 0029773340 scopus 로고    scopus 로고
    • The anatomical suitability of the C1-2 complex for transarticular screw fixation
    • Paramore CG, Dickman CA, Sonntag VKH. The anatomical suitability of the C1-2 complex for transarticular screw fixation. J Neurosurg. 1996;85:221-224.
    • (1996) J Neurosurg , vol.85 , pp. 221-224
    • Paramore, C.G.1    Dickman, C.A.2    Sonntag, V.K.H.3
  • 16
    • 0037102598 scopus 로고    scopus 로고
    • Posterior atlantoaxial fixation; Biomechanical in vitro comparison of six different techniques
    • Richter M, Schmidt R, Claes L, et al. Posterior atlantoaxial fixation; Biomechanical in vitro comparison of six different techniques. Spine. 2002;27:1724-1732.
    • (2002) Spine , vol.27 , pp. 1724-1732
    • Richter, M.1    Schmidt, R.2    Claes, L.3
  • 17
    • 1842414315 scopus 로고    scopus 로고
    • Unilateral posterior atlantoaxial transarticular screw fixation
    • Song GS, Theodore N, Dickman CA, et al. Unilateral posterior atlantoaxial transarticular screw fixation. J Neurosurg. 1997;87:851-855.
    • (1997) J Neurosurg , vol.87 , pp. 851-855
    • Song, G.S.1    Theodore, N.2    Dickman, C.A.3
  • 18
    • 0026000310 scopus 로고
    • Complications of fusion to the upper cervical spine
    • Smith MD, Phillips WA, Hensinger RN. Complications of fusion to the upper cervical spine. Spine. 1991;16:702-705.
    • (1991) Spine , vol.16 , pp. 702-705
    • Smith, M.D.1    Phillips, W.A.2    Hensinger, R.N.3
  • 20
    • 0034973263 scopus 로고    scopus 로고
    • C1-C2 transarticular screw fixation for atlantoaxial instability: A 6-year experience
    • Subach BR, McLaughlin MR, Rodts JGE, et al. C1-C2 transarticular screw fixation for atlantoaxial instability: a 6-year experience. Neurosurgery. 2001;49:65-70.
    • (2001) Neurosurgery , vol.49 , pp. 65-70
    • Subach, B.R.1    McLaughlin, M.R.2    Rodts, J.G.E.3
  • 21
    • 2342484304 scopus 로고    scopus 로고
    • Application of transfacet screw fixation in C1 (atlas)-C2 (axis) subluxation by helical CT and workstation [in Chinese]
    • Chang SC, Chen TY, Liao TF, et al. Application of transfacet screw fixation in C1 (atlas)-C2 (axis) subluxation by helical CT and workstation [in Chinese]. J Radiol Tech. 2001;25:9-14.
    • (2001) J Radiol Tech , vol.25 , pp. 9-14
    • Chang, S.C.1    Chen, T.Y.2    Liao, T.F.3
  • 22
    • 0032950211 scopus 로고    scopus 로고
    • Inside-outside technique for posterior occipitocervical spine instrumentation and stabilization: Preliminary results
    • Pait TG, Al-Mefty O, Boop FA, et al. Inside-outside technique for posterior occipitocervical spine instrumentation and stabilization: preliminary results. J Neurosurg. 1999;90:1-7.
    • (1999) J Neurosurg , vol.90 , pp. 1-7
    • Pait, T.G.1    Al-Mefty, O.2    Boop, F.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.