메뉴 건너뛰기




Volumn 24, Issue 2, 2004, Pages 28-32

Principle of transient current grounded relay for feeder in ungrounded distribution systems

Author keywords

Distribution system; Feature band; Orthogonal wavelet analysis; Single phase ground fault protection; Transient current component; Ungrounded neutral mode

Indexed keywords

CALCULATIONS; COMPUTER SIMULATION; COMPUTER SOFTWARE; ELECTRIC FAULT CURRENTS; ELECTRIC POWER SYSTEM PROTECTION; SENSITIVITY ANALYSIS; STABILITY CRITERIA; SYSTEM STABILITY; WAVELET TRANSFORMS;

EID: 2342425128     PISSN: 02588013     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (31)

References (8)
  • 1
    • 0035322407 scopus 로고    scopus 로고
    • Study on feeder grounding fault protection based on zero sequence admittance
    • Zeng Xiangjun, Yin Xianggen, Zhang Zhe, et al. Study on feeder grounding fault protection based on zero sequence admittance [J]. Proceedings of the CSEE, 2001, 21(4): 5-10.
    • (2001) Proceedings of the CSEE , vol.21 , Issue.4 , pp. 5-10
    • Zeng, X.1    Yin, X.2    Zhang, Z.3
  • 2
    • 0035494026 scopus 로고    scopus 로고
    • A new approach on detecting the single-to-ground fault location on power system with neutral unearthed
    • Li Meng-qiu, Wang Yao-nan, Wang Hui, et al. A new approach on detecting the single-to-ground fault location on power system with neutral unearthed [J]. Proceedings of the CSEE, 2001, 21(10): 6-9.
    • (2001) Proceedings of the CSEE , vol.21 , Issue.10 , pp. 6-9
    • Li, M.-Q.1    Wang, Y.-N.2    Wang, H.3
  • 3
    • 0002568628 scopus 로고    scopus 로고
    • Wavelets packet based detection of phase-to-ground fault in distribution automation system
    • Mao Peng, Sun Yaming, Zhang Zhaoning, et al. Wavelets packet based detection of phase-to-ground fault in distribution automation system [J]. Power System Technology, 2000, 24(6): 9-13.
    • (2000) Power System Technology , vol.24 , Issue.6 , pp. 9-13
    • Mao, P.1    Sun, Y.2    Zhang, Z.3
  • 4
    • 0035494105 scopus 로고    scopus 로고
    • Abrupt change detection with wavelet for small current fault relaying
    • Jia Qingquan, Liu Lianguang, Yang Yihan, Abrupt change detection with wavelet for small current fault relaying [J]. Proceedings of the CSEE, 2001, 21(10): 78-82.
    • (2001) Proceedings of the CSEE , vol.21 , Issue.10 , pp. 78-82
    • Jia, Q.1    Liu, L.2    Yang, Y.3
  • 5
    • 0030193361 scopus 로고    scopus 로고
    • Wavelets: A new tool for the resonant grounded power distribution systems relaying
    • Oinis Chaari, Michel Meunier, Francoise Brouaye. Wavelets: A New Tool for the Resonant Grounded Power Distribution Systems Relaying [J]. IEEE Trans. on Power Delivery, 1996, 11(3): 1301-1308.
    • (1996) IEEE Trans. on Power Delivery , vol.11 , Issue.3 , pp. 1301-1308
    • Chaari, O.1    Meunier, M.2    Brouaye, F.3
  • 7
    • 0035419337 scopus 로고    scopus 로고
    • Wavelet transforms in power systems. Part II: Examples of application to actual power system transients
    • Chul Hwan Kim, Raj Aggarwal. Wavelet Transforms in Power Systems: Part II Examples of Application to Actual Power System Transients [J]. Power Engineering Journal, 2001, 15(4): 193-202.
    • (2001) Power Engineering Journal , vol.15 , Issue.4 , pp. 193-202
    • Kim, C.H.1    Aggarwal, R.2
  • 8
    • 2342425645 scopus 로고    scopus 로고
    • Chinese source


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.