메뉴 건너뛰기




Volumn 7, Issue 8, 2005, Pages 495-497

Visibility of normal thoracic anatomic landmarks on storage phosphor digital radiography versus conventional radiography

Author keywords

Chest X ray; Digital radiography; Normal anatomy; Thoracic imaging

Indexed keywords

ADULT; AGED; ANATOMICAL VARIATION; ARTICLE; CHI SQUARE TEST; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; DIGITAL RADIOGRAPHY; FEMALE; HUMAN; HUMAN EXPERIMENT; IMAGE ANALYSIS; INTERMETHOD COMPARISON; MALE; METHODOLOGY; NORMAL HUMAN; OBSERVER VARIATION; RADIOLOGIST; RELIABILITY; STATISTICAL SIGNIFICANCE; THORAX RADIOGRAPHY; VISIBILITY;

EID: 23344447084     PISSN: 15651088     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (9)
  • 1
    • 33644481916 scopus 로고    scopus 로고
    • Sources and effects of ionizing radiation
    • United Nations Committee on the Effects of Atomic Radiation. Sources, annex D. New York: United Nations
    • United Nations Committee on the Effects of Atomic Radiation. Sources and effects of ionizing radiation. Vol 1. Sources, annex D. Medical radiation exposure. New York: United Nations, 2000:355.
    • (2000) Medical Radiation Exposure , vol.1 , pp. 355
  • 2
    • 0033985984 scopus 로고    scopus 로고
    • Digital radiography versus conventional radiography in chest imaging: Diagnostic performance of a large-area silicon flat-panel detector in a clinical CT-controlled study
    • Garmer M, Hennigs SP, Jager HJ, et al. Digital radiography versus conventional radiography in chest imaging: diagnostic performance of a large-area silicon flat-panel detector in a clinical CT-controlled study. Am J Roentgenol 2000;174:75-80.
    • (2000) Am. J. Roentgenol. , vol.174 , pp. 75-80
    • Garmer, M.1    Hennigs, S.P.2    Jager, H.J.3
  • 4
    • 0035185721 scopus 로고    scopus 로고
    • Comparison of an amorphous silicon/cesium iodide flat-panel digital chest radiography system with screen/film and computed radiography systems: A contrast-detail phantom study
    • Rong XJ, Shaw CC, Liu X, Lemacks MR, Thompson SK. Comparison of an amorphous silicon/cesium iodide flat-panel digital chest radiography system with screen/film and computed radiography systems: a contrast-detail phantom study. Med Phys 2000;28:2328-35.
    • (2000) Med. Phys. , vol.28 , pp. 2328-2335
    • Rong, X.J.1    Shaw, C.C.2    Liu, X.3    Lemacks, M.R.4    Thompson, S.K.5
  • 5
    • 0025957224 scopus 로고
    • Mediastinal abnormalities: Detection with storage phosphor digital radiography
    • Schaefer CM, Greene R, Hall DA, et al. Mediastinal abnormalities: detection with storage phosphor digital radiography. Radiology 1991;178:169-73.
    • (1991) Radiology , vol.178 , pp. 169-173
    • Schaefer, C.M.1    Greene, R.2    Hall, D.A.3
  • 6
    • 0025008969 scopus 로고
    • Digital storage phosphor imaging versus conventional film radiography in CT-documented chest disease
    • Schaefer CM, Greene R, Oestmann JW, et al. Digital storage phosphor imaging versus conventional film radiography in CT-documented chest disease. Radiology 1990;174:207-10.
    • (1990) Radiology , vol.174 , pp. 207-210
    • Schaefer, C.M.1    Greene, R.2    Oestmann, J.W.3
  • 7
    • 0025144117 scopus 로고
    • Chest radiography: Comparison of high-resolution digital displays with conventional and digital film
    • Cox GG, Cook LT, McMillan JH, Rosenthal SJ, Dwyer SJ 3rd. Chest radiography: comparison of high-resolution digital displays with conventional and digital film. Radiology 1990;176:771-6.
    • (1990) Radiology , vol.176 , pp. 771-776
    • Cox, G.G.1    Cook, L.T.2    McMillan, J.H.3    Rosenthal, S.J.4    Dwyer III, S.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.