메뉴 건너뛰기




Volumn 43, Issue 3, 2005, Pages 535-541

Measurements of vibrotactile perception thresholds at the fingertips in Poland

Author keywords

Measuring equipment; Reference values; Vibrotactile perception threshold

Indexed keywords

ADULT; ARTICLE; CONSTRUCTION WORK; EQUIPMENT; FEMALE; FINGER; FINGER TIP; HUMAN; INTERMETHOD COMPARISON; INTERNATIONAL STANDARD UNIT; INTERNATIONAL STANDARDS ORGANIZATION; MALE; MEASUREMENT; NORMAL HUMAN; PALLESTHESIOMETER; PERCEPTIVE THRESHOLD; POLAND; REFERENCE VALUE; TOUCH; VIBRATION SENSE; VIBROTACTILE PERCEPTION THRESHOLD;

EID: 23344442513     PISSN: 00198366     EISSN: None     Source Type: Journal    
DOI: 10.2486/indhealth.43.535     Document Type: Article
Times cited : (10)

References (18)
  • 1
    • 0025332244 scopus 로고
    • Measuring method for vibration perception threshold of fingers and its application to vibration exposed workers
    • Aatola S, Färkkilä M, Pyykkö I, Korhonen O, Starck J (1990) Measuring method for vibration perception threshold of fingers and its application to vibration exposed workers. Int Arch Occup Environ Health 62, 239-42.
    • (1990) Int Arch Occup Environ Health , vol.62 , pp. 239-242
    • Aatola, S.1    Färkkilä, M.2    Pyykkö, I.3    Korhonen, O.4    Starck, J.5
  • 2
    • 0030804407 scopus 로고    scopus 로고
    • Changes over a work shift in aesthesiometric and vibrotactile perception thresholds of workers exposed to intermittent hand transmitted vibration from impact wrenches
    • Bovenzi M, Apostoli P, Alessandro G, Vanoni O (1997) Changes over a work shift in aesthesiometric and vibrotactile perception thresholds of workers exposed to intermittent hand transmitted vibration from impact wrenches. Occup Environ Med 54, 8, 577-87.
    • (1997) Occup Environ Med , vol.54 , Issue.8 , pp. 577-587
    • Bovenzi, M.1    Apostoli, P.2    Alessandro, G.3    Vanoni, O.4
  • 3
    • 0030967859 scopus 로고    scopus 로고
    • Association between a quantitative measure of tactile acuity and hand symptoms reported by operators of power tools
    • Coutu-Wakulczuk G, Brammer AJ, Piercy JE (1997) Association between a quantitative measure of tactile acuity and hand symptoms reported by operators of power tools. J Hand Surg Am 22, 873-81.
    • (1997) J Hand Surg Am , vol.22 , pp. 873-881
    • Coutu-Wakulczuk, G.1    Brammer, A.J.2    Piercy, J.E.3
  • 4
    • 0026031360 scopus 로고
    • Factors influencing vibration sense thresholds used to assess occupational exposures to hand-transmitted vibration
    • Harada N, Grriffin MJ (1991) Factors influencing vibration sense thresholds used to assess occupational exposures to hand-transmitted vibration. Br J Ind Med 48, 185-92.
    • (1991) Br J Ind Med , vol.48 , pp. 185-192
    • Harada, N.1    Grriffin, M.J.2
  • 5
    • 0012415425 scopus 로고    scopus 로고
    • Vibrotactile thresholds: Effect of contact forces and skin indentation
    • Southampton, England
    • Lindsell Ch (1997) Vibrotactile thresholds: Effect of contact forces and skin indentation. In: Proceedings of UK Group Meeting on Human Response to Vibration. 433-43, Southampton, England.
    • (1997) Proceedings of UK Group Meeting on Human Response to Vibration , pp. 433-443
    • Lindsell, Ch.1
  • 8
    • 33644492031 scopus 로고    scopus 로고
    • (1998) Pallesthesiometer P8 - Synchronous detector for measurement in condition of the mechanical interferences. Application No P 329447. Patent Office RP, Warszawa, (in Polish)
    • Czyczyło M (1998) Pallesthesiometer P8-Synchronous detector for measurement in condition of the mechanical interferences. Application No P 329447. Patent Office RP, Warszawa, (in Polish).
    • Czyczyło, M.1
  • 11
    • 0028016183 scopus 로고
    • A comparison of vibrotactile thresholds on the the finger obtained with different equipment
    • Maeda S, Griffin MJ (1994) A comparison of vibrotactile thresholds on the the finger obtained with different equipment. Ergonomics 37, 1391-406.
    • (1994) Ergonomics , vol.37 , pp. 1391-1406
    • Maeda, S.1    Griffin, M.J.2
  • 12
    • 0030750085 scopus 로고    scopus 로고
    • A comparison of vibrotactile thresholds on the finger obtained with ISO type equipment and Japanese equipment
    • Maeda S, Morioka M, Yonekawa Y, Kanada K, Takahashi Y (1997) A comparison of vibrotactile thresholds on the finger obtained with ISO type equipment and Japanese equipment. Ind Health 35, 343-52.
    • (1997) Ind Health , vol.35 , pp. 343-352
    • Maeda, S.1    Morioka, M.2    Yonekawa, Y.3    Kanada, K.4    Takahashi, Y.5
  • 14
    • 4544280828 scopus 로고    scopus 로고
    • The effect of probe size on vibrotactile thresholds at the fingertip and forearm
    • Loughborough University, UK
    • Whitehouse DJ (2002) The effect of probe size on vibrotactile thresholds at the fingertip and forearm. In: Proceedings 37th UK Conference on Human Response to Vibration. 336-47, Loughborough University, UK.
    • (2002) Proceedings 37th UK Conference on Human Response to Vibration , pp. 336-347
    • Whitehouse, D.J.1
  • 16
    • 0030006352 scopus 로고    scopus 로고
    • Vibrotactile perception thresholds as determined by two different devices in a working population
    • Wenemark M, Lundström R, Hagberg M, Nilsson T (1996) Vibrotactile perception thresholds as determined by two different devices in a working population. Scand J Work Environ Health 22, 204-10.
    • (1996) Scand J Work Environ Health , vol.22 , pp. 204-210
    • Wenemark, M.1    Lundström, R.2    Hagberg, M.3    Nilsson, T.4
  • 17
    • 4544359069 scopus 로고    scopus 로고
    • Comparison of vibrotactile thresholds in women obtained with two psychophysical measurement methods
    • in Polish
    • Harazin B, Kuprowski J, Harazin-Lechowska A (2004) Comparison of vibrotactile thresholds in women obtained with two psychophysical measurement methods. Medycyna Pracy 55, 321-8 (in Polish).
    • (2004) Medycyna Pracy , vol.55 , pp. 321-328
    • Harazin, B.1    Kuprowski, J.2    Harazin-Lechowska, A.3
  • 18
    • 0942268802 scopus 로고    scopus 로고
    • Repeatability of vibrotactile perception thresholds obtained with two different measuring systems
    • Harazin B, Kuprowski J, Stolorz G (2003) Repeatability of vibrotactile perception thresholds obtained with two different measuring systems. Int J Occup Med Environ Health 16, 311-9.
    • (2003) Int J Occup Med Environ Health , vol.16 , pp. 311-319
    • Harazin, B.1    Kuprowski, J.2    Stolorz, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.