-
1
-
-
0000622016
-
Caps for the head of the radius
-
Speed K. Caps for the head of the radius. Surg Gynecol Obstet 1941; 73:845-850.
-
(1941)
Surg Gynecol Obstet
, vol.73
, pp. 845-850
-
-
Speed, K.1
-
2
-
-
0000548011
-
Metallic cap replacement of radial head following fracture
-
Carr CR, Howard JW. Metallic cap replacement of radial head following fracture. West J Surg Obstet Gynecol 1951; 59:539-546.
-
(1951)
West J Surg Obstet Gynecol
, vol.59
, pp. 539-546
-
-
Carr, C.R.1
Howard, J.W.2
-
3
-
-
0007498567
-
Use of acrylic prosthesis in the treatment of fracture of the head of the radius
-
Cherry JC. Use of acrylic prosthesis in the treatment of fracture of the head of the radius. J Bone Joint Surg Br 1953; 35:70-71.
-
(1953)
J Bone Joint Surg Br
, vol.35
, pp. 70-71
-
-
Cherry, J.C.1
-
4
-
-
0000388725
-
Radial head prosthesis in the management of radial head fractures
-
Edwards GE, Rostrup O. Radial head prosthesis in the management of radial head fractures. Can J Surg 1960; 3:153-155.
-
(1960)
Can J Surg
, vol.3
, pp. 153-155
-
-
Edwards, G.E.1
Rostrup, O.2
-
5
-
-
0019492571
-
Comminuted fractures of the radial head: The role of silicone-implant replacement arthroplasty
-
Swanson AB, Jaeger SH, LaRochelle D. Comminuted fractures of the radial head: the role of silicone-implant replacement arthroplasty. J Bone Joint Surg Am 1981; 63:1039-1049.
-
(1981)
J Bone Joint Surg Am
, vol.63
, pp. 1039-1049
-
-
Swanson, A.B.1
Jaeger, S.H.2
LaRochelle, D.3
-
7
-
-
0026100558
-
Early failure of silicone radial head implants in the rheumatoid elbow: A complication of silicone radial head implant arthroplasty
-
Trepman E, Ewald FC. Early failure of silicone radial head implants in the rheumatoid elbow: a complication of silicone radial head implant arthroplasty. J Arthroplasty 1991; 6:59-65.
-
(1991)
J Arthroplasty
, vol.6
, pp. 59-65
-
-
Trepman, E.1
Ewald, F.C.2
-
8
-
-
0028090737
-
Inflammatory arthritis after failure of silicone rubber replacements of the radial head
-
Vanderwilde RS, Morry BF, Melberg MW, et al. Inflammatory arthritis after failure of silicone rubber replacements of the radial head. J Bone Joint Surg Br 1994; 76:78-81.
-
(1994)
J Bone Joint Surg Br
, vol.76
, pp. 78-81
-
-
Vanderwilde, R.S.1
Morry, B.F.2
Melberg, M.W.3
-
9
-
-
0027324303
-
Primary replacement of the fractured radial head with a metal prosthesis
-
Knight DJ, Rymaszewski LA, Amis AA, et al. Primary replacement of the fractured radial head with a metal prosthesis. J Bone Joint Surg Br 1993; 75:572-576.
-
(1993)
J Bone Joint Surg Br
, vol.75
, pp. 572-576
-
-
Knight, D.J.1
Rymaszewski, L.A.2
Amis, A.A.3
-
10
-
-
0034897342
-
Arthroplasty with a metal radial head for unreconstructable fractures of the radial head
-
Moro JK, Werier J, MacDermid JC, et al. Arthroplasty with a metal radial head for unreconstructable fractures of the radial head. J Bone Joint Surg Am 2001; 83:1201-1211.
-
(2001)
J Bone Joint Surg Am
, vol.83
, pp. 1201-1211
-
-
Moro, J.K.1
Werier, J.2
MacDermid, J.C.3
-
11
-
-
0034151040
-
Fracture of the radial head with associated elbow dislocation: Results of treatment using a floating radial head prosthesis
-
Popovic N, Gillet P, Rodriguez A, et al. Fracture of the radial head with associated elbow dislocation: results of treatment using a floating radial head prosthesis. J Orthop Trauma 2000; 14:171-177.
-
(2000)
J Orthop Trauma
, vol.14
, pp. 171-177
-
-
Popovic, N.1
Gillet, P.2
Rodriguez, A.3
-
12
-
-
0033748108
-
The floating radial head prosthesis for comminuted radial head fractures: A multicentric study
-
Smets S, Govaers K, Jansen N, et al. The floating radial head prosthesis for comminuted radial head fractures: a multicentric study. Acta Orthop Belg 2000; 66:353-358.
-
(2000)
Acta Orthop Belg
, vol.66
, pp. 353-358
-
-
Smets, S.1
Govaers, K.2
Jansen, N.3
-
13
-
-
11844280818
-
Comminuted fractures of the radial head: Comparison of resection and internal fixation
-
Ikeda M, Sugiyama K, Kang C, et al. Comminuted fractures of the radial head: comparison of resection and internal fixation. J Bone Joint Surg Am 2005; 87:76-84. This paper evaluates patients who underwent fixation of radial head fractures with miniplates or Herbert screws and had better outcomes than patients who underwent excision.
-
(2005)
J Bone Joint Surg Am
, vol.87
, pp. 76-84
-
-
Ikeda, M.1
Sugiyama, K.2
Kang, C.3
-
14
-
-
0942301372
-
Management of Mason type-III radial head fracture with a titanium prosthesis, ligament repair, and early mobilization
-
Ashwood N, Bain G, Unni R. Management of Mason type-III radial head fracture with a titanium prosthesis, ligament repair, and early mobilization. J Bone Joint Surg Am 2004; 86:274-280. This paper is a good reference for the technique of radial head arthroplasty with a titanium implant and the importance of ligamentous stability for early range of motion.
-
(2004)
J Bone Joint Surg Am
, vol.86
, pp. 274-280
-
-
Ashwood, N.1
Bain, G.2
Unni, R.3
-
15
-
-
4544333300
-
Fractures of the radial head and neck treated with radial head excision
-
Herbertsson P, Josefsson O, Hasserius R, et al. Fractures of the radial head and neck treated with radial head excision. J Bone Joint Surg Am 2004; 86:1925-1930. This is an excellent study with an average of 18 years of follow-up of patients who underwent radial head excision. This study has the largest study group and longest follow-up to date.
-
(2004)
J Bone Joint Surg Am
, vol.86
, pp. 1925-1930
-
-
Herbertsson, P.1
Josefsson, O.2
Hasserius, R.3
-
16
-
-
0038189779
-
Intra-articular fractures of the upper extremity: New concepts in surgical treatment
-
Boyer M, Galatz L, Borelli J, et al. Intra-articular fractures of the upper extremity: new concepts in surgical treatment. Instr Course Lect 2003; 52:591-605.
-
(2003)
Instr Course Lect
, vol.52
, pp. 591-605
-
-
Boyer, M.1
Galatz, L.2
Borelli, J.3
-
18
-
-
11044231272
-
The effect of radial head fracture size on elbow kinematics and stability
-
Beingessner DM, Dunning CE, Gordon KD, et al. The effect of radial head fracture size on elbow kinematics and stability. J Orthop Res 2005; 23:210-217. This is an excellent biomechanical evaluation of the effects of radial head fracture and ligamentous disruption to the stability of the elbow.
-
(2005)
J Orthop Res
, vol.23
, pp. 210-217
-
-
Beingessner, D.M.1
Dunning, C.E.2
Gordon, K.D.3
-
19
-
-
0042670057
-
The effect of radial head fracture size on radiocapitellar joint stability
-
Beingessner DM, Dunning CE, Beingessner CJ, et al. The effect of radial head fracture size on radiocapitellar joint stability. Clin Biomech (Bristol, Avon) 2003; 18:677-684.
-
(2003)
Clin Biomech (Bristol, Avon)
, vol.18
, pp. 677-684
-
-
Beingessner, D.M.1
Dunning, C.E.2
Beingessner, C.J.3
-
20
-
-
0036799350
-
Open reduction and internal fixation of fractures of the radial head
-
Ring D, Quintero J, Jupiter JB. Open reduction and internal fixation of fractures of the radial head. J Bone Joint Surg Am 2002; 84:1811-1815.
-
(2002)
J Bone Joint Surg Am
, vol.84
, pp. 1811-1815
-
-
Ring, D.1
Quintero, J.2
Jupiter, J.B.3
-
21
-
-
0025982399
-
Open reduction and internal fixation of radial head fractures
-
King GJ, Evans DC, Kellam JF. Open reduction and internal fixation of radial head fractures. J Orthop Trauma 1991; 5:21-28.
-
(1991)
J Orthop Trauma
, vol.5
, pp. 21-28
-
-
King, G.J.1
Evans, D.C.2
Kellam, J.F.3
-
22
-
-
2642572872
-
Standard surgical protocol to treat elbow dislocations with radial head and coronoid fractures
-
Pugh DM, Wild LM, Schemitsch EH, et al. Standard surgical protocol to treat elbow dislocations with radial head and coronoid fractures. J Bone Joint Surg Am 2004; 86:1122-1130. This article is a good reference for the protocol to address elbow dislocations.
-
(2004)
J Bone Joint Surg Am
, vol.86
, pp. 1122-1130
-
-
Pugh, D.M.1
Wild, L.M.2
Schemitsch, E.H.3
-
23
-
-
0031754922
-
The column procedure: A limited lateral approach for extrinsic contracture of the elbow
-
Mansat P, Morrey BF. The column procedure: a limited lateral approach for extrinsic contracture of the elbow. J Bone Joint Surg Am 1998; 80:1603-1615.
-
(1998)
J Bone Joint Surg Am
, vol.80
, pp. 1603-1615
-
-
Mansat, P.1
Morrey, B.F.2
-
24
-
-
0034041685
-
Anatomical considerations regarding the posterior interosseous nerve during posterolateral approaches to the proximal part of the radius
-
Diliberti T, Botte MJ, Abrams RA. Anatomical considerations regarding the posterior interosseous nerve during posterolateral approaches to the proximal part of the radius. J Bone Joint Surg Am 2000; 82:809-813.
-
(2000)
J Bone Joint Surg Am
, vol.82
, pp. 809-813
-
-
Diliberti, T.1
Botte, M.J.2
Abrams, R.A.3
-
25
-
-
0015059836
-
Vulnerability of the posterior interosseous nerve during radial head resection
-
Strachan JCH, Ellis BW. Vulnerability of the posterior interosseous nerve during radial head resection. J Bone Joint Surg Br 1981; 53:320-323.
-
(1981)
J Bone Joint Surg Br
, vol.53
, pp. 320-323
-
-
Strachan, J.C.H.1
Ellis, B.W.2
-
26
-
-
0041560075
-
A radiographic study of proximal radius anatomy with implications in radial head replacement
-
Roidis N, Stevanovic M, Martirosian A, et al. A radiographic study of proximal radius anatomy with implications in radial head replacement. J Shoulder Elbow Surg 2003; 12:380-384.
-
(2003)
J Shoulder Elbow Surg
, vol.12
, pp. 380-384
-
-
Roidis, N.1
Stevanovic, M.2
Martirosian, A.3
-
27
-
-
0347003753
-
Radial head prosthesis with a mobile head
-
Skalski K, Swieszkowski W, Pomianowski S, et al. Radial head prosthesis with a mobile head. J Shoulder Elbow Surg 2004; 13:78-85. This article addresses the bipolar radial head design and is a good biomechanical summary for factors influencing prosthetic design and selection.
-
(2004)
J Shoulder Elbow Surg
, vol.13
, pp. 78-85
-
-
Skalski, K.1
Swieszkowski, W.2
Pomianowski, S.3
-
28
-
-
2442488656
-
Capitellar erosion caused by a metal head prosthesis: A case report
-
Van Riet RP, VanGlabbeek F, Verborgt O, Gielen J. Capitellar erosion caused by a metal head prosthesis: a case report. J Bone Joint Surg Am 2004; 86:1061-1064. This article addresses complications of radial head arthroplasty.
-
(2004)
J Bone Joint Surg Am
, vol.86
, pp. 1061-1064
-
-
Van Riet, R.P.1
Vanglabbeek, F.2
Verborgt, O.3
Gielen, J.4
-
30
-
-
0036913418
-
Biometry of the radial head: Biomechanical implications in pronation and supination
-
Captier G, Canovas F, Mercier N, et al. Biometry of the radial head: biomechanical implications in pronation and supination. Surg Radiol Anat 2002; 24:295-301.
-
(2002)
Surg Radiol Anat
, vol.24
, pp. 295-301
-
-
Captier, G.1
Canovas, F.2
Mercier, N.3
-
34
-
-
1242329810
-
Morphology of the radial head: A reverse engineering based on evaluation using three-dimensional anatomical data of radial bone
-
Mahaisavariya B, Saekee B, Sitthiseripratip K, et al. Morphology of the radial head: a reverse engineering based on evaluation using three-dimensional anatomical data of radial bone. Proc Inst Mech Eng [H] 2004; 218:79-84. This is another study addressing the morphology of the radial head but using re-verse engineering with CT reconstructing as a new approach. It was found that the head thickness was approximately 13 mm.
-
(2004)
Proc Inst Mech Eng [H]
, vol.218
, pp. 79-84
-
-
Mahaisavariya, B.1
Saekee, B.2
Sitthiseripratip, K.3
-
35
-
-
2442499268
-
Coronoid process and radial head as posterolateral rotatory stabilizers of the elbow
-
Schneeberger AG, Sadowski MM, Jacob HA. Coronoid process and radial head as posterolateral rotatory stabilizers of the elbow. J Bone Joint Surg Am 2004; 86:975-982. This article was a strong laboratory study showing that elbow stability was better with a rigid implant vs a floating prosthesis.
-
(2004)
J Bone Joint Surg Am
, vol.86
, pp. 975-982
-
-
Schneeberger, A.G.1
Sadowski, M.M.2
Jacob, H.A.3
-
36
-
-
0037301759
-
The effect of metallic radial head arthroplasty on radiocapitellar joint contact area
-
Liew VS, Cooper IC, Ferreira LM, et al. The effect of metallic radial head arthroplasty on radiocapitellar joint contact area. Clin Biomech (Bristol, Avon) 2003; 18:115-118.
-
(2003)
Clin Biomech (Bristol, Avon)
, vol.18
, pp. 115-118
-
-
Liew, V.S.1
Cooper, I.C.2
Ferreira, L.M.3
-
38
-
-
10344234202
-
Detrimental effects of overstuffing or understuffing with a radial head replacement in the medial collateral-ligament deficient elbow
-
Van Glabbeek F, Van Riet RP, Baunfeld JA, et al. Detrimental effects of overstuffing or understuffing with a radial head replacement in the medial collateral-ligament deficient elbow. J Bone Joint Surg Am 2004; 86:2629-2635. This is an excellent paper that defines, biomechanically, the limits for prosthesis placement that will produce 'overstuffing' or 'understuffing' of the elbow.
-
(2004)
J Bone Joint Surg Am
, vol.86
, pp. 2629-2635
-
-
Van Glabbeek, F.1
Van Riet, R.P.2
Baunfeld, J.A.3
-
39
-
-
0035992679
-
Fractures of the elbow's lateral column radial head and capitellum
-
Rizzo M, Nunley JA. Fractures of the elbow's lateral column radial head and capitellum. Hand Clin 2002; 18:21-42.
-
(2002)
Hand Clin
, vol.18
, pp. 21-42
-
-
Rizzo, M.1
Nunley, J.A.2
-
40
-
-
8144231039
-
Management of comminuted radial head fractures with replacement arthroplasty
-
King GJ. Management of comminuted radial head fractures with replacement arthroplasty. Hand Clin 2004; 20:429-441.
-
(2004)
Hand Clin
, vol.20
, pp. 429-441
-
-
King, G.J.1
-
41
-
-
8144230347
-
Open reduction and internal fixation of fractures of the radial head
-
Ring D. Open reduction and internal fixation of fractures of the radial head. Hand Clin 2004; 20:415-427.
-
(2004)
Hand Clin
, vol.20
, pp. 415-427
-
-
Ring, D.1
|