메뉴 건너뛰기




Volumn 74, Issue 1, 2005, Pages 124-140

Effects of soluble metals on human peri-implant cells

Author keywords

Fibroblasts; Lymphocytes; Metal ion; Metal toxicity; MG 63 osteoblasts; Osteolysis

Indexed keywords

BIOASSAY; IMMUNOLOGY; MORPHOLOGY; TISSUE; TITANIUM ALLOYS; TOXIC MATERIALS; TOXICITY;

EID: 23244457380     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/jbm.a.30345     Document Type: Article
Times cited : (117)

References (50)
  • 1
    • 0345356514 scopus 로고    scopus 로고
    • Biologic response to orthopedic implants
    • Buckwalter JA, Einhorn TA, Simon S, editors. Chicago, IL: American Academy of Orthopedic Surgeons
    • Jacobs J, Goodman S, Sumner DR, Hallab N. Biologic response to orthopedic implants. In: Buckwalter JA, Einhorn TA, Simon S, editors. Orthopedic basic science. Chicago, IL: American Academy of Orthopedic Surgeons; 1999. p 402-426.
    • (1999) Orthopedic Basic Science , pp. 402-426
    • Jacobs, J.1    Goodman, S.2    Sumner, D.R.3    Hallab, N.4
  • 3
    • 0033333278 scopus 로고    scopus 로고
    • Metal-on-metal hip replacements: Wear performance and cellular response to wear particles
    • Disegi R, Kennedy RL, Pilliar RM, editors. ASTM STP 1365. West Conshohocken, PA: American Society for Testing and Materials
    • Campbell PA, McKellop H, Alim Mirra J, Nutt S, Amstutz HC. Metal-on-metal hip replacements: Wear performance and cellular response to wear particles. In: Disegi R, Kennedy RL, Pilliar RM, editors. Cobalt-base alloys for biomedical applications, ASTM STP 1365. West Conshohocken, PA: American Society for Testing and Materials; 1999. p 193-200.
    • (1999) Cobalt-Base Alloys for Biomedical Applications , pp. 193-200
    • Campbell, P.A.1    McKellop, H.2    Alim Mirra, J.3    Nutt, S.4    Amstutz, H.C.5
  • 4
    • 0023741339 scopus 로고
    • Formation of a fulminant soft-tissue pseudotumor after uncemented hip arthroplasty. A case report
    • Svensson O, Mathiesen EB, Reinholt FP, Blomgren G. Formation of a fulminant soft-tissue pseudotumor after uncemented hip arthroplasty. A case report. J Bone Joint Surg Am 1988;70: 1238-1242.
    • (1988) J Bone Joint Surg Am , vol.70 , pp. 1238-1242
    • Svensson, O.1    Mathiesen, E.B.2    Reinholt, F.P.3    Blomgren, G.4
  • 7
    • 0031816246 scopus 로고    scopus 로고
    • In vitro, in vivo, and tissue retrieval studies on particulate debris
    • Goodman SB, Lind M, Song Y, Smith RL. In vitro, in vivo, and tissue retrieval studies on particulate debris. Clin Orthop 1998; 352:25-34.
    • (1998) Clin Orthop , vol.352 , pp. 25-34
    • Goodman, S.B.1    Lind, M.2    Song, Y.3    Smith, R.L.4
  • 8
    • 0026577202 scopus 로고
    • Metallic debris in femoral endosteolysis in failed cemented total hip arthroplasties
    • Huo MH, Salvati EA, Lieberman JR, Betts F, Bansal M. Metallic debris in femoral endosteolysis in failed cemented total hip arthroplasties. Clin Orthop 1992;276:157-168.
    • (1992) Clin Orthop , vol.276 , pp. 157-168
    • Huo, M.H.1    Salvati, E.A.2    Lieberman, J.R.3    Betts, F.4    Bansal, M.5
  • 11
    • 0028073911 scopus 로고
    • Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings
    • Urban RM, Jacobs JJ, Gilbert JL, Galante JO. Migration of corrosion products from modular hip prostheses. Particle microanalysis and histopathological findings. J Bone Joint Surg Am 1994;76:1345-1359.
    • (1994) J Bone Joint Surg Am , vol.76 , pp. 1345-1359
    • Urban, R.M.1    Jacobs, J.J.2    Gilbert, J.L.3    Galante, J.O.4
  • 12
    • 0008757913 scopus 로고    scopus 로고
    • Particles of metal alloys and their corrosion products in the liver, spleen and para-aortic lymph nodes of patients with total hip replacement prosthesis
    • Urban RM, Jacobs JJ, Tomlinson MJ, Black J, Turner TM, Sauer PA, Galante JO. Particles of metal alloys and their corrosion products in the liver, spleen and para-aortic lymph nodes of patients with total hip replacement prosthesis. Orthop Trans 1996;19:1107-1108.
    • (1996) Orthop Trans , vol.19 , pp. 1107-1108
    • Urban, R.M.1    Jacobs, J.J.2    Tomlinson, M.J.3    Black, J.4    Turner, T.M.5    Sauer, P.A.6    Galante, J.O.7
  • 13
    • 0025679122 scopus 로고
    • Histologic, biochemical and ion analysis of tissue and fluids retrieved during total hip arthroplasty
    • Dorr LD, Bloebaum R, Emmanual J, Meldrum R. Histologic, biochemical and ion analysis of tissue and fluids retrieved during total hip arthroplasty. Clin Orthop Relat Res 1990;261: 82-95.
    • (1990) Clin Orthop Relat Res , vol.261 , pp. 82-95
    • Dorr, L.D.1    Bloebaum, R.2    Emmanual, J.3    Meldrum, R.4
  • 15
    • 0026013091 scopus 로고
    • Systemic effects of implanted prostheses made of cobalt-chromium alloys
    • Michel R, Nolte M, Reich M, Loer F. Systemic effects of implanted prostheses made of cobalt-chromium alloys. Arch Orthop Trauma Surg 1991;110:61-74.
    • (1991) Arch Orthop Trauma Surg , vol.110 , pp. 61-74
    • Michel, R.1    Nolte, M.2    Reich, M.3    Loer, F.4
  • 16
    • 0028404427 scopus 로고
    • Metallic wear debris in metal-backed patellar failure
    • Stulberg BN, Merritt K, Bauer T. Metallic wear debris in metal-backed patellar failure. J Biomed Mater Res 1994;5:9-16.
    • (1994) J Biomed Mater Res , vol.5 , pp. 9-16
    • Stulberg, B.N.1    Merritt, K.2    Bauer, T.3
  • 19
    • 0034117155 scopus 로고    scopus 로고
    • Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement
    • Urban RM, Jacobs JJ, Tomlinson MJ, Gavrilovic J, Black J, Peoc'h M. Dissemination of wear particles to the liver, spleen, and abdominal lymph nodes of patients with hip or knee replacement. J Bone Joint Sur Am 2000;82:457-476.
    • (2000) J Bone Joint Sur Am , vol.82 , pp. 457-476
    • Urban, R.M.1    Jacobs, J.J.2    Tomlinson, M.J.3    Gavrilovic, J.4    Black, J.5    Peoc'H, M.6
  • 20
    • 0031051717 scopus 로고    scopus 로고
    • In vitro lymphocyte proliferation as compared to patch test using gold, palladium and nickel
    • Cederbrant K, Hultman P, Marcusson JA, Tibbling L. In vitro lymphocyte proliferation as compared to patch test using gold, palladium and nickel. Int Arch Allergy Immunol 1997;112:212-217.
    • (1997) Int Arch Allergy Immunol , vol.112 , pp. 212-217
    • Cederbrant, K.1    Hultman, P.2    Marcusson, J.A.3    Tibbling, L.4
  • 21
    • 0031033347 scopus 로고    scopus 로고
    • Effects of metal ions on osteoblast-like cell metabolism and differentiation
    • Sun ZL, Wataha JC, Hanks CT. Effects of metal ions on osteoblast-like cell metabolism and differentiation. J Biomed Mater Res 1997;34:29-37.
    • (1997) J Biomed Mater Res , vol.34 , pp. 29-37
    • Sun, Z.L.1    Wataha, J.C.2    Hanks, C.T.3
  • 22
    • 0028440256 scopus 로고
    • Effect of cell line on in vitro metal ion cytotoxicity
    • Wataha JC, Hanks CT, Sun Z. Effect of cell line on in vitro metal ion cytotoxicity. Dent Mater 1994;10:156-161.
    • (1994) Dent Mater , vol.10 , pp. 156-161
    • Wataha, J.C.1    Hanks, C.T.2    Sun, Z.3
  • 23
    • 0028414093 scopus 로고
    • In vitro effects of metal ions on cellular metabolism and the correlation between these effects and the uptake of the ions
    • Wataha JC, Hanks CT, Craig RG. In vitro effects of metal ions on cellular metabolism and the correlation between these effects and the uptake of the ions. J Biomed Mater Res 1994;28: 427-433.
    • (1994) J Biomed Mater Res , vol.28 , pp. 427-433
    • Wataha, J.C.1    Hanks, C.T.2    Craig, R.G.3
  • 24
    • 0027601602 scopus 로고
    • The effect of cell monolayer density on the cytotoxicity of metal ions which are released from dental alloys
    • Wataha JC, Hanks CT, Craig RG. The effect of cell monolayer density on the cytotoxicity of metal ions which are released from dental alloys. Dent Mater 1993;9:172-176.
    • (1993) Dent Mater , vol.9 , pp. 172-176
    • Wataha, J.C.1    Hanks, C.T.2    Craig, R.G.3
  • 25
    • 0031149063 scopus 로고    scopus 로고
    • Effect of metal ions on the formation and function of osteoclastic cells in vitro
    • Nichols KG, Puleo DA. Effect of metal ions on the formation and function of osteoclastic cells in vitro. J Biomed Mater Res 1997;35:265-271.
    • (1997) J Biomed Mater Res , vol.35 , pp. 265-271
    • Nichols, K.G.1    Puleo, D.A.2
  • 26
    • 0030272024 scopus 로고    scopus 로고
    • Ti-6A1-4V ion solution inhibition of osteogenic cell phenotype as a function of differentiation time-course in vitro
    • Thompson GJ, Puleo DA. Ti-6A1-4V ion solution inhibition of osteogenic cell phenotype as a function of differentiation time-course in vitro. Biomaterials 1996;17:1949-1954.
    • (1996) Biomaterials , vol.17 , pp. 1949-1954
    • Thompson, G.J.1    Puleo, D.A.2
  • 27
    • 0029415085 scopus 로고
    • Effects of sublethal metal ion concentrations on osteogenic cells derived from bone marrow stromal cells
    • Thompson GJ, Puleo DA. Effects of sublethal metal ion concentrations on osteogenic cells derived from bone marrow stromal cells. J Appl Biomater 1995;6:249-258.
    • (1995) J Appl Biomater , vol.6 , pp. 249-258
    • Thompson, G.J.1    Puleo, D.A.2
  • 28
    • 0029311024 scopus 로고
    • Acute toxicity of metal ions in cultures of osteogenic cells derived from bone marrow stromal cells
    • Puleo DA, Huh WW. Acute toxicity of metal ions in cultures of osteogenic cells derived from bone marrow stromal cells. J Appl Biomater 1995;6:109-116.
    • (1995) J Appl Biomater , vol.6 , pp. 109-116
    • Puleo, D.A.1    Huh, W.W.2
  • 29
    • 0033080559 scopus 로고    scopus 로고
    • In vitro osteoblastic differentiation of human bone marrow cells in the presence of metal ions
    • Morais S, Dias N, Sousa JP, Fernandes MH, Carvalho GS. In vitro osteoblastic differentiation of human bone marrow cells in the presence of metal ions. J Biomed Mater Res 1999;44:176-190.
    • (1999) J Biomed Mater Res , vol.44 , pp. 176-190
    • Morais, S.1    Dias, N.2    Sousa, J.P.3    Fernandes, M.H.4    Carvalho, G.S.5
  • 31
    • 0031812308 scopus 로고    scopus 로고
    • In vitro biomineralization by osteoblast-like cells. I. Retardation of tissue mineralization by metal salts
    • Morais S, Sousa JP, Fernandes MH, Carvalho GS. In vitro biomineralization by osteoblast-like cells. I. Retardation of tissue mineralization by metal salts. Biomaterials 1998;19:13-21.
    • (1998) Biomaterials , vol.19 , pp. 13-21
    • Morais, S.1    Sousa, J.P.2    Fernandes, M.H.3    Carvalho, G.S.4
  • 33
    • 0031606991 scopus 로고    scopus 로고
    • Uptake and reversibility of uptake of nickel by human macrophages
    • Edwards DL, Wataha JC, Hanks CT. Uptake and reversibility of uptake of nickel by human macrophages. J Oral Rehabil 1998;25:2-7.
    • (1998) J Oral Rehabil , vol.25 , pp. 2-7
    • Edwards, D.L.1    Wataha, J.C.2    Hanks, C.T.3
  • 34
    • 0030906354 scopus 로고    scopus 로고
    • Prosthetic metals interfere with the functions of human osteoblast cells in vitro
    • Wang JY, Wicklund BH, Gustilo RB, Tsukayama DT. Prosthetic metals interfere with the functions of human osteoblast cells in vitro. Clin Orthop Relat Res 1997;339:216-226.
    • (1997) Clin Orthop Relat Res , vol.339 , pp. 216-226
    • Wang, J.Y.1    Wicklund, B.H.2    Gustilo, R.B.3    Tsukayama, D.T.4
  • 37
    • 0141464869 scopus 로고    scopus 로고
    • Interfacial kinetics of titanium-and cobalt-based implant alloys in human serum: Metal release and biofilm formation
    • Hallab NJ, Skipor A, Jacobs JJ. Interfacial kinetics of titanium-and cobalt-based implant alloys in human serum: metal release and biofilm formation. J Biomed Mater Res 2003;65A:311-318.
    • (2003) J Biomed Mater Res , vol.65 A , pp. 311-318
    • Hallab, N.J.1    Skipor, A.2    Jacobs, J.J.3
  • 40
    • 0020965469 scopus 로고
    • Serum concentrations of chromium, cobalt, and nickel after total hip replacement: A six month study
    • Black J, Maitin EC, Gelman H, Morris DM. Serum concentrations of chromium, cobalt, and nickel after total hip replacement: a six month study. Biomaterials 1983;4:160-164.
    • (1983) Biomaterials , vol.4 , pp. 160-164
    • Black, J.1    Maitin, E.C.2    Gelman, H.3    Morris, D.M.4
  • 41
    • 0034285013 scopus 로고    scopus 로고
    • The osteoblast: A sophisticated fibroblast under central surveillance
    • Ducy P, Schinke T, Karsenty G. The osteoblast: a sophisticated fibroblast under central surveillance. Science 2000;289:1501-1504.
    • (2000) Science , vol.289 , pp. 1501-1504
    • Ducy, P.1    Schinke, T.2    Karsenty, G.3
  • 42
    • 0033662188 scopus 로고    scopus 로고
    • Cbfa1: A molecular switch in osteoblast biology
    • Ducy P. Cbfa1: a molecular switch in osteoblast biology. Dev Dyn 2000;219:461-471.
    • (2000) Dev Dyn , vol.219 , pp. 461-471
    • Ducy, P.1
  • 43
    • 0001488906 scopus 로고
    • Corrosion of metallic implants
    • Stauffer RN, editor. St. Louis, MO: Mosby
    • Jacobs JJ, Gilbert JL, Urban RM. Corrosion of metallic implants. In: Stauffer RN, editor. Advances in orthopaedic surgery. Vol 2. St. Louis, MO: Mosby; 1994. p 279-319.
    • (1994) Advances in Orthopaedic Surgery , vol.2 , pp. 279-319
    • Jacobs, J.J.1    Gilbert, J.L.2    Urban, R.M.3
  • 48
    • 33644480250 scopus 로고    scopus 로고
    • Differential metal release and protein binding associated with titanium and cobalt-chromium implant alloys
    • Orlando, FL
    • Hallab NJ, Mikecz K, Akrami J, Jacobs J. Differential metal release and protein binding associated with titanium and cobalt-chromium implant alloys. Trans 46th Orthop Res Soc 2000, Orlando, FL.
    • (2000) Trans 46th Orthop Res Soc
    • Hallab, N.J.1    Mikecz, K.2    Akrami, J.3    Jacobs, J.4
  • 50
    • 0022602556 scopus 로고
    • The in vitro toxicity of cobalt-chromemolybdenum alloy and its constituent metals
    • Evans EJ, Thomas IT. The in vitro toxicity of cobalt-chromemolybdenum alloy and its constituent metals. Biomaterials 1986;7:25-29.
    • (1986) Biomaterials , vol.7 , pp. 25-29
    • Evans, E.J.1    Thomas, I.T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.