메뉴 건너뛰기




Volumn 5693, Issue , 2005, Pages 450-458

Data optimization for enhancing robustness of time-resolved reflectance diffuse optical tomography to optode position uncertainty

Author keywords

Data type; Diffuse optical tomography; Generalized pulse spectrum technique; Image reconstruction algorithm; Time resolved detection

Indexed keywords

ALGORITHMS; DIFFUSION; FLUORESCENCE; IMAGE RECONSTRUCTION; INTEGRAL EQUATIONS; LAPLACE TRANSFORMS; OPTIMIZATION; REFLECTION; ROBUSTNESS (CONTROL SYSTEMS); SPECTRUM ANALYSIS; SPURIOUS SIGNAL NOISE; TOMOGRAPHY;

EID: 23244446800     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.585694     Document Type: Conference Paper
Times cited : (1)

References (18)
  • 5
    • 0030717592 scopus 로고    scopus 로고
    • Noninvasive optical imaging of the subarachnoid space and cerebrospinal fluid pathways based on near-infrared fluorescence
    • K. Sakatani, M. KashiwasakeJibu, S. Wang, H. Zuo, K. Yamamoto, and K. Shimizu, "Noninvasive optical imaging of the subarachnoid space and cerebrospinal fluid pathways based on near-infrared fluorescence," Journal Of Neurosurgery 87,738-745 (1997).
    • (1997) Journal of Neurosurgery , vol.87 , pp. 738-745
    • Sakatani, K.1    KashiwasakeJibu, M.2    Wang, S.3    Zuo, H.4    Yamamoto, K.5    Shimizu, K.6
  • 7
    • 0000833455 scopus 로고    scopus 로고
    • Simultaneous imaging and optode calibration with diffuse optical tomography
    • D.A. Boas, T.J. Gaudette and S.R. Arridge, "Simultaneous imaging and optode calibration with diffuse optical tomography," Opt. Express 8, 263-270 (2001).
    • (2001) Opt. Express , vol.8 , pp. 263-270
    • Boas, D.A.1    Gaudette, T.J.2    Arridge, S.R.3
  • 8
    • 0032770502 scopus 로고    scopus 로고
    • Application of temporal filters to time resolved data in optical tomography
    • M. Schweiger and S.R. Arridge, "Application of temporal filters to time resolved data in optical tomography Phys. Med. Biol. 44, 1699-1717 (1999).
    • (1999) Phys. Med. Biol. , vol.44 , pp. 1699-1717
    • Schweiger, M.1    Arridge, S.R.2
  • 9
    • 0036458790 scopus 로고    scopus 로고
    • Time-resolved diffuse optical tomography using a modified generalized pulse spectrum technique
    • F. Gao, H. Zhao, Y. Tanikawa, Y. Yamada, "Time-resolved diffuse optical tomography using a modified generalized pulse spectrum technique," IEICE Trans. Inf. and Sys., E85-D, 133-142 (2002).
    • (2002) IEICE Trans. Inf. and Sys. , vol.E85-D , pp. 133-142
    • Gao, F.1    Zhao, H.2    Tanikawa, Y.3    Yamada, Y.4
  • 10
    • 1642569117 scopus 로고    scopus 로고
    • Optical tomographic mapping of cerebral haemodynamics by means of time-domain detection: Methodology and phantom validation
    • F. Gao, H.J. Zhao, Y. Tanikawa, and Y. Yamada, "Optical tomographic mapping of cerebral haemodynamics by means of time-domain detection: methodology and phantom validation," Phys. Med. Biol. 49, 1055-1078 (2004).
    • (2004) Phys. Med. Biol. , vol.49 , pp. 1055-1078
    • Gao, F.1    Zhao, H.J.2    Tanikawa, Y.3    Yamada, Y.4
  • 12
    • 0035723073 scopus 로고    scopus 로고
    • The accuracy of near infrared spectroscopy and imaging during focal changes in cerebral hemodynamics
    • D.A. Boas, T. Gaudette, G. Strangman, X. Cheng, J.J.A. Marota, and J.B. Mandeville, "The accuracy of near infrared spectroscopy and imaging during focal changes in cerebral hemodynamics," Neurolmage 13, 76-90 (2001).
    • (2001) Neurolmage , vol.13 , pp. 76-90
    • Boas, D.A.1    Gaudette, T.2    Strangman, G.3    Cheng, X.4    Marota, J.J.A.5    Mandeville, J.B.6
  • 13
    • 0036462564 scopus 로고    scopus 로고
    • Improvement of image quality in diffuse optical tomography by use of full time-resolved data
    • F. Gao, H. Zhao and Y. Yamada, "Improvement of image quality in diffuse optical tomography by use of full time-resolved data," Appl. Opt. 41, 778-791 (2002).
    • (2002) Appl. Opt. , vol.41 , pp. 778-791
    • Gao, F.1    Zhao, H.2    Yamada, Y.3
  • 14
    • 0032638277 scopus 로고    scopus 로고
    • Optical tomography in medical imaging
    • S.R. Arridge, "Optical tomography in medical imaging," Inverse Problems 15, R41-93, (1999).
    • (1999) Inverse Problems , vol.15
    • Arridge, S.R.1
  • 15
    • 0000350763 scopus 로고    scopus 로고
    • Simultaneous mapping of absorption and scattering coefficients from full three-dimensional model of time-resolved optical tomography
    • F. Gao, P. Poulet and Y. Yamada, "Simultaneous Mapping of Absorption and Scattering Coefficients from Full Three-Dimensional Model of Time-Resolved Optical Tomography," Applied Optics, 39, 5898-5910 (2000).
    • (2000) Applied Optics , vol.39 , pp. 5898-5910
    • Gao, F.1    Poulet, P.2    Yamada, Y.3
  • 16
    • 77949678241 scopus 로고
    • Photon measurement density functions. Part 1: Analytic forms
    • S.R. Arridge, "Photon measurement density functions. Part 1: Analytic forms," Appl. Opt. 34, 7395-7409 (1995).
    • (1995) Appl. Opt. , vol.34 , pp. 7395-7409
    • Arridge, S.R.1
  • 17
    • 84970996719 scopus 로고
    • Photon measurement density functions. Part 2: Finite element calculations
    • S.R. Arridge and M. Schweiger, "Photon measurement density functions. Part 2: Finite element calculations," Appl. Opt. 34, 8026-8037 (1995).
    • (1995) Appl. Opt. , vol.34 , pp. 8026-8037
    • Arridge, S.R.1    Schweiger, M.2
  • 18
    • 0036882089 scopus 로고    scopus 로고
    • Semi-three-dimensional algorithm for time-resolved diffuse optical tomography by use of the generalized pulse spectrum technique
    • F. Gao, Y. Tanikawa, H.J. Zhao and Y. Yamada, "Semi-three- dimensional algorithm for time-resolved diffuse optical tomography by use of the generalized pulse spectrum technique," Applied Optics, Vol. 41, 7346-7358 (2002).
    • (2002) Applied Optics , vol.41 , pp. 7346-7358
    • Gao, F.1    Tanikawa, Y.2    Zhao, H.J.3    Yamada, Y.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.