메뉴 건너뛰기




Volumn 9, Issue 1, 2005, Pages 68-72

Near-continuous, noninvasive blood pressure monitoring in the out-of-hospital setting

Author keywords

Air transport; Blood pressure; EMS; Monitoring; Prehospital

Indexed keywords

ADULT; ARTICLE; BLOOD PRESSURE MONITORING; CLINICAL ARTICLE; CONTROLLED STUDY; CUFF; EMERGENCY HEALTH SERVICE; FEMALE; HUMAN; MALE; NON INVASIVE MEASUREMENT; PATIENT TRANSPORT; PROSPECTIVE STUDY; RADIAL ARTERY; TONOMETRY; AGED; AIR MEDICAL TRANSPORT; AMBULANCE; BLOOD PRESSURE MEASUREMENT; COMPARATIVE STUDY; EQUIPMENT; EQUIPMENT DESIGN; INSTRUMENTATION; MANOMETRY; METHODOLOGY; MIDDLE AGED; MONITOR; MONITORING; OSCILLOMETRY; SENSITIVITY AND SPECIFICITY;

EID: 23244438772     PISSN: 10903127     EISSN: 15450066     Source Type: Journal    
DOI: 10.1080/10903120590891958     Document Type: Article
Times cited : (8)

References (16)
  • 2
    • 0347359323 scopus 로고    scopus 로고
    • Nontraumatic out-of-hospital hypotension predicts inhospital mortality
    • Jones AE, Stiell IG, Nesbitt LP, et al. Nontraumatic out-of-hospital hypotension predicts inhospital mortality. Ann Emerg Med. 2004;43:106-13.
    • (2004) Ann Emerg Med , vol.43 , pp. 106-113
    • Jones, A.E.1    Stiell, I.G.2    Nesbitt, L.P.3
  • 3
    • 0036859196 scopus 로고    scopus 로고
    • Damage control: Past, present, and future of prehospital stroke management
    • Sayre MR. Damage control: past, present, and future of prehospital stroke management. Emerg Med Clin North Am. 2002;20:877-86.
    • (2002) Emerg Med Clin North Am , vol.20 , pp. 877-886
    • Sayre, M.R.1
  • 4
    • 27844469613 scopus 로고    scopus 로고
    • Management of suspected aortic dissection during interfacility transport: Opportunity for beneficial intervention by the critical care transport crew
    • Thomas SH, Winsor G, Biddinger P, Wedel SK. Management of suspected aortic dissection during interfacility transport: Opportunity for beneficial intervention by the critical care transport crew, [abstract] Chest 2003;124:181S-2S.
    • (2003) Chest , vol.124
    • Thomas, S.H.1    Winsor, G.2    Biddinger, P.3    Wedel, S.K.4
  • 5
    • 0034201021 scopus 로고    scopus 로고
    • Resuscitation of blood pressure and oxygenation
    • Brain Trauma Foundation, American Association of Neurological Surgeons, Joint Section on Neurotrauma and Critical Care. Resuscitation of blood pressure and oxygenation. J Neurotrauma. 2000;17:471-8.
    • (2000) J Neurotrauma , vol.17 , pp. 471-478
  • 6
    • 0345425649 scopus 로고    scopus 로고
    • A new non-invasive method to measure blood pressure
    • Belani K, Ozaki M, Hynson J. A new non-invasive method to measure blood pressure. Anesthesiology. 1999;91:686-92.
    • (1999) Anesthesiology , vol.91 , pp. 686-692
    • Belani, K.1    Ozaki, M.2    Hynson, J.3
  • 7
    • 0032971217 scopus 로고    scopus 로고
    • Accuracy of radial artery blood pressure determination with the Vasotrac
    • Belani KG, Buckley JJ, Poliac MO. Accuracy of radial artery blood pressure determination with the Vasotrac. Can J Anaesth. 1999;46:488-96.
    • (1999) Can J Anaesth , vol.46 , pp. 488-496
    • Belani, K.G.1    Buckley, J.J.2    Poliac, M.O.3
  • 8
    • 7444226252 scopus 로고    scopus 로고
    • Use of a radial artery compression device for noninvasive, near-continuous blood pressure monitoring in the ED
    • Thomas SH, Winsor G, Pang PS, Driscoll K, Parry BA. Use of a radial artery compression device for noninvasive, near-continuous blood pressure monitoring in the ED. Am J Emerg Med. 2004;22:474-8.
    • (2004) Am J Emerg Med , vol.22 , pp. 474-478
    • Thomas, S.H.1    Winsor, G.2    Pang, P.S.3    Driscoll, K.4    Parry, B.A.5
  • 9
    • 0031951612 scopus 로고    scopus 로고
    • Indications and complications of arterial catheter use in surgical or medical intensive care units: Analysis of 4932 patients
    • Frezza EE, Mezghebe H. Indications and complications of arterial catheter use in surgical or medical intensive care units: analysis of 4932 patients. Am Surg. 1998;64:127-31.
    • (1998) Am Surg , vol.64 , pp. 127-131
    • Frezza, E.E.1    Mezghebe, H.2
  • 10
    • 0004551137 scopus 로고    scopus 로고
    • Comparing several methods of measuring the same quantity
    • Seed P. Comparing several methods of measuring the same quantity. Stata Technical Bull. 2000;55:2-9.
    • (2000) Stata Technical Bull , vol.55 , pp. 2-9
    • Seed, P.1
  • 11
    • 0032908255 scopus 로고    scopus 로고
    • Practice parameters for hemodynamic support of sepsis in adult patients in sepsis
    • Anonymous. Practice parameters for hemodynamic support of sepsis in adult patients in sepsis. Crit Care Med. 1999;27:639-60.
    • (1999) Crit Care Med , vol.27 , pp. 639-660
  • 12
    • 0025483032 scopus 로고
    • The accuracy of rapid oscillometric blood pressure determination
    • Gorback MS, Quill TJ, Graubert DA. The accuracy of rapid oscillometric blood pressure determination. Biomed Instrum Technol. 1990;24:371-4.
    • (1990) Biomed Instrum Technol , vol.24 , pp. 371-374
    • Gorback, M.S.1    Quill, T.J.2    Graubert, D.A.3
  • 13
    • 0029831681 scopus 로고    scopus 로고
    • Review: A century of confusion; which bladder for accurate blood pressure measurement?
    • O'Brien E. Review: a century of confusion; which bladder for accurate blood pressure measurement? J Hum Hypertens. 1996;10:565-72.
    • (1996) J Hum Hypertens , vol.10 , pp. 565-572
    • O'Brien, E.1
  • 15
    • 0019796884 scopus 로고
    • Ulnar nerve palsy possibly related to use of automatically cycled blood pressure cuff
    • Sy WP. Ulnar nerve palsy possibly related to use of automatically cycled blood pressure cuff. Anesth Analg. 1981;60:687-8.
    • (1981) Anesth Analg , vol.60 , pp. 687-688
    • Sy, W.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.