메뉴 건너뛰기




Volumn 21, Issue 3, 2005, Pages 408-418

Development of infrared optical sensor for selective detection of tyrosine in biological fluids

Author keywords

Amino acids; Evanescent wave; FT IR; IR sensor; Tyrosine

Indexed keywords

ABSORPTION; AMINO ACIDS; COMPLEXATION; COPPER COMPOUNDS; INFRARED DEVICES; LIGHT REFLECTION; OPTICAL SENSORS; REGRESSION ANALYSIS; SOLUTIONS; SYNTHESIS (CHEMICAL);

EID: 23144455518     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.bios.2004.11.001     Document Type: Article
Times cited : (33)

References (43)
  • 1
    • 0038715558 scopus 로고    scopus 로고
    • Determination of tyrosine through a FIA-direct chemiluminescence procedure
    • S. Alonso, L. Zamora, and M. Calatayud Determination of tyrosine through a FIA-direct chemiluminescence procedure Talanta 60 2003 369 376
    • (2003) Talanta , vol.60 , pp. 369-376
    • Alonso, S.1    Zamora, L.2    Calatayud, M.3
  • 2
    • 0142028984 scopus 로고    scopus 로고
    • Analysis of tryptophan and tyrosine in cerebrospinal fluid by capillary electrophoresis and ball lens UV-pulsed laser-induced fluorescence detection
    • C. Bayle, N. Siri, V. Poinsot, M. Treilhou, E. Causse, and F. Couderc Analysis of tryptophan and tyrosine in cerebrospinal fluid by capillary electrophoresis and ball lens UV-pulsed laser-induced fluorescence detection J. Chromatogr. A 1013 2003 123 130
    • (2003) J. Chromatogr. a , vol.1013 , pp. 123-130
    • Bayle, C.1    Siri, N.2    Poinsot, V.3    Treilhou, M.4    Causse, E.5    Couderc, F.6
  • 3
    • 0037420705 scopus 로고    scopus 로고
    • Simultaneous measurement of phenylalanine and tyrosine in phenylketonuric plasma and dried blood by high-performance liquid chromatography
    • Y. Dale, V. Mackey, R. Mushi, A. Nyanda, M. Maleque, and J. Ike Simultaneous measurement of phenylalanine and tyrosine in phenylketonuric plasma and dried blood by high-performance liquid chromatography J. Chromatogr. B. 788 2003 1 8
    • (2003) J. Chromatogr. B. , vol.788 , pp. 1-8
    • Dale, Y.1    MacKey, V.2    Mushi, R.3    Nyanda, A.4    Maleque, M.5    Ike, J.6
  • 5
    • 37049126956 scopus 로고
    • Ligand chromatography on asymmetric complex-forming sorbents as a new method for resolution of racemates
    • V.A. Davankov, and S.V. Rogozhin Ligand chromatography on asymmetric complex-forming sorbents as a new method for resolution of racemates Chem. Commun. 10 1971 490
    • (1971) Chem. Commun. , vol.10 , pp. 490
    • Davankov, V.A.1    Rogozhin, S.V.2
  • 6
    • 33544461402 scopus 로고
    • Ligand chromatography as a novel method for the investigation of mixed complexes: Stereoselective effects in α-amino acid copper(II) complexes
    • V.A. Davankov, and A.V. Rogozhin Ligand chromatography as a novel method for the investigation of mixed complexes: stereoselective effects in α-amino acid copper(II) complexes J. Chromatogr. 60 1971 212 284
    • (1971) J. Chromatogr. , vol.60 , pp. 212-284
    • Davankov, V.A.1    Rogozhin, A.V.2
  • 8
    • 0037175431 scopus 로고    scopus 로고
    • Gas chromatography-mass spectrometry method for determination of phenylalanine and tyrosine in neonatal blood spots
    • C. Deng, Y. Deng, B. Wang, and X. Yang Gas chromatography-mass spectrometry method for determination of phenylalanine and tyrosine in neonatal blood spots J. Chromatogr. B 780 2002 407 413
    • (2002) J. Chromatogr. B , vol.780 , pp. 407-413
    • Deng, C.1    Deng, Y.2    Wang, B.3    Yang, X.4
  • 9
    • 0030949876 scopus 로고    scopus 로고
    • Determination of p-hydroxyphenylpyruvate, p-hydroxyphenyllactate and tyrosine in normal human plasma by gas chromatography-mass spectrometry isotope-dilution assay
    • J.C. Deutsch Determination of p-hydroxyphenylpyruvate, p-hydroxyphenyllactate and tyrosine in normal human plasma by gas chromatography-mass spectrometry isotope-dilution assay J. Chromatogr. B 690 1997 1 6
    • (1997) J. Chromatogr. B , vol.690 , pp. 1-6
    • Deutsch, J.C.1
  • 10
    • 0001053673 scopus 로고
    • Polymer-coated tapered cylindrical ATR elements for sensitive detection of organic solutes in water
    • M.C. Ertan-Lamontagne, S.R. Lowry, W.R. Seitz, and S.A. Tomellini Polymer-coated tapered cylindrical ATR elements for sensitive detection of organic solutes in water Appl. Spectrosc. 49 1995 1170 1173
    • (1995) Appl. Spectrosc. , vol.49 , pp. 1170-1173
    • Ertan-Lamontagne, M.C.1    Lowry, S.R.2    Seitz, W.R.3    Tomellini, S.A.4
  • 11
    • 0034617374 scopus 로고    scopus 로고
    • Precise analysis of primary amino acids in urine by an automated high-performance liquid chromatography method: Comparison with ion-exchange chromatography
    • D. Fekkes, A. Voskuilen-Kooyman, R. Jankie, and J. Huijmans Precise analysis of primary amino acids in urine by an automated high-performance liquid chromatography method: comparison with ion-exchange chromatography J. Chromatogr. B 744 2000 183 188
    • (2000) J. Chromatogr. B , vol.744 , pp. 183-188
    • Fekkes, D.1    Voskuilen-Kooyman, A.2    Jankie, R.3    Huijmans, J.4
  • 13
    • 0000603923 scopus 로고
    • Investigation of different polymers as coating materials for IR/ATR spectroscopic trace analysis of chlorinated hydrocarbons in water
    • R. Gobel, R. Krska, R. Kellner, W.R. Seitz, and S.A. Tomellini Investigation of different polymers as coating materials for IR/ATR spectroscopic trace analysis of chlorinated hydrocarbons in water Appl. Spectrosc. 48 1994 678 683
    • (1994) Appl. Spectrosc. , vol.48 , pp. 678-683
    • Gobel, R.1    Krska, R.2    Kellner, R.3    Seitz, W.R.4    Tomellini, S.A.5
  • 17
    • 0016531386 scopus 로고
    • New spectrophotometric method for simultaneous determination of tryptophan and tyrosine
    • S. Hassan New spectrophotometric method for simultaneous determination of tryptophan and tyrosine Anal. Chem. 47 8 1975 1429 1432
    • (1975) Anal. Chem. , vol.47 , Issue.8 , pp. 1429-1432
    • Hassan, S.1
  • 18
    • 0035960677 scopus 로고    scopus 로고
    • Endothelial dysfunction, oxidative stress, and risk of cardiovascular events in patients with coronary artery disease
    • T. Heitzer, T. Schlinzig, K. Krohn, T. Meinertz, and T. Munzel Endothelial dysfunction, oxidative stress, and risk of cardiovascular events in patients with coronary artery disease Circulation 104 2001 2673 2678
    • (2001) Circulation , vol.104 , pp. 2673-2678
    • Heitzer, T.1    Schlinzig, T.2    Krohn, K.3    Meinertz, T.4    Munzel, T.5
  • 19
    • 0000967984 scopus 로고    scopus 로고
    • Remote fiber-optic chemical sensing using evanescent-wave interactions in chalcogenide glass fibers
    • J. Heo, M. Rodrigues, S. Saggese, and G.H. Sigel Jr. Remote fiber-optic chemical sensing using evanescent-wave interactions in chalcogenide glass fibers Appl. Optics 30 1997 3944 3951
    • (1997) Appl. Optics , vol.30 , pp. 3944-3951
    • Heo, J.1    Rodrigues, M.2    Saggese, S.3    Sigel Jr., G.H.4
  • 20
    • 0038630390 scopus 로고    scopus 로고
    • Selective detection of copper ions in aqueous solution based on an evanescent wave infrared absorption spectroscopic method
    • G. Huang, and J. Yang Selective detection of copper ions in aqueous solution based on an evanescent wave infrared absorption spectroscopic method Anal. Chem. 75 2003 2262 2269
    • (2003) Anal. Chem. , vol.75 , pp. 2262-2269
    • Huang, G.1    Yang, J.2
  • 21
    • 0032014756 scopus 로고    scopus 로고
    • Determination of l-phenylalanine based on an NADH-detecting biosensor
    • T. Huang, A. Warsinke, T. Kuwana, and F.W. Scheller Determination of l-phenylalanine based on an NADH-detecting biosensor Anal. Chem. 70 1998 991 997
    • (1998) Anal. Chem. , vol.70 , pp. 991-997
    • Huang, T.1    Warsinke, A.2    Kuwana, T.3    Scheller, F.W.4
  • 22
    • 0029129972 scopus 로고
    • Reactive species in ischemic rat lung injury: Contribution of peroxynitrite
    • H. Ischiropoulos, A.B. al-Mehdi, and A.B. Fisher Reactive species in ischemic rat lung injury: contribution of peroxynitrite Am. J. Physiol. 269 1995 L158 L164
    • (1995) Am. J. Physiol. , vol.269
    • Ischiropoulos, H.1    Al-Mehdi, A.B.2    Fisher, A.B.3
  • 23
    • 0024731130 scopus 로고
    • Multivariate calibration for assays in clinical chemistry using attenuated total reflection infrared spectra of human blood plasma
    • G. Janatsch, J.D. Kruse-Jarres, R. Marbach, and H.M. Heise Multivariate calibration for assays in clinical chemistry using attenuated total reflection infrared spectra of human blood plasma Anal. Chem. 61 1989 2016 2023
    • (1989) Anal. Chem. , vol.61 , pp. 2016-2023
    • Janatsch, G.1    Kruse-Jarres, J.D.2    Marbach, R.3    Heise, H.M.4
  • 24
    • 36449004516 scopus 로고
    • Fiber optic sensor for chlorinated hydrocarbons in water based on infrared fibers and tunable diode laser
    • R. Krska, R. Kellner, U. Schiessel, M. Tacke, and A. Katzir Fiber optic sensor for chlorinated hydrocarbons in water based on infrared fibers and tunable diode laser Appl. Phys. Lett. 63 1993 1868 1870
    • (1993) Appl. Phys. Lett. , vol.63 , pp. 1868-1870
    • Krska, R.1    Kellner, R.2    Schiessel, U.3    Tacke, M.4    Katzir, A.5
  • 25
    • 0018741465 scopus 로고
    • Use of native fluorescence measurements and stopped-flow scanning technique in the high-performance liquid chromatographic analysis of catecholamines and related compounds
    • A.M. Krstulovic, and A.M. Powell Use of native fluorescence measurements and stopped-flow scanning technique in the high-performance liquid chromatographic analysis of catecholamines and related compounds J. Chromatogr. 171 1979 345 356
    • (1979) J. Chromatogr. , vol.171 , pp. 345-356
    • Krstulovic, A.M.1    Powell, A.M.2
  • 26
    • 0037435899 scopus 로고    scopus 로고
    • New approach to the simultaneous analysis of catecholamines and tyrosines in biological fluids
    • P. Kumarathasan, and R. Vincent New approach to the simultaneous analysis of catecholamines and tyrosines in biological fluids J. Chromatogr. A 987 2003 349 358
    • (2003) J. Chromatogr. a , vol.987 , pp. 349-358
    • Kumarathasan, P.1    Vincent, R.2
  • 29
    • 0024321419 scopus 로고
    • Determination of branched-chain amino acids and tyrosine in serum of patients with various hepatic diseases, and its clinical usefulness
    • Y. Mazuma, M. Maekawa, Y. Kuwabara, T. Nakajima, K. Taniguchi, and T. Kanno Determination of branched-chain amino acids and tyrosine in serum of patients with various hepatic diseases, and its clinical usefulness Clin. Chem. 35 1989 1399 1403
    • (1989) Clin. Chem. , vol.35 , pp. 1399-1403
    • Mazuma, Y.1    Maekawa, M.2    Kuwabara, Y.3    Nakajima, T.4    Taniguchi, K.5    Kanno, T.6
  • 32
    • 0026063664 scopus 로고
    • Differential-pulse adsorptive stripping voltammetric determination of tyrosine and histidine at a hanging mercury drop electrode after coupling with diazotized sulphanilic acid
    • J.C. Moreira, and A.G. Fogg Differential-pulse adsorptive stripping voltammetric determination of tyrosine and histidine at a hanging mercury drop electrode after coupling with diazotized sulphanilic acid Analyst 116 1991 249 252
    • (1991) Analyst , vol.116 , pp. 249-252
    • Moreira, J.C.1    Fogg, A.G.2
  • 33
    • 0032617668 scopus 로고    scopus 로고
    • Oxidative stress and neuroprotection in Parkinson's disease: Implications from studies on dopamine-induced apoptosis
    • D. Offen, A. Hochmaan, S. Gorodin, I. Ziv, A. Shirvan, A. Barzilai, and E. Melamed Oxidative stress and neuroprotection in Parkinson's disease: implications from studies on dopamine-induced apoptosis Adv. Neurol. 80 1999 265 269
    • (1999) Adv. Neurol. , vol.80 , pp. 265-269
    • Offen, D.1    Hochmaan, A.2    Gorodin, S.3    Ziv, I.4    Shirvan, A.5    Barzilai, A.6    Melamed, E.7
  • 34
    • 0344241149 scopus 로고    scopus 로고
    • In situ FTIR studies on the electrochemical oxidation of histidine and tyrosine
    • K. Ogura, M. Kobayashi, M. Nakayama, and Y. Miho In situ FTIR studies on the electrochemical oxidation of histidine and tyrosine J. Electroanal. Chem. 463 1999 218 223
    • (1999) J. Electroanal. Chem. , vol.463 , pp. 218-223
    • Ogura, K.1    Kobayashi, M.2    Nakayama, M.3    Miho, Y.4
  • 35
    • 0345096597 scopus 로고    scopus 로고
    • Simultaneous determination of tyrosine, phenylalanine and deoxyguanosine oxidation products by liquid chromatography-tandem mass spectrometry as non-invasive biomarkers for oxidative damage
    • H. Orhan, N. Vermeulen, C. Tump, H. Zappey, and J. Meerman Simultaneous determination of tyrosine, phenylalanine and deoxyguanosine oxidation products by liquid chromatography-tandem mass spectrometry as non-invasive biomarkers for oxidative damage J. Chromatogr. B 799 2004 245 254
    • (2004) J. Chromatogr. B , vol.799 , pp. 245-254
    • Orhan, H.1    Vermeulen, N.2    Tump, C.3    Zappey, H.4    Meerman, J.5
  • 36
    • 0019557155 scopus 로고
    • Liquid chromatographic determination of creatinine in serum and urine
    • C.P. Patel, and R.C. George Liquid chromatographic determination of creatinine in serum and urine Anal. Chem. 53 4 1981 734 735
    • (1981) Anal. Chem. , vol.53 , Issue.4 , pp. 734-735
    • Patel, C.P.1    George, R.C.2
  • 37
    • 0000163844 scopus 로고
    • Indirect electrochemical determination of l-tyrosine using mushroom tyrosinase in solution
    • G.A. Rivas, and V.M. Solis Indirect electrochemical determination of l-tyrosine using mushroom tyrosinase in solution Anal. Chem. 63 1991 2762 2765
    • (1991) Anal. Chem. , vol.63 , pp. 2762-2765
    • Rivas, G.A.1    Solis, V.M.2
  • 39
    • 0030023467 scopus 로고    scopus 로고
    • Isocratic high-performance liquid chromatographic method for quantitative determination of lysine, histidine and tyrosine in foods
    • M.A. Sanz, G. Castillo, and A. Hernandez Isocratic high-performance liquid chromatographic method for quantitative determination of lysine, histidine and tyrosine in foods J. Chromatogr. A 719 1996 195 201
    • (1996) J. Chromatogr. a , vol.719 , pp. 195-201
    • Sanz, M.A.1    Castillo, G.2    Hernandez, A.3
  • 40
    • 0032768070 scopus 로고    scopus 로고
    • Sensitivity of electrospray-tandem mass spectrometry using the phenylalanine/tyrosine-ratio for differential diagnosis of hyperphenylalaninemia in neonates
    • A. Schulze, D. Kohlmueller, and E. Mayatepek Sensitivity of electrospray-tandem mass spectrometry using the phenylalanine/tyrosine-ratio for differential diagnosis of hyperphenylalaninemia in neonates Clin. Chin. Acta 283 1999 15 20
    • (1999) Clin. Chin. Acta , vol.283 , pp. 15-20
    • Schulze, A.1    Kohlmueller, D.2    Mayatepek, E.3
  • 43
    • 0022473886 scopus 로고
    • Resolution of the clinical features of tyrosinemia following orthotopic liver transplantation for hepatoma
    • D.H. Van Thiel, L.M. Gartner, and F.K. Thorp Resolution of the clinical features of tyrosinemia following orthotopic liver transplantation for hepatoma J. Hepatol. 3 1 1986 42 48
    • (1986) J. Hepatol. , vol.3 , Issue.1 , pp. 42-48
    • Van Thiel, D.H.1    Gartner, L.M.2    Thorp, F.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.