메뉴 건너뛰기




Volumn 14, Issue 1, 2001, Pages 1-6

Extraction resistance of 2.7 mm medio-lateral-placed cortical screws compared with 2.7 mm and 3.5 mm cranio-caudal-placed cortical screws in canine cadaver radii

Author keywords

Canine; Cortical screws; Extraction; Placement

Indexed keywords


EID: 23044524122     PISSN: 09320814     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-0038-1632665     Document Type: Article
Times cited : (6)

References (17)
  • 2
    • 3042932688 scopus 로고
    • External skeletal fixation using the through-and-through Kirshner-Ehmer splint
    • Bradley RL, Rouse GP. External skeletal fixation using the through-and-through Kirshner-Ehmer splint. J Am Anim Hosp Assoc 1980; 16:523.
    • (1980) J Am Anim Hosp Assoc , vol.16 , pp. 523
    • Bradley, R.L.1    Rouse, G.P.2
  • 5
    • 0002081049 scopus 로고
    • Fractures of the radius and ulna
    • Slatter DH (ed). Philadelphia: WB Saunders
    • Egger EL. Fractures of the radius and ulna. In: Textbook of Small Animal Surgery, 2nd Edn. Slatter DH (ed). Philadelphia: WB Saunders 1993; 1736.
    • (1993) Textbook of Small Animal Surgery, 2nd Edn. , pp. 1736
    • Egger, E.L.1
  • 6
    • 0030131156 scopus 로고    scopus 로고
    • Sample size estimates for the use of human bone in the experimental study of cancellous screw extraction mechanics
    • Hearn TC, Szalai JP, Surowiak JF, and Schatzker J. Sample size estimates for the use of human bone in the experimental study of cancellous screw extraction mechanics. J Biomechanics 1996; 29: 569-72.
    • (1996) J Biomechanics , vol.29 , pp. 569-572
    • Hearn, T.C.1    Szalai, J.P.2    Surowiak, J.F.3    Schatzker, J.4
  • 7
    • 0029315721 scopus 로고
    • Effects of temperature and storage time on pin pull-out testing in harvested canine femurs
    • Huss BT, Anderson MA, Wagner-Mann CC, Payne JT. Effects of temperature and storage time on pin pull-out testing in harvested canine femurs. Am J Vet Res 1995; 56: 715-9.
    • (1995) Am J Vet Res , vol.56 , pp. 715-719
    • Huss, B.T.1    Anderson, M.A.2    Wagner-Mann, C.C.3    Payne, J.T.4
  • 8
    • 0024729886 scopus 로고
    • Radial and tibial fracture repair with external skeletal fixation: Effects of fracture type, reduction, and complications on healing
    • Johnson AL, Kneller SK, Weigel RM. Radial and tibial fracture repair with external skeletal fixation: Effects of fracture type, reduction, and complications on healing. Vet Surg 1989; 18: 367.
    • (1989) Vet Surg , vol.18 , pp. 367
    • Johnson, A.L.1    Kneller, S.K.2    Weigel, R.M.3
  • 11
    • 0018634392 scopus 로고
    • A survey of bone fractures in the dog and cat
    • Phillips IR. A survey of bone fractures in the dog and cat. J Small Anim Pract 1979; 20: 661.
    • (1979) J Small Anim Pract , vol.20 , pp. 661
    • Phillips, I.R.1
  • 13
    • 0031093742 scopus 로고    scopus 로고
    • Use of a medial bone plate for repair of radius and ulna fractures in dogs and cats: A report of 22 cases
    • Sardinas JC, Montavon PM. Use of a medial bone plate for repair of radius and ulna fractures in dogs and cats: A report of 22 cases. Vet Surgery 1997; 26: 108-13.
    • (1997) Vet Surgery , vol.26 , pp. 108-113
    • Sardinas, J.C.1    Montavon, P.M.2
  • 14
    • 0043120915 scopus 로고
    • Bone plating for radial fractures in small dogs
    • Sumner-Smith G. Bone plating for radial fractures in small dogs. Mod Vet Pract 1970; 3: 30.
    • (1970) Mod Vet Pract , vol.3 , pp. 30
    • Sumner-Smith, G.1
  • 16
    • 0019490733 scopus 로고
    • In vitro evaluation of the loosening characteristics of self-tapped and non-self-tapped cortical bone screws
    • Vangsness CT, Carter DR, and Frankel VH, In vitro evaluation of the loosening characteristics of self-tapped and non-self-tapped cortical bone screws. Clinical Orthopaedics and Related Research 1981; 157: 279-86.
    • (1981) Clinical Orthopaedics and Related Research , vol.157 , pp. 279-286
    • Vangsness, C.T.1    Carter, D.R.2    Frankel, V.H.3
  • 17
    • 0026831385 scopus 로고
    • Mechanical evaluation of three methods of plating distal radial osteotomies
    • Wallace MK, Boudrieau RJ, Hyodo K, Torzilli PS. Mechanical evaluation of three methods of plating distal radial osteotomies. Vet Surg 1992; 21: 99-106.
    • (1992) Vet Surg , vol.21 , pp. 99-106
    • Wallace, M.K.1    Boudrieau, R.J.2    Hyodo, K.3    Torzilli, P.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.