메뉴 건너뛰기




Volumn 20, Issue 5, 2005, Pages 652-657

Cementation of a metal-inlay polyethylene liner into a stable metal shell in revision total hip arthroplasty

Author keywords

Metal inlay polyethylene liner; Revision total hip arthroplasty; Stable acetabular shell

Indexed keywords

BIOMATERIAL; METAL; POLYETHYLENE;

EID: 23044507495     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arth.2005.01.019     Document Type: Article
Times cited : (26)

References (24)
  • 1
    • 0028243267 scopus 로고
    • Catastrophic failure of the polyethylene liner of uncemented acetabular component
    • D.J. Berry, C.L. Bames, and R.D. Scott Catastrophic failure of the polyethylene liner of uncemented acetabular component J Bone Joint Surg Br 76 1994 575
    • (1994) J Bone Joint Surg Br , vol.76 , pp. 575
    • Berry, D.J.1    Bames, C.L.2    Scott, R.D.3
  • 2
    • 0031925520 scopus 로고    scopus 로고
    • Technique for acetabular liner revision in a nonmodular metal-backed component
    • D.M. LaPorte, M.A. Mont, and H. Pierre-Jacques Technique for acetabular liner revision in a nonmodular metal-backed component J Arthroplasty 13 1998 348
    • (1998) J Arthroplasty , vol.13 , pp. 348
    • Laporte, D.M.1    Mont, M.A.2    Pierre-Jacques, H.3
  • 3
    • 0030721981 scopus 로고    scopus 로고
    • Treatment of pelvic osteolysis associated with a stable acetabular component inserted without cement as part of a total hip replacement
    • W.J. Maloney, P. Herzwurm, and W. Paprosky Treatment of pelvic osteolysis associated with a stable acetabular component inserted without cement as part of a total hip replacement J Bone Joint Surg Am 79 1997 1628
    • (1997) J Bone Joint Surg Am , vol.79 , pp. 1628
    • Maloney, W.J.1    Herzwurm, P.2    Paprosky, W.3
  • 4
    • 0036713083 scopus 로고    scopus 로고
    • Polyethylene liner exchange for excessive wear and osteolysis
    • K.M. Terefenko, C.J. Sychterz, and K. Orishimo Polyethylene liner exchange for excessive wear and osteolysis J Arthroplasty 17 2002 198
    • (2002) J Arthroplasty , vol.17 , pp. 198
    • Terefenko, K.M.1    Sychterz, C.J.2    Orishimo, K.3
  • 5
    • 0027508115 scopus 로고
    • Dissociation of a polyethylene liner from an acetabular cup
    • H.U. Cameron Dissociation of a polyethylene liner from an acetabular cup Orthop Rev 22 1993 1160
    • (1993) Orthop Rev , vol.22 , pp. 1160
    • Cameron, H.U.1
  • 6
    • 0035074842 scopus 로고    scopus 로고
    • Dislodgment of polyethylene liners in first and second-generation Harris-Galante acetabular components. a report of eighteen cases
    • A. Gonzalez Della Valle, P.S. Ruzo, and S. Li Dislodgment of polyethylene liners in first and second-generation Harris-Galante acetabular components. A report of eighteen cases J Bone Joint Surg Am 83 2001 553
    • (2001) J Bone Joint Surg Am , vol.83 , pp. 553
    • Gonzalez Della Valle, A.1    Ruzo, P.S.2    Li, S.3
  • 7
    • 0035035769 scopus 로고    scopus 로고
    • Polyethylene liner dissociation with the Harris-Galante II acetabular component
    • W.M. Mihalko, and T. Papademetriou Polyethylene liner dissociation with the Harris-Galante II acetabular component Clin Orthop 386 2001 166
    • (2001) Clin Orthop , vol.386 , pp. 166
    • Mihalko, W.M.1    Papademetriou, T.2
  • 8
    • 0036083640 scopus 로고    scopus 로고
    • Locking mechanism failure in the Harris-Galante porous acetabular component associated with recurrent hip dislocation
    • C.L. Peters, and CL. Sullivan Locking mechanism failure in the Harris-Galante porous acetabular component associated with recurrent hip dislocation J Arthroplasty 17 2002 507
    • (2002) J Arthroplasty , vol.17 , pp. 507
    • Peters, C.L.1    Sullivan, C.L.2
  • 9
    • 0036155810 scopus 로고    scopus 로고
    • Polyethylene liner dissociation in Harris-Galante acetabular components: A report of 7 cases
    • J. Werle, S. Goodman, and D. Shurman Polyethylene liner dissociation in Harris-Galante acetabular components: a report of 7 cases J Arthroplasty 17 2002 78
    • (2002) J Arthroplasty , vol.17 , pp. 78
    • Werle, J.1    Goodman, S.2    Shurman, D.3
  • 11
    • 0036676715 scopus 로고    scopus 로고
    • Dislocation of the polyethylene liner in hip arthroplasty. 6 patients with dislocation within 3 years
    • O. Niggemeyer, B. Fink, and W. Ruther Dislocation of the polyethylene liner in hip arthroplasty. 6 patients with dislocation within 3 years Acta Orthop Scand 73 2002 403
    • (2002) Acta Orthop Scand , vol.73 , pp. 403
    • Niggemeyer, O.1    Fink, B.2    Ruther, W.3
  • 13
    • 0033957831 scopus 로고    scopus 로고
    • Factors contributing to rapid wear and osteolysis in hips with modular acetabular bearing made of Hylamer
    • D.L. Scott, P.A. Campbell, and C.D. McClung Factors contributing to rapid wear and osteolysis in hips with modular acetabular bearing made of Hylamer J Arthroplasty 15 2000 35
    • (2000) J Arthroplasty , vol.15 , pp. 35
    • Scott, D.L.1    Campbell, P.A.2    McClung, C.D.3
  • 15
    • 0023038892 scopus 로고
    • In vivo construction of a metal-backed, high-molecular-weight polyethylene cup during McKee-Farrar revision total joint arthroplasty
    • D.A. Heck, and D.G. Murray In vivo construction of a metal-backed, high-molecular-weight polyethylene cup during McKee-Farrar revision total joint arthroplasty J Arthroplasty 1 1986 203
    • (1986) J Arthroplasty , vol.1 , pp. 203
    • Heck, D.A.1    Murray, D.G.2
  • 16
    • 0014525462 scopus 로고
    • Traumatic arthritis of hip after dislocation and acetabular fractures. Treatment by mold arthroplasty. An end result study using a new method of result evaluation
    • W.H. Harris Traumatic arthritis of hip after dislocation and acetabular fractures. Treatment by mold arthroplasty. An end result study using a new method of result evaluation J Bone Joint Surg Am 51 1969 737
    • (1969) J Bone Joint Surg Am , vol.51 , pp. 737
    • Harris, W.H.1
  • 17
    • 0036086080 scopus 로고    scopus 로고
    • Polyethylene liner cementation into fixed acetabular shells
    • G.F. Haft, A.D. Heiner, and J.J. Callaham Polyethylene liner cementation into fixed acetabular shells J Arthroplasty 17 4 Suppl. 1 2002 167
    • (2002) J Arthroplasty , vol.17 , Issue.4 SUPPL. 1 , pp. 167
    • Haft, G.F.1    Heiner, A.D.2    Callaham, J.J.3
  • 19
    • 0033813366 scopus 로고    scopus 로고
    • Mechanical stability of polyethylene liners cemented into acetabular shells
    • C.V. Bensen, J. Del Shutte, and K.D. Weaver Mechanical stability of polyethylene liners cemented into acetabular shells Crit Rev Biomed Eng 28 2000 7
    • (2000) Crit Rev Biomed Eng , vol.28 , pp. 7
    • Bensen, C.V.1    Del Shutte, J.2    Weaver, K.D.3
  • 20
  • 21
    • 0034862928 scopus 로고    scopus 로고
    • The strength of a cement acetabular locking mechanism
    • R.D. Meldrum, and J.M. Hollis The strength of a cement acetabular locking mechanism J Arthroplasty 16 2001 748
    • (2001) J Arthroplasty , vol.16 , pp. 748
    • Meldrum, R.D.1    Hollis, J.M.2
  • 22
    • 0036714997 scopus 로고    scopus 로고
    • Cementation of a polyethylene liner into a metal shell: Factors related to mechanical stability
    • K.F. Bonner, R.E. Delanois, and G. Harbach Cementation of a polyethylene liner into a metal shell: factors related to mechanical stability J Bone Joint Surg Am 84 2002 1587
    • (2002) J Bone Joint Surg Am , vol.84 , pp. 1587
    • Bonner, K.F.1    Delanois, R.E.2    Harbach, G.3
  • 23
    • 0344062901 scopus 로고    scopus 로고
    • A biomechanical analysis of polyethylene liner cementation into a fixed metal acetabular shell
    • A.D. Heiner, G.F. Haft, and L.D. Dorr A biomechanical analysis of polyethylene liner cementation into a fixed metal acetabular shell Trans Orthop Res Soc 49 2003 1367
    • (2003) Trans Orthop Res Soc , vol.49 , pp. 1367
    • Heiner, A.D.1    Haft, G.F.2    Dorr, L.D.3
  • 24
    • 0344629805 scopus 로고    scopus 로고
    • Acetabular liner fixation by cement
    • W.A. Jiranek Acetabular liner fixation by cement Clin Orthop 417 2003 217
    • (2003) Clin Orthop , vol.417 , pp. 217
    • Jiranek, W.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.