A method of calculation for contact pressure between femoral head and cup of artificial hip joint

Author keywords

Biolubrication; Contact mechanics; Joints; Polymeric bearings; Spherical (pivot)

Indexed keywords

ELASTIC MODULI; FINITE ELEMENT METHOD; FRICTION; PRESSURE DISTRIBUTION; PRESSURE MEASUREMENT; SHEAR DEFORMATION; TORQUE MEASUREMENT; WEAR OF MATERIALS; DEFORMATION; PARAMETER ESTIMATION; PLASTIC PRODUCTS; TRIBOLOGY;

EID: 23044493484     PISSN: 10402004     EISSN: None     Source Type: Journal    
DOI: 10.1080/05698190590929071     Document Type: Article
Times cited : (9)

References (10)
  • 1
    • 0000224782 scopus 로고
    • "The Contact Stress Problem for an Elastic Sphere Indenting an Elastic Cavity"
    • Goodman, L. E. and Keer, L. M. (1965), "The Contact Stress Problem for an Elastic Sphere Indenting an Elastic Cavity," Int. J. Solid Structures, 1, pp 407-415.
    • (1965) Int. J. Solid Structures , vol.1 , pp. 407-415
    • Goodman, L.E.1    Keer, L.M.2
  • 2
    • 0022107624 scopus 로고
    • "The Effect of Conformity and Plastic Thickness on Contact Stresses in Metal-Backed Plastic Implants"
    • Bartel, D. L., Burstein, A. H., Toda, M. D. and Edwards, D. L. (1985), "The Effect of Conformity and Plastic Thickness on Contact Stresses in Metal-Backed Plastic Implants," ASME J. of Biomechanical Engineering, 107, pp 193-199.
    • (1985) ASME J. of Biomechanical Engineering , vol.107 , pp. 193-199
    • Bartel, D.L.1    Burstein, A.H.2    Toda, M.D.3    Edwards, D.L.4
  • 3
    • 0343554682 scopus 로고    scopus 로고
    • "A Comparison of Different Methods in Predicting Static Pressure Distribution in Articulating joints"
    • Li, G., Sakamoto, M. and Chao, E. Y. S. (1997), "A Comparison of Different Methods in Predicting Static Pressure Distribution in Articulating joints," Journal of Biomechanics, 30, 6, pp 635-638.
    • (1997) Journal of Biomechanics , vol.30 , Issue.6 , pp. 635-638
    • Li, G.1    Sakamoto, M.2    Chao, E.Y.S.3
  • 4
    • 0004278919 scopus 로고    scopus 로고
    • 4th ed., John Wiley & Sons, New York
    • Harris, T. A. (2001), Rolling Bearing Analysis, 4th ed., John Wiley & Sons, New York, pp 235-238.
    • (2001) Rolling Bearing Analysis , pp. 235-238
    • Harris, T.A.1
  • 7
    • 0001226143 scopus 로고
    • "Design Considerations for an Acetabular Component Made from an Enhanced form of Ultra High Molecular Weight Polyethylene"
    • Orthopaedic Research Society
    • Wright, T. M., Gunsallus, K. L., Rimnac, C. M., Bartel, D. L. and Klein, R. W. (1991), "Design Considerations for an Acetabular Component Made from an Enhanced form of Ultra High Molecular Weight Polyethylene," Proc. of the 37th Annual Meeting, Orthopaedic Research Society, 16, p 248.
    • (1991) Proc. of the 37th Annual Meeting , vol.16 , pp. 248
    • Wright, T.M.1    Gunsallus, K.L.2    Rimnac, C.M.3    Bartel, D.L.4    Klein, R.W.5
  • 8
    • 21244455926 scopus 로고
    • Morikita-Publisher, Tokyo, (in Japanese)
    • Kuroki, G. (1967), Strength of Materials, Morikita-Publisher, Tokyo, pp 187-189 (in Japanese).
    • (1967) Strength of Materials , pp. 187-189
    • Kuroki, G.1
  • 10
    • 0022108298 scopus 로고
    • "Laboratory Wear Tests and Clinical Observations of the Penetration of Femoral Heads into Acetabular Cups in Total Replacement Hip Joints III: The Measurement of Internal Volume Changes in Explanted Charnley Sockets After 2-16 Years in vivo and the Determination of Wear Factors"
    • Atkinson, J. R., Dowson, D., Isaac, J. H. and Wroblewski, B. M. (1985), "Laboratory Wear Tests and Clinical Observations of the Penetration of Femoral Heads into Acetabular Cups in Total Replacement Hip Joints III: The Measurement of Internal Volume Changes in Explanted Charnley Sockets After 2-16 Years in vivo and the Determination of Wear Factors," Wear, 104, pp 225-244.
    • (1985) Wear , vol.104 , pp. 225-244
    • Atkinson, J.R.1    Dowson, D.2    Isaac, J.H.3    Wroblewski, B.M.4