메뉴 건너뛰기




Volumn 96, Issue 3, 2005, Pages 453-456

Comparison of the five-electrode-derived EASI electrocardiogram to the mason likar electrocardiogram in the prehospital setting

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; ELECTROCARDIOGRAM; ELECTRODE; EMERGENCY HEALTH SERVICE; FEMALE; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; MALE; PATIENT; PRIORITY JOURNAL; QUESTIONNAIRE; THORAX PAIN;

EID: 23044444252     PISSN: 00029149     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.amjcard.2005.03.100     Document Type: Article
Times cited : (8)

References (12)
  • 1
    • 0026580444 scopus 로고
    • Evaluation of changes in standard electrocardiographic QRS waveforms recorded from activity-compatible proximal limb lead positions
    • O. Pahlm, W.K. Haisty, L. Edenbrandt, N.B. Wagner, D.C. Sevilla, R.H. Selvester, G.S. Wagner Evaluation of changes in standard electrocardiographic QRS waveforms recorded from activity-compatible proximal limb lead positions Am J Cardiol 69 1992 253 257
    • (1992) Am J Cardiol , vol.69 , pp. 253-257
    • Pahlm, O.1    Haisty, W.K.2    Edenbrandt, L.3    Wagner, N.B.4    Sevilla, D.C.5    Selvester, R.H.6    Wagner, G.S.7
  • 3
    • 0027942739 scopus 로고
    • Simultaneous ST-segment measurements using standard and monitoring-compatible torso limb lead placements at rest and during coronary occlusion
    • M.W. Krucoff, K.A. Loeffler, W.K. Haisty, J.E. Pope, S.T. Sawchak, G.S. Wagner, O. Pahlm Simultaneous ST-segment measurements using standard and monitoring-compatible torso limb lead placements at rest and during coronary occlusion Am J Cardiol 74 1994 997 1001
    • (1994) Am J Cardiol , vol.74 , pp. 997-1001
    • Krucoff, M.W.1    Loeffler, K.A.2    Haisty, W.K.3    Pope, J.E.4    Sawchak, S.T.5    Wagner, G.S.6    Pahlm, O.7
  • 4
    • 0018774802 scopus 로고
    • XYZ data interpreted by a 12-lead computer program using the derived electrocardiogram
    • G.E. Dower, H.B. Machado XYZ data interpreted by a 12-lead computer program using the derived electrocardiogram J Electrocardiol 12 1979 249 261
    • (1979) J Electrocardiol , vol.12 , pp. 249-261
    • Dower, G.E.1    MacHado, H.B.2
  • 5
    • 0036942544 scopus 로고    scopus 로고
    • Improved EASI coefficients, their derivation, values and performance
    • D.Q. Feild, C.L. Feldman, B.M. Horacek Improved EASI coefficients, their derivation, values and performance J Electrocardiol 35 suppl 2002 23 33
    • (2002) J Electrocardiol , vol.35 , Issue.SUPPL. , pp. 23-33
    • Feild, D.Q.1    Feldman, C.L.2    Horacek, B.M.3
  • 6
    • 0036938984 scopus 로고    scopus 로고
    • Comparability of 12-lead ECGs derived from EASI leads with standard 12-lead ECGs in the classification of acute myocardial ischemia and old myocardial infarction
    • P.M. Rautaharju, S.H. Zhou, E.W. Hancock, B.M. Hornacek, D.Q. Field, J.M. Lindauer, G.S. Wagner, O. Pahlm, C.L. Feldman Comparability of 12-lead ECGs derived from EASI leads with standard 12-lead ECGs in the classification of acute myocardial ischemia and old myocardial infarction J Electrocardiol 35 suppl 2002 35 40
    • (2002) J Electrocardiol , vol.35 , Issue.SUPPL. , pp. 35-40
    • Rautaharju, P.M.1    Zhou, S.H.2    Hancock, E.W.3    Hornacek, B.M.4    Field, D.Q.5    Lindauer, J.M.6    Wagner, G.S.7    Pahlm, O.8    Feldman, C.L.9
  • 7
    • 0037263128 scopus 로고    scopus 로고
    • Comparison of waveforms in conventional 12-lead ECGs and those derived from EASI leads in children
    • O. Pahlm, J. Pettersson, A. Thulin, C.L. Feldman, D.Q. Feild, G.S. Wagner Comparison of waveforms in conventional 12-lead ECGs and those derived from EASI leads in children J Electrocardiol 36 2003 25 31
    • (2003) J Electrocardiol , vol.36 , pp. 25-31
    • Pahlm, O.1    Pettersson, J.2    Thulin, A.3    Feldman, C.L.4    Feild, D.Q.5    Wagner, G.S.6
  • 8
    • 0026579840 scopus 로고
    • Comparison of a vectorcardio-graphically derived 12-lead electrocardiogram with the conventional electrocardiogram during wide QRS complex tachycardia, and its potential application for continuous bedside monitoring
    • B.J. Drew, M.M. Scheinman, G.T. Evans Jr Comparison of a vectorcardio-graphically derived 12-lead electrocardiogram with the conventional electrocardiogram during wide QRS complex tachycardia, and its potential application for continuous bedside monitoring Am J Cardiol 69 1992 612 618
    • (1992) Am J Cardiol , vol.69 , pp. 612-618
    • Drew, B.J.1    Scheinman, M.M.2    Evans Jr., G.T.3
  • 9
    • 0030903107 scopus 로고    scopus 로고
    • Comparison of standard and derived 12-lead electrocardiograms for diagnosis of coronary angioplasty-induced myocardial ischemia
    • B.J. Drew, M.G. Adams, M.M. Pelter, S.-F. Wung, M.A. Caldwell Comparison of standard and derived 12-lead electrocardiograms for diagnosis of coronary angioplasty-induced myocardial ischemia Am J Cardiol 78 1997 639 644
    • (1997) Am J Cardiol , vol.78 , pp. 639-644
    • Drew, B.J.1    Adams, M.G.2    Pelter, M.M.3    Wung, S.-F.4    Caldwell, M.A.5
  • 10
    • 0033389498 scopus 로고    scopus 로고
    • Accuracy of the EASI 12-lead electrocardiogram compared to the standard 12-lead cardiogram for diagnosing multiple cardiac abnormalities
    • B.J. Drew, M.M. Pelter, S.F. Wung, M.G. Adams, C. Taylor, G.T. Evans Jr, E. Foster Accuracy of the EASI 12-lead electrocardiogram compared to the standard 12-lead cardiogram for diagnosing multiple cardiac abnormalities J Electrocardiol 32 suppl 1999 38 47
    • (1999) J Electrocardiol , vol.32 , Issue.SUPPL. , pp. 38-47
    • Drew, B.J.1    Pelter, M.M.2    Wung, S.F.3    Adams, M.G.4    Taylor, C.5    Evans Jr., G.T.6    Foster, E.7
  • 11
    • 0034473818 scopus 로고    scopus 로고
    • Diagnostic accuracy of derived versus standard 12-lead electrocardiograms
    • B.M. Horacek, J.W. Warren, P. Stovicek, C.L. Feldman Diagnostic accuracy of derived versus standard 12-lead electrocardiograms J Electrocardiol 33 suppl 2000 155 160
    • (2000) J Electrocardiol , vol.33 , Issue.SUPPL. , pp. 155-160
    • Horacek, B.M.1    Warren, J.W.2    Stovicek, P.3    Feldman, C.L.4
  • 12
    • 0000273115 scopus 로고    scopus 로고
    • A vector based 5 electrode 12-lead ECG (EASI) is equivalent to conventional 12-lead ECG for diagnosis of myocardial infarction
    • G. Wehr, R. Peters, K. Khalife, A. Banning, V. Kuhlkamp, A. Rickards, R. Adams, R. Sechtem A vector based 5 electrode 12-lead ECG (EASI) is equivalent to conventional 12-lead ECG for diagnosis of myocardial infarction J Am Coll Cardiol 39 2002 122A
    • (2002) J Am Coll Cardiol , vol.39
    • Wehr, G.1    Peters, R.2    Khalife, K.3    Banning, A.4    Kuhlkamp, V.5    Rickards, A.6    Adams, R.7    Sechtem, R.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.