메뉴 건너뛰기




Volumn 30, Issue 4, 2005, Pages 516-521

Temperature change and hardness with different resin composites and photo-activation methods

Author keywords

[No Author keywords available]

Indexed keywords

FILTEK FLOW; FILTEK Z250; RESIN;

EID: 22944473280     PISSN: 03617734     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (15)

References (24)
  • 1
    • 0036832791 scopus 로고    scopus 로고
    • Shedding new light on composite polymerization
    • Caughman WF & Rueggeberg FA (2002) Shedding new light on composite polymerization Operative Dentistry 27(6) 636-638.
    • (2002) Operative Dentistry , vol.27 , Issue.6 , pp. 636-638
    • Caughman, W.F.1    Rueggeberg, F.A.2
  • 2
    • 0041491462 scopus 로고    scopus 로고
    • A comparative study of the properties of dental resin composites polymerized with plasma and halogen light
    • Deb S & Sehmi H (2003) A comparative study of the properties of dental resin composites polymerized with plasma and halogen light Dental Materials 19(6) 517-522.
    • (2003) Dental Materials , vol.19 , Issue.6 , pp. 517-522
    • Deb, S.1    Sehmi, H.2
  • 3
    • 0023297191 scopus 로고
    • A comparison of four modes of evaluating depth of cure of light-activated composites
    • DeWald JP & Ferracane JL (1987) A comparison of four modes of evaluating depth of cure of light-activated composites Journal of Dental Research 66(3) 727-730.
    • (1987) Journal of Dental Research , vol.66 , Issue.3 , pp. 727-730
    • DeWald, J.P.1    Ferracane, J.L.2
  • 4
    • 0022020982 scopus 로고
    • Correlation between hardness and degree of conversion during the setting reaction of unfilled dental restorative resins
    • Ferracane JL (1985) Correlation between hardness and degree of conversion during the setting reaction of unfilled dental restorative resins Dental Materials 16(1) 11-14.
    • (1985) Dental Materials , vol.16 , Issue.1 , pp. 11-14
    • Ferracane, J.L.1
  • 5
    • 0024693637 scopus 로고
    • Measurements of temperature generated by visible-light-cure lamps in an in vitro model
    • Goodis HE, White JM, Andrews J & Watanabe LG (1989) Measurements of temperature generated by visible-light-cure lamps in an in vitro model Dental Materials 5(4) 230-234.
    • (1989) Dental Materials , vol.5 , Issue.4 , pp. 230-234
    • Goodis, H.E.1    White, J.M.2    Andrews, J.3    Watanabe, L.G.4
  • 6
    • 0033165315 scopus 로고    scopus 로고
    • In-vitro pulp chamber temperature rise during composite resin polymerization with various light-curing sources
    • Hannig M & Bott B (1999) In-vitro pulp chamber temperature rise during composite resin polymerization with various light-curing sources Dental Materials 15(4) 275-281.
    • (1999) Dental Materials , vol.15 , Issue.4 , pp. 275-281
    • Hannig, M.1    Bott, B.2
  • 7
    • 84989552725 scopus 로고
    • Correlation between depth of cure and temperature rise of a light-activated resin
    • Hansen EK & Asmussen E (1993) Correlation between depth of cure and temperature rise of a light-activated resin Scandinavian Journal of Dental Research 101(3) 176-179.
    • (1993) Scandinavian Journal of Dental Research , vol.101 , Issue.3 , pp. 176-179
    • Hansen, E.K.1    Asmussen, E.2
  • 8
    • 0036886529 scopus 로고    scopus 로고
    • Effect of irradiation type (LED or QTH) on photo-activated composite shrinkage strain kinetics, temperature rise, and hardness
    • Hofmann N, Hugo B & Klaiber B (2002) Effect of irradiation type (LED or QTH) on photo-activated composite shrinkage strain kinetics, temperature rise, and hardness European Journal of Oral Sciences 110(6) 471-479.
    • (2002) European Journal of Oral Sciences , vol.110 , Issue.6 , pp. 471-479
    • Hofmann, N.1    Hugo, B.2    Klaiber, B.3
  • 9
    • 0035378990 scopus 로고    scopus 로고
    • Degree of conversion and temperature rise during polymerization of composite resin samples with blue diodes
    • Knezevic A, Tarle Z, Meniga A, Sutalo J, Pichler G & Ristic M (2001) Degree of conversion and temperature rise during polymerization of composite resin samples with blue diodes Journal of Oral Rehabilitation 28(6) 586-591.
    • (2001) Journal of Oral Rehabilitation , vol.28 , Issue.6 , pp. 586-591
    • Knezevic, A.1    Tarle, Z.2    Meniga, A.3    Sutalo, J.4    Pichler, G.5    Ristic, M.6
  • 10
    • 0013160499 scopus 로고
    • Thermal injury to normal dog teeth: In vivo measurements to pulp temperature increases and their effect on the pulp tissue
    • Lisanti VF & Zander HA (1952) Thermal injury to normal dog teeth: In vivo measurements to pulp temperature increases and their effect on the pulp tissue Journal of Dental Research 31(4) 548-558.
    • (1952) Journal of Dental Research , vol.31 , Issue.4 , pp. 548-558
    • Lisanti, V.F.1    Zander, H.A.2
  • 11
    • 0022760496 scopus 로고
    • Temperature rises produced by light sources and composites during curing
    • Lloyd CH, Joshi A & Mcglynn E (1986) Temperature rises produced by light sources and composites during curing Dental Materials 2(4) 170-174.
    • (1986) Dental Materials , vol.2 , Issue.4 , pp. 170-174
    • Lloyd, C.H.1    Joshi, A.2    Mcglynn, E.3
  • 12
    • 0035462154 scopus 로고    scopus 로고
    • Temperature transmission of High-output light-curing units through dentin
    • Loney RW & Price RBT (2001) Temperature transmission of High-output light-curing units through dentin Operative Dentistry 26(5) 516-520.
    • (2001) Operative Dentistry , vol.26 , Issue.5 , pp. 516-520
    • Loney, R.W.1    Price, R.B.T.2
  • 13
    • 0024065336 scopus 로고
    • Temperature rise during polymerization of visible light-activated composite resins
    • Masutami S, Setcos JC, Schinell RJ & Phillips RW (1988) Temperature rise during polymerization of visible light-activated composite resins Dental Materials 4(4) 174-178.
    • (1988) Dental Materials , vol.4 , Issue.4 , pp. 174-178
    • Masutami, S.1    Setcos, J.C.2    Schinell, R.J.3    Phillips, R.W.4
  • 14
    • 0022307545 scopus 로고
    • Cure performance of light-activated-composites by differential thermal analysis (DTA)
    • McCabe JF (1985) Cure performance of light-activated-composites by differential thermal analysis (DTA) Dental Materials 1(6) 231-234.
    • (1985) Dental Materials , vol.1 , Issue.6 , pp. 231-234
    • McCabe, J.F.1
  • 15
    • 0018863598 scopus 로고
    • The use of differential scanning calorimetry for the evaluation of dental materials
    • McCabe JF & Wilson HJ (1980) The use of differential scanning calorimetry for the evaluation of dental materials Journal of Oral Rehabilitation 7(3) 235-243.
    • (1980) Journal of Oral Rehabilitation , vol.7 , Issue.3 , pp. 235-243
    • McCabe, J.F.1    Wilson, H.J.2
  • 16
    • 22944432310 scopus 로고    scopus 로고
    • Spectral analysis of commercial LED dental curing lights
    • Abstract #507
    • Parr GR & Rueggeberg FA (2002) Spectral analysis of commercial LED dental curing lights Journal of Dental Research 81(Special Issue) Abstract #507 p 88.
    • (2002) Journal of Dental Research , vol.81 , Issue.SPEC. ISSUE , pp. 88
    • Parr, G.R.1    Rueggeberg, F.A.2
  • 17
    • 0034278146 scopus 로고    scopus 로고
    • Characterization of resin composites polymerized with plasma arc curing units
    • Peutzfeldt A, Sahafi A & Asmussen E (2000) Characterization of resin composites polymerized with plasma arc curing units Dental Materials 16(5) 330-336.
    • (2000) Dental Materials , vol.16 , Issue.5 , pp. 330-336
    • Peutzfeldt, A.1    Sahafi, A.2    Asmussen, E.3
  • 18
    • 0033232260 scopus 로고    scopus 로고
    • Contemporary issues in photocuring
    • Rueggeberg F (1999) Contemporary issues in photocuring Compendium 20(25) S4-S15.
    • (1999) Compendium , vol.20 , Issue.25
    • Rueggeberg, F.1
  • 19
    • 0024023292 scopus 로고
    • Correlation of parameters used to estimate monomer conversion in a light-cured composite
    • Rueggeberg FA & Craig RG (1988) Correlation of parameters used to estimate monomer conversion in a light-cured composite Journal of Dental Research 67(6) 932-937.
    • (1988) Journal of Dental Research , vol.67 , Issue.6 , pp. 932-937
    • Rueggeberg, F.A.1    Craig, R.G.2
  • 20
    • 0032247580 scopus 로고    scopus 로고
    • Temperature rise during polymerization of light-activated resin composites
    • Shortall AC & Harrington (1998) Temperature rise during polymerization of light-activated resin composites Journal of Oral Rehabilitation 25(12) 908-913.
    • (1998) Journal of Oral Rehabilitation , vol.25 , Issue.12 , pp. 908-913
    • Shortall, A.C.1    Harrington2
  • 22
    • 0346037070 scopus 로고    scopus 로고
    • Polymerization and light-induced heat of dental composite cured with LED and halogen technology
    • Uhl A, Mills RW & Jandt KD (2003) Polymerization and light-induced heat of dental composite cured with LED and halogen technology Biomaterials 24(10) 1809-1820.
    • (2003) Biomaterials , vol.24 , Issue.10 , pp. 1809-1820
    • Uhl, A.1    Mills, R.W.2    Jandt, K.D.3
  • 23
    • 0035459157 scopus 로고    scopus 로고
    • Influence of light energy density on effectiveness of composite cure
    • Yap AUJ & Seneviratne C (2001) Influence of light energy density on effectiveness of composite cure Operative Dentistry 26(5) 460-466.
    • (2001) Operative Dentistry , vol.26 , Issue.5 , pp. 460-466
    • Yap, A.U.J.1    Seneviratne, C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.