-
1
-
-
0026976849
-
Accurate calibration of cameras and range imaging sensors, the NPBS method
-
Nice France, May
-
G. Champleboux, S. Lavallee, P. Sautot, and P. Cinquin. Accurate calibration of cameras and range imaging sensors, the NPBS method. In IEEE Int. Conf. on Robotics and Automation, pages 1552–1558, Nice France, May 1992.
-
(1992)
IEEE Int. Conf. on Robotics and Automation
, pp. 1552-1558
-
-
Champleboux, G.1
Lavallee, S.2
Sautot, P.3
Cinquin, P.4
-
2
-
-
84957054684
-
-
H.U. Lemke, editor, CAR
-
C. Chaussat, J. Chabbal, T. Ducourant, V. Spinnler, and G. Vieux. New superior detectivity CsI/a-Si 43cm x 43cm x-ray flat panel detector for general radiography provides immediate direct digital output and easy interfacing to digital radiographic systems. In H.U. Lemke, editor, CAR, 1998.
-
(1998)
New Superior Detectivity Csi/A-Si 43Cm X 43Cm X-Ray Flat Panel Detector for General Radiography Provides Immediate Direct Digital Output and Easy Interfacing to Digital Radiographic Systems
-
-
Chaussat, C.1
Chabbal, J.2
Ducourant, T.3
Spinnler, V.4
Vieux, G.5
-
3
-
-
0031421782
-
Computer ASsisted PERicardial punctures: Work in progress
-
O. Chavanon, C. Barbe, J. Troccaz, L. Carrat, C. Ribuot, and D. Blin. Computer ASsisted PERicardial punctures: work in progress. Computer Aided Surgery, 2(6):356–364, 1997.
-
(1997)
Computer Aided Surgery
, vol.2
, Issue.6
, pp. 356-364
-
-
Chavanon, O.1
Barbe, C.2
Troccaz, J.3
Carrat, L.4
Ribuot, C.5
Blin, D.6
-
5
-
-
0028392621
-
Cone-beam reconstruction using shift variant filtering and cone beam backprojection
-
M. Defrise and R. Clack. Cone-beam reconstruction using shift variant filtering and cone beam backprojection. IEEE Trans. MI, 13:186–195, 1994.
-
(1994)
IEEE Trans. MI
, vol.13
, pp. 186-195
-
-
Defrise, M.1
Clack, R.2
-
6
-
-
0031138807
-
Echantillonnage parallèle efficace en tomographie 3D
-
L. Desbat. Echantillonnage parallèle efficace en tomographie 3D. C.R. Acad. Sci. Paris, Série I, t. 324, pages 1193–1199, 1997.
-
(1997)
C.R. Acad. Sci. Paris, Série I, T
, vol.324
, pp. 1193-1199
-
-
Desbat, L.1
-
7
-
-
0021445363
-
Practical cone-beam algorithm
-
I.A. Feldkamp, L.C. Davis, and J.W. Kress. Practical cone-beam algorithm. J. Opt. Soc. Am. A, 1(6):612–619, 1984.
-
(1984)
J. Opt. Soc. Am. A
, vol.1
, Issue.6
, pp. 612-619
-
-
Feldkamp, I.A.1
Davis, L.C.2
Kress, J.W.3
-
8
-
-
0002603379
-
Nonrigid 3-D/2-D Registration of Images Using Statistical Models
-
accepted
-
M. Fleute and S. Lavallee. Nonrigid 3-D/2-D Registration of Images Using Statistical Models. In MICCAI’99, 1999. accepted.
-
(1999)
MICCAI’99
-
-
Fleute, M.1
Lavallee, S.2
-
9
-
-
0002882706
-
A fast Monte Carlo cross-validation procedure for large least squares problems with noisy data
-
D.A. Girard. A fast Monte Carlo cross-validation procedure for large least squares problems with noisy data. Numer. Math., 56:1–23, 1989.
-
(1989)
Numer. Math
, vol.56
, pp. 1-23
-
-
Girard, D.A.1
-
10
-
-
0001555721
-
Asymptotic optimality of the fast randomized versions of GCV and CL in ridge regression and regularisation
-
D.A. Girard. Asymptotic optimality of the fast randomized versions of GCV and CL in ridge regression and regularisation. Ann. of Stat., 19(4):1950–1963, 1991.
-
(1991)
Ann. of Stat
, vol.19
, Issue.4
, pp. 1950-1963
-
-
Girard, D.A.1
-
11
-
-
84957086131
-
Reconstruction d’images tridimensionnelles
-
Thèse d’habilitation à diriger des recherches
-
P. Grangeat. Reconstruction d’images tridimensionnelles. INPG, 1993. Thèse d’habilitation à diriger des recherches.
-
(1993)
INPG
-
-
Grangeat, P.1
-
12
-
-
0000880619
-
Towards automatic registration between CT and X-ray images: Cooperation between 3D/2D registration and 2D edge detection
-
Baltimore, MA, nov, Wiley
-
A. Hamadeh, P. Sautot, S. Lavallee, and P. Cinquin. Towards automatic registration between CT and X-ray images: cooperation between 3D/2D registration and 2D edge detection. In Second Symposium on Medical Robotics and Computer Assisted Surgery Proc. (MRCAS’95), pages 39–46, Baltimore, MA, nov. 1995. Wiley.
-
(1995)
In Second Symposium on Medical Robotics and Computer Assisted Surgery Proc. (MRCAS’95)
, pp. 39-46
-
-
Hamadeh, A.1
Sautot, P.2
Lavallee, S.3
Cinquin, P.4
-
14
-
-
0032912554
-
Single-slice rebinning method for helical con-beam CT
-
F. Noo, M. Defrise, and R Clackdoyle. Single-slice rebinning method for helical con-beam CT. Phys. Med. Biol., 44:561–570, 1999.
-
(1999)
Phys. Med. Biol
, vol.44
, pp. 561-570
-
-
Noo, F.1
Defrise, M.2
Clackdoyle, R.3
-
15
-
-
0028397144
-
3D reconstruction of vascular structures from 2 X-ray angiograms using an adapted simulated annealing algorithm
-
C. Pellot, A. Herment, M. Sigelle, P. Horin, H. Maître, and P. Peronneau. 3D reconstruction of vascular structures from 2 X-ray angiograms using an adapted simulated annealing algorithm. IEEE trans. Med. Im., 13(1):48–60, 1994.
-
(1994)
IEEE Trans. Med. Im
, vol.13
, Issue.1
, pp. 48-60
-
-
Pellot, C.1
Herment, A.2
Sigelle, M.3
Horin, P.4
Maître, H.5
Peronneau, P.6
-
16
-
-
0019726966
-
Sampling the 2-D Radon transform
-
P.A. Rattey and A.G. Lindgren. Sampling the 2-D Radon transform. IEEE Trans. ASSP, 29:994-1002, 1981.
-
(1981)
IEEE Trans. ASSP
, vol.29
, pp. 994-1002
-
-
Rattey, P.A.1
Lindgren, A.G.2
|