메뉴 건너뛰기




Volumn 28, Issue 7, 2005, Pages 662-670

Trabecular metal in hip reconstructive surgery

Author keywords

[No Author keywords available]

Indexed keywords

BIOMATERIAL; CARBON; METAL; POLYURETHAN FOAM; TANTALUM;

EID: 22544475576     PISSN: 01477447     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (36)

References (25)
  • 1
    • 0014983592 scopus 로고
    • Sintered fiber metal composites as a basis for attachment of implants to bone
    • Galante J, Rostoker W, Lueck R, Ray RD. Sintered fiber metal composites as a basis for attachment of implants to bone. J Bone Joint Surg Am. 1971; 53:101-114.
    • (1971) J. Bone Joint Surg. Am. , vol.53 , pp. 101-114
    • Galante, J.1    Rostoker, W.2    Lueck, R.3    Ray, R.D.4
  • 3
    • 0018970317 scopus 로고
    • The optimum pore size for the fixation of porous-surface metal implants by the ingrowth of bone
    • Bobyn JD, Pilliar RM, Cameron HU, Weatherly GC. The optimum pore size for the fixation of porous-surface metal implants by the ingrowth of bone. Clin Orthop. 1980; 150:263-270.
    • (1980) Clin. Orthop. , vol.150 , pp. 263-270
    • Bobyn, J.D.1    Pilliar, R.M.2    Cameron, H.U.3    Weatherly, G.C.4
  • 6
    • 0028059248 scopus 로고
    • Biological performance of tantalum
    • Black J. Biological performance of tantalum. Clinical Materials. 1994; 16:167-173.
    • (1994) Clinical Materials , vol.16 , pp. 167-173
    • Black, J.1
  • 7
    • 33044487666 scopus 로고    scopus 로고
    • Three Dimensional Reconstruction and Modeling of a Porous Tantalum Biomaterial
    • Presented at: Annual Meeting of the American Society for Biomaterials; April 24-29
    • Gunson A, Kral M, Poggie R. Three Dimensional Reconstruction and Modeling of a Porous Tantalum Biomaterial. Presented at: Annual Meeting of the American Society for Biomaterials; April 24-29, 2001.
    • (2001)
    • Gunson, A.1    Kral, M.2    Poggie, R.3
  • 8
    • 33044490980 scopus 로고    scopus 로고
    • Finite Element Analysis of Peri-Acetabular Stress of Cemented, Metal-Backed, and Porous Tantalum Backed Acetabular Components
    • Presented at: 45th Annual Meeting of Orthopaedic Research Society; Anaheim, Calif; February 1-4
    • Poggie RA, Brown TD, Pedersen DR. Finite Element Analysis of Peri-Acetabular Stress of Cemented, Metal-Backed, and Porous Tantalum Backed Acetabular Components. Presented at: 45th Annual Meeting of Orthopaedic Research Society; Anaheim, Calif; February 1-4, 1999.
    • (1999)
    • Poggie, R.A.1    Brown, T.D.2    Pedersen, D.R.3
  • 9
    • 0000072384 scopus 로고    scopus 로고
    • Flexural rigidity of laboratory and surgical substitutes for human fibular bone grafts
    • Heiner AD, Poggie RA, Brown TD. Flexural rigidity of laboratory and surgical substitutes for human fibular bone grafts. J Musculoskeletal Research. 1998; 2:267-272.
    • (1998) J. Musculoskeletal Research , vol.2 , pp. 267-272
    • Heiner, A.D.1    Poggie, R.A.2    Brown, T.D.3
  • 10
    • 0033755624 scopus 로고    scopus 로고
    • Reconstruction of major column defects and pelvic discontinuity in revision total hip arthroplasty
    • Stiehl JB, Saluja R, Diener T. Reconstruction of major column defects and pelvic discontinuity in revision total hip arthroplasty. J Arthroplasty. 2000; 15:849-857.
    • (2000) J. Arthroplasty , vol.15 , pp. 849-857
    • Stiehl, J.B.1    Saluja, R.2    Diener, T.3
  • 12
    • 33044485888 scopus 로고    scopus 로고
    • High specific volume bone growth into a porous tantalum structure
    • Presented at: 23rd Annual Meeting of the Society for Biomaterials; April 30-May 4, New Orleans, La
    • Claassen B, Kerns L, Gharpuray V, Black J, Powers DL. High specific volume bone growth into a porous tantalum structure. Presented at: 23rd Annual Meeting of the Society for Biomaterials; April 30-May 4, 1997; New Orleans, La.
    • (1997)
    • Claassen, B.1    Kerns, L.2    Gharpuray, V.3    Black, J.4    Powers, D.L.5
  • 13
    • 10344223225 scopus 로고
    • Evaluation of tantalum foam, a novel porous material, for bone ingrowth fixation using a canine model
    • Turner TM, Urban RM, Berzins A, Sumner DR. Evaluation of tantalum foam, a novel porous material, for bone ingrowth fixation using a canine model. Trans Soc Biomaterials. 1995; 21:125.
    • (1995) Trans. Soc. Biomaterials , vol.21 , pp. 125
    • Turner, T.M.1    Urban, R.M.2    Berzins, A.3    Sumner, D.R.4
  • 15
    • 33044482989 scopus 로고    scopus 로고
    • The tissue response to noncemented canine acetabular cups with porous tantalum backing
    • Presented at: 44th Annual Orthopaedic Research Society; March 16-19, New Orleans, La
    • Toh K-K, Hacking SA, Bobyn JD, Tanzer M, Krygier H. The tissue response to noncemented canine acetabular cups with porous tantalum backing. Presented at: 44th Annual Orthopaedic Research Society; March 16-19, 2001; New Orleans, La.
    • (2001)
    • Toh, K.-K.1    Hacking, S.A.2    Bobyn, J.D.3    Tanzer, M.4    Krygier, H.5
  • 17
    • 33044493904 scopus 로고    scopus 로고
    • Characterization of a porous metal, direct compression molded UHMWPE junction
    • Presented at: 44th Annual Meeting of Orthopaedic Research Society; March 16-19, New Orleans, La
    • Poggie RA, Cohen RC, Averill RG. Characterization of a porous metal, direct compression molded UHMWPE junction. Presented at: 44th Annual Meeting of Orthopaedic Research Society; March 16-19, 2001; New Orleans, La.
    • (2001)
    • Poggie, R.A.1    Cohen, R.C.2    Averill, R.G.3
  • 18
    • 4243970492 scopus 로고    scopus 로고
    • Elimination of cup-liner micromotion in acetabular components
    • Presented at: 25th Annual Meeting of Society for Biomaterials; April 28-May 2, Providence, RI
    • Litsky AS. Elimination of cup-liner micromotion in acetabular components. Presented at: 25th Annual Meeting of Society for Biomaterials; April 28-May 2, 1999; Providence, RI.
    • (1999)
    • Litsky, A.S.1
  • 19
    • 33044502391 scopus 로고    scopus 로고
    • Implant design and mechanical & tribological characterization of low-wear artificial hip joints
    • Presented at: 7th Annual International Biolox Symposium 2002; March 15-16, Stuttgart, Germany
    • Poggie RA, Coutts RD. Implant design and mechanical & tribological characterization of low-wear artificial hip joints. Presented at: 7th Annual International Biolox Symposium 2002; March 15-16, 2002; Stuttgart, Germany.
    • (2002)
    • Poggie, R.A.1    Coutts, R.D.2
  • 20
    • 16244381109 scopus 로고    scopus 로고
    • Radiographic analysis of a porous tantalum monoblock acetabular cup with 2 to 5 year follow-Up
    • Gruen TA, Poggie RA, Lewallen DG, et al. Radiographic analysis of a porous tantalum monoblock acetabular cup with 2 to 5 year follow-Up. J Arthroplasty. 2005; 20:369-378.
    • (2005) J. Arthroplasty , vol.20 , pp. 369-378
    • Gruen, T.A.1    Poggie, R.A.2    Lewallen, D.G.3
  • 21
    • 33044504406 scopus 로고    scopus 로고
    • MonoBlock trabecular metal acetabulum: Two to five year results
    • Presented at: Annual Meeting of the American Academy of Orthopaedic Surgeons; February 5-7, New Orleans, La
    • Lewis RJ, O'Keefe TS, Unger A. MonoBlock trabecular metal acetabulum: two to five year results. Presented at: Annual Meeting of the American Academy of Orthopaedic Surgeons; February 5-7, 2003; New Orleans, La.
    • (2003)
    • Lewis, R.J.1    O'Keefe, T.S.2    Unger, A.3
  • 22
    • 33044482726 scopus 로고    scopus 로고
    • Cementless acetabular revision using trabecular metal
    • Presented at: Annual Meeting of the American Academy of Orthopaedic Surgeons; February 13-17, Dallas, Tex
    • Unger AS, Lewis RJ. Cementless acetabular revision using trabecular metal. Presented at: Annual Meeting of the American Academy of Orthopaedic Surgeons; February 13-17, 2002; Dallas, Tex.
    • (2002)
    • Unger, A.S.1    Lewis, R.J.2
  • 23
    • 33044502108 scopus 로고    scopus 로고
    • Use of porous tantalum in total hip arthroplasty
    • The Harvard Hip Course; 2002; October 2-5, Boston, Mass
    • Lewallen D. Use of porous tantalum in total hip arthroplasty. The Harvard Hip Course; 2002; October 2-5, 2002; Boston, Mass.
    • (2002)
    • Lewallen, D.1
  • 24
    • 0025720134 scopus 로고
    • Pigmented villonodular synovitis of the hip joint: An unusual case
    • Stiehl JB. Pigmented villonodular synovitis of the hip joint: an unusual case. J Arthroplasty. 1991; 6:85-90.
    • (1991) J. Arthroplasty , vol.6 , pp. 85-90
    • Stiehl, J.B.1
  • 25
    • 10344246333 scopus 로고    scopus 로고
    • Characterization of a new porous tantalum biomaterial for reconstructive orthopaedics
    • Presented at: Annual Meeting of the American Academy of Orthopaedic Surgeons; February 4-8, Anaheim, Calif
    • Bobyn JD, Hacking SA, Chan SP, Toh KK, Krygier JJ, Tanzer M. Characterization of a new porous tantalum biomaterial for reconstructive orthopaedics. Presented at: Annual Meeting of the American Academy of Orthopaedic Surgeons; February 4-8, 1999; Anaheim, Calif.
    • (1999)
    • Bobyn, J.D.1    Hacking, S.A.2    Chan, S.P.3    Toh, K.K.4    Krygier, J.J.5    Tanzer, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.