메뉴 건너뛰기




Volumn 39, Issue 13, 2005, Pages 1131-1145

Experimental study of FRP tube-encased concrete columns

Author keywords

Column; Concrete; Confinement; Encasement; FRP

Indexed keywords

COLUMNS (STRUCTURAL); COMPRESSIVE STRENGTH; CONCRETE CONSTRUCTION; CORROSION RESISTANCE; STRAIN GAGES; SURFACE TENSION; TUBES (COMPONENTS);

EID: 22544467491     PISSN: 00219983     EISSN: None     Source Type: Journal    
DOI: 10.1177/0021998305048743     Document Type: Article
Times cited : (40)

References (18)
  • 1
    • 0001762960 scopus 로고
    • Concrete encased in fiberglass-reinforced plastic
    • Fardis, M.N. and Khalili, H.H. (1981). Concrete Encased in Fiberglass-reinforced Plastic, ACI Journal, 78: 440-446.
    • (1981) ACI Journal , vol.78 , pp. 440-446
    • Fardis, M.N.1    Khalili, H.H.2
  • 3
    • 0029723735 scopus 로고    scopus 로고
    • A new concrete-filled hollow FRP composite column
    • Mirmiran, A. (1996). A New Concrete-filled Hollow FRP Composite Column, Composites Part B: Engineering, 27B: 263-268.
    • (1996) Composites Part B: Engineering , vol.27 B , pp. 263-268
    • Mirmiran, A.1
  • 5
    • 0031142537 scopus 로고    scopus 로고
    • Behavior of concrete columns confined by fiber composites
    • Mirmiran, A. and Shahawy, M. (1997). Behavior of Concrete Columns Confined by Fiber Composites, ASCE Journal of Structure Engineering, 123: 583-590.
    • (1997) ASCE Journal of Structure Engineering , vol.123 , pp. 583-590
    • Mirmiran, A.1    Shahawy, M.2
  • 7
    • 0035412974 scopus 로고    scopus 로고
    • Confinement model for axially loaded concrete confined by FRP tubes
    • Fam, A.Z. and Rizkalla, S.H. (2001). Confinement Model for Axially Loaded Concrete Confined by FRP Tubes, ACI Structural Journal, 98: 451-461.
    • (2001) ACI Structural Journal , vol.98 , pp. 451-461
    • Fam, A.Z.1    Rizkalla, S.H.2
  • 8
    • 0037880688 scopus 로고    scopus 로고
    • Flexural behavior of concrete-filled fiber-reinforced polymer circular tubes
    • Fam, A.Z. and Rizkalla, S.H. (2002). Flexural Behavior of Concrete-Filled Fiber-Reinforced Polymer Circular Tubes, ASCE Journal of Composites for Construction, 6: 123-132.
    • (2002) ASCE Journal of Composites for Construction , vol.6 , pp. 123-132
    • Fam, A.Z.1    Rizkalla, S.H.2
  • 9
    • 0034236937 scopus 로고    scopus 로고
    • Performance of fiber-reinforced polymer-wrapped reinforced concrete column under combined axial-flexural loading
    • Chaallal, O. and Shahawy, M. (2000). Performance of Fiber-reinforced Polymer-wrapped Reinforced Concrete Column Under Combined Axial-Flexural Loading, ACI Structural Journal, 97: 559-668.
    • (2000) ACI Structural Journal , vol.97 , pp. 559-668
    • Chaallal, O.1    Shahawy, M.2
  • 11
    • 0041559944 scopus 로고    scopus 로고
    • Experimental and analytical modeling of concrete-filled fiber-reinforced polymer tubes subjected to combined bending and axial loads
    • Fam, A.Z. Flisak, B. and Rizkalla, S. (2003). Experimental and Analytical Modeling of Concrete-filled Fiber-reinforced Polymer Tubes Subjected to Combined Bending and Axial Loads, ACI Structural Journal, 100: 499-509.
    • (2003) ACI Structural Journal , vol.100 , pp. 499-509
    • Fam, A.Z.1    Flisak, B.2    Rizkalla, S.3
  • 13
    • 0035479353 scopus 로고    scopus 로고
    • Durability studies on concrete columns encased in PVC-FRP composite tubes
    • Toutanji, H. and Saafi, M. (2001). Durability Studies on Concrete Columns Encased in PVC-FRP Composite Tubes, Composite Structures, 54: 27-35.
    • (2001) Composite Structures , vol.54 , pp. 27-35
    • Toutanji, H.1    Saafi, M.2
  • 14
    • 0034485213 scopus 로고    scopus 로고
    • Self-weight buckling of FRP tubes filled with wet concrete
    • Teng, J.G. and Yao, J. (2000). Self-weight Buckling of FRP Tubes Filled with Wet Concrete, Thin-Walled Structures, 38: 337-353
    • (2000) Thin-Walled Structures , vol.38 , pp. 337-353
    • Teng, J.G.1    Yao, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.