메뉴 건너뛰기




Volumn 18, Issue 2, 2005, Pages 293-312

Auto-PEEP: How to detect and how to prevent - A review

Author keywords

ARDS; Asthma; Auto PEEP; COPD; Dynamic hyperinflation; Intrinsic peep; Mechanical ventilation; Occult peep

Indexed keywords

ARTIFICIAL VENTILATION; HUMAN; POSITIVE END EXPIRATORY PRESSURE; REVIEW;

EID: 22544460262     PISSN: 05440440     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (13)

References (51)
  • 1
    • 0019989011 scopus 로고
    • Occult positive end-expiratory pressure in mechanically ventilated patients with airflow obstruction. The auto-PEEP effect
    • PEPE PE, MARINI JJ: Occult positive end-expiratory pressure in mechanically ventilated patients with airflow obstruction. The auto-PEEP effect. Am Rev Respir Dis; 126:166-170, 1982.
    • (1982) Am Rev Respir Dis , vol.126 , pp. 166-170
    • Pepe, P.E.1    Marini, J.J.2
  • 2
    • 0030055338 scopus 로고    scopus 로고
    • Intrinsic PEEP and cardiopulmonary interaction in patients with COPD and acute ventilatory failure
    • RANIERI VM, DAMBROSIO M, BRIENZA N: Intrinsic PEEP and cardiopulmonary interaction in patients with COPD and acute ventilatory failure. Eur Respir J; 9:1283-1292, 1996.
    • (1996) Eur Respir J , vol.9 , pp. 1283-1292
    • Ranieri, V.M.1    Dambrosio, M.2    Brienza, N.3
  • 3
    • 0029872446 scopus 로고    scopus 로고
    • Low measured auto-positive end expiratory pressure during mechanical ventilation of patient with severe asthma. Hidden auto-positive end-expiratory pressure
    • LEATHERMAN JW, RAVENSCRAFT SA: Low measured auto-positive end expiratory pressure during mechanical ventilation of patient with severe asthma. Hidden auto-positive end-expiratory pressure. Crit Care Med; 24:541-546, 1996.
    • (1996) Crit Care Med , vol.24 , pp. 541-546
    • Leatherman, J.W.1    Ravenscraft, S.A.2
  • 4
    • 0034070154 scopus 로고    scopus 로고
    • Expiratory flow limitation and intrinsic positive end-expiratory pressure at zero positive end-expiratory pressure in patients with adult respiratory distress syndrome
    • KOPUTSOUKOU A, ARMAGANIDIS A, STAVRAKAKI-KALLERGI C, VASSILAKOPOULOS T, LYMBERIS A, ROUSSOS C ET AL: Expiratory flow limitation and intrinsic positive end-expiratory pressure at zero positive end-expiratory pressure in patients with adult respiratory distress syndrome. Am J Respir Crit Care Med; 161:1590-1596, 2000.
    • (2000) Am J Respir Crit Care Med , vol.161 , pp. 1590-1596
    • Koputsoukou, A.1    Armaganidis, A.2    Stavrakaki-Kallergi, C.3    Vassilakopoulos, T.4    Lymberis, A.5    Roussos, C.6
  • 5
    • 0027278581 scopus 로고
    • Volume-controlled inverse ratio ventilation: Effect on dynamic hyperinflation and auto-PEEP
    • VALTA P, TAKALA J: Volume-controlled inverse ratio ventilation: effect on dynamic hyperinflation and auto-PEEP. Acta Anaesthesiol Scand; 37:323-328, 1993.
    • (1993) Acta Anaesthesiol Scand , vol.37 , pp. 323-328
    • Valta, P.1    Takala, J.2
  • 7
    • 0021801538 scopus 로고
    • Measurement of static compliance of the total respiratory system in patients with acute respiratory failure during mechanical ventilation: The effect of "intrinsic" PEEP
    • ROSSI A, GOTTFRIED SB, ZOCCHI L, HIGGS BD, LENNOX S, CALVERLEY PM ET AL: Measurement of static compliance of the total respiratory system in patients with acute respiratory failure during mechanical ventilation: the effect of "intrinsic" PEEP. Am Rev Respir Dis; 131:672-767, 1985.
    • (1985) Am Rev Respir Dis , vol.131 , pp. 672-767
    • Rossi, A.1    Gottfried, S.B.2    Zocchi, L.3    Higgs, B.D.4    Lennox, S.5    Calverley, P.M.6
  • 8
    • 0031665783 scopus 로고    scopus 로고
    • Mechanical ventilation of the patient with severe chronic obstructive pulmonary disease
    • GLADWIN MT, PIERSON DJ: Mechanical ventilation of the patient with severe chronic obstructive pulmonary disease. Intensive Care Med; 24:898-910, 1998.
    • (1998) Intensive Care Med , vol.24 , pp. 898-910
    • Gladwin, M.T.1    Pierson, D.J.2
  • 9
    • 7144235323 scopus 로고
    • Acute severe asthma
    • Oh TE (ed.) Butterworths, Sydney
    • rd ed. Butterworths, Sydney, pp 192-199, 1990.
    • (1990) rd Ed. , pp. 192-199
    • Tuxen, D.V.1    Oh, T.E.2
  • 10
    • 0000690942 scopus 로고
    • Auto-PEEP is common in mechanically ventilated patients: A study of incidence, severity and detection
    • BROWN DG, PIERSON DJ: Auto-PEEP is common in mechanically ventilated patients: a study of incidence, severity and detection. Respiratory Care; 31:1069-1073, 1986.
    • (1986) Respiratory Care , vol.31 , pp. 1069-1073
    • Brown, D.G.1    Pierson, D.J.2
  • 11
    • 0025314347 scopus 로고
    • Intrinsic peep and arterial PCO2 in stable patients with chronic obstructive pulmonary disease
    • HALUSZKA J, CHARTRAND DA, GRASSINO AE, MILIC-EMILI J: Intrinsic peep and arterial PCO2 in stable patients with chronic obstructive pulmonary disease. Am Rev Respir Dis; 141:1197-1197, 1990.
    • (1990) Am Rev Respir Dis , vol.141 , pp. 1197-1197
    • Haluszka, J.1    Chartrand, D.A.2    Grassino, A.E.3    Milic-Emili, J.4
  • 12
    • 0025254617 scopus 로고
    • Auto-PEEP in patients with multisystemic failure: An ambiguous compliance
    • MOORE FA, HAENEL JB, MOORE EE, ABERNATHY CM: Auto-PEEP in patients with multisystemic failure: an ambiguous compliance. J Trauma; 30:1316-1323, 1990.
    • (1990) J Trauma , vol.30 , pp. 1316-1323
    • Moore, F.A.1    Haenel, J.B.2    Moore, E.E.3    Abernathy, C.M.4
  • 13
    • 0029870574 scopus 로고    scopus 로고
    • Occult, occult auto-PEEP in status asthmaticus
    • STEWART T, SLUTSKY AS: Occult, occult auto-PEEP in status asthmaticus. Crit Care Med; 24:379-380, 1996.
    • (1996) Crit Care Med , vol.24 , pp. 379-380
    • Stewart, T.1    Slutsky, A.S.2
  • 14
    • 0021801369 scopus 로고
    • Work of breathing in patients with chronic obstructive pulmonary disease in acute respiratory failure
    • FLEURY B, MURAIANA D, TALAMO C: Work of breathing in patients with chronic obstructive pulmonary disease in acute respiratory failure. Am Rev Respir Dis; 131:822-27, 1985.
    • (1985) Am Rev Respir Dis , vol.131 , pp. 822-827
    • Fleury, B.1    Muraiana, D.2    Talamo, C.3
  • 15
    • 0023019984 scopus 로고
    • The pattern of breathing during successful and unsuccessful trials of weaning from mechanical ventilation
    • TOBIN MJ, PEREZ W, GUENTHER SM, SEMMES BJ, MADOR MJ, ALLEN SJ ET AL: The pattern of breathing during successful and unsuccessful trials of weaning from mechanical ventilation. Am Rev Respir Dis; 134:1111-1118, 1986.
    • (1986) Am Rev Respir Dis , vol.134 , pp. 1111-1118
    • Tobin, M.J.1    Perez, W.2    Guenther, S.M.3    Semmes, B.J.4    Mador, M.J.5    Allen, S.J.6
  • 16
    • 0026760605 scopus 로고
    • Pulmonary barotrauma in mechanical ventilation. Patterns and risk factors
    • GAMMON RB, SHIN MS, BUCHALTER SE: Pulmonary barotrauma in mechanical ventilation. Patterns and risk factors. Chest; 102:568-572, 1992.
    • (1992) Chest , vol.102 , pp. 568-572
    • Gammon, R.B.1    Shin, M.S.2    Buchalter, S.E.3
  • 17
    • 0023603475 scopus 로고
    • The effects of ventilatory pattern on hyperinflation airway pressures, and circulation in mechanical ventilation of patients with severe airflow obstruction
    • TUXEN DV, LANE S: The effects of ventilatory pattern on hyperinflation airway pressures, and circulation in mechanical ventilation of patients with severe airflow obstruction. Am Rev Respir Dis.; 136:872-879, 1987.
    • (1987) Am Rev Respir Dis , vol.136 , pp. 872-879
    • Tuxen, D.V.1    Lane, S.2
  • 18
    • 0026447061 scopus 로고
    • Use of a measurement of pulmonary hyperinflation to control the level of mechanical ventilation in patients with acute severe asthma
    • TUXEN DV, WILLIAM TJ, SCHEINKESTEL D, CZARMY, BOWES G: Use of a measurement of pulmonary hyperinflation to control the level of mechanical ventilation in patients with acute severe asthma. Am Rev Resp Dis; 146:1136-1142, 1992.
    • (1992) Am Rev Resp Dis , vol.146 , pp. 1136-1142
    • Tuxen, D.V.1    William, T.J.2    Scheinkestel, D.3    Czarmy4    Bowes, G.5
  • 19
    • 0026799254 scopus 로고
    • Risk factors for morbidity in mechanically ventilated patients with acute severe asthma
    • WILLIAMS TJ, TUXEN DV, SCHEINKESTEL CD, CZARNY D, BOWES G: Risk factors for morbidity in mechanically ventilated patients with acute severe asthma, Am Rev Respir Dis; 146:607-613, 1992.
    • (1992) Am Rev Respir Dis , vol.146 , pp. 607-613
    • Williams, T.J.1    Tuxen, D.V.2    Scheinkestel, C.D.3    Czarny, D.4    Bowes, G.5
  • 20
    • 0025352797 scopus 로고
    • Intensive care of status asthmaticus. A 10-year experience
    • BRAMAN SS, KAEMMERLEN JT: Intensive care of status asthmaticus. A 10-year experience. JAMA; 264:366-368, 1990.
    • (1990) JAMA , vol.264 , pp. 366-368
    • Braman, S.S.1    Kaemmerlen, J.T.2
  • 22
    • 0018601944 scopus 로고
    • Lung expansion, airway pressure transmission, and positive end-expiratory pressure
    • CHAPIN JC, DOWNS JB, DOUGLAS ME, MURPHY EJ, RUIZ BC: Lung expansion, airway pressure transmission, and positive end-expiratory pressure. Arch Surg. 114:1193-1197, 1979.
    • (1979) Arch Surg , vol.114 , pp. 1193-1197
    • Chapin, J.C.1    Downs, J.B.2    Douglas, M.E.3    Murphy, E.J.4    Ruiz, B.C.5
  • 24
    • 0028182282 scopus 로고
    • Effects of intrinsic PEEP on ventilation-perfusion mismatching mechanically ventilated patients with acute or chronic airway obstruction
    • ROSSI A, SANTOS C, ROCA J, TORRES A, FELEZ MA, RODRIGUEZ-ROISIN R: Effects of intrinsic PEEP on ventilation-perfusion mismatching mechanically ventilated patients with acute or chronic airway obstruction. Am J Respir Crit Care Med; 149:1077-1084, 1994.
    • (1994) Am J Respir Crit Care Med , vol.149 , pp. 1077-1084
    • Rossi, A.1    Santos, C.2    Roca, J.3    Torres, A.4    Felez, M.A.5    Rodriguez-Roisin, R.6
  • 25
    • 0023083427 scopus 로고
    • Phasic changes of right ventricular ejection fraction in patients with acute exacerbations of chronic obstructive pulmonary disease
    • DHAINAUT JF, BRUNET F: Phasic changes of right ventricular ejection fraction in patients with acute exacerbations of chronic obstructive pulmonary disease. Intensive Care Med; 13:214-215, 1987.
    • (1987) Intensive Care Med , vol.13 , pp. 214-215
    • Dhainaut, J.F.1    Brunet, F.2
  • 26
    • 0029796478 scopus 로고    scopus 로고
    • Auto-PEEP and electromechanical dissociation
    • LAPINSKY SE, LEUNG RS: Auto-PEEP and electromechanical dissociation. N Engl J Med; 335:674, 1996.
    • (1996) N Engl J Med , vol.335 , pp. 674
    • Lapinsky, S.E.1    Leung, R.S.2
  • 27
    • 0026586229 scopus 로고
    • Lung hyperinflation caused by inappropriate ventilation resulting in electromechanical dissociation. A case report
    • KOLLEF MH: Lung hyperinflation caused by inappropriate ventilation resulting in electromechanical dissociation. A case report. Heart Lung; 21:74-77, 1992.
    • (1992) Heart Lung , vol.21 , pp. 74-77
    • Kollef, M.H.1
  • 28
    • 0028291502 scopus 로고
    • Life-threatening hypotension associated with emergency intubation and the initiation of mechanical ventilation
    • FRANKLIN C, SAMUEL J, HU TC: Life-threatening hypotension associated with emergency intubation and the initiation of mechanical ventilation. Am J Emerg Med; 12:425-428, 1994.
    • (1994) Am J Emerg Med , vol.12 , pp. 425-428
    • Franklin, C.1    Samuel, J.2    Hu, T.C.3
  • 29
    • 0028937925 scopus 로고
    • Intraoperative cardiac arrest after unrecognized dynamic hyperinflation
    • MYLES PS, MADDER H, MORGAN EB: Intraoperative cardiac arrest after unrecognized dynamic hyperinflation. Br J Anaesth; 74:340-342, 1995.
    • (1995) Br J Anaesth , vol.74 , pp. 340-342
    • Myles, P.S.1    Madder, H.2    Morgan, E.B.3
  • 30
    • 0026092619 scopus 로고
    • Auto-PEEP during CPR. An "Occult" Cause of Electromechanical Dissociation?
    • ROGERS PL, SCHLICHTIG R, MIRO A, PINSKY M: Auto-PEEP During CPR. An "Occult" Cause of Electromechanical Dissociation? Chest; 99:492-493, 1991.
    • (1991) Chest , vol.99 , pp. 492-493
    • Rogers, P.L.1    Schlichtig, R.2    Miro, A.3    Pinsky, M.4
  • 31
    • 0023884345 scopus 로고
    • Prediction of electromechanical disassociation during cardiac arrest
    • SUTTON-TYRELL K, ABRAMSON SM, SAFAR P, DETIE K: Prediction of electromechanical disassociation during cardiac arrest. Ann Emerg Med; 17:572-575, 1988.
    • (1988) Ann Emerg Med , vol.17 , pp. 572-575
    • Sutton-Tyrell, K.1    Abramson, S.M.2    Safar, P.3    Detie, K.4
  • 32
    • 22544483676 scopus 로고    scopus 로고
    • Management of life threatening airway obstruction
    • Ed Vincent JL
    • HALL JB: Management of life threatening airway obstruction. Yearbook of Intensive Care and Emergency medicine; Ed Vincent JL. pp. 469-86, 1996.
    • (1996) Yearbook of Intensive Care and Emergency Medicine , pp. 469-486
    • Hall, J.B.1
  • 33
    • 0025190161 scopus 로고
    • Continuous Positive Airway Pressure Reduces Work of Breathing and Dyspnea during Weaning from Mechanical Ventilation in Severe Chronic Obstructive Pulmonary Disease
    • PETROF BJ, LEGARE M, GOLDBERG P, MILIC-EMILI J, GOTTFRIED SB: Continuous Positive Airway Pressure Reduces Work of Breathing and Dyspnea During Weaning From Mechanical Ventilation in Severe Chronic Obstructive Pulmonary Disease. Am Rev Resp Dis; 141:281-289, 1990.
    • (1990) Am Rev Resp Dis , vol.141 , pp. 281-289
    • Petrof, B.J.1    Legare, M.2    Goldberg, P.3    Milic-Emili, J.4    Gottfried, S.B.5
  • 34
    • 0023742950 scopus 로고
    • Impact of PEEP on lung mechanics and work of breathing in severe airflow obstruction
    • SMITH J, MARINI JJ: Impact of PEEP on lung mechanics and work of breathing in severe airflow obstruction. J Appl Physiol; 65:1488-1499, 1988.
    • (1988) J Appl Physiol , vol.65 , pp. 1488-1499
    • Smith, J.1    Marini, J.J.2
  • 35
    • 0028296316 scopus 로고
    • Physiologic effects of positive end-expiratory pressure in patients with chronic obstructive pulmonary disease during acute exacerbations and non-invasive ventilatory assistance
    • APPENDINI L, PATESSIO A, ZANABONI S, CARONE M, GUKOV B, DONNER CF, ROSSI A: Physiologic effects of positive end-expiratory pressure in patients with chronic obstructive pulmonary disease during acute exacerbations and non-invasive ventilatory assistance. Am J Respir Crit Care Med; 149:1069-1076, 1994.
    • (1994) Am J Respir Crit Care Med , vol.149 , pp. 1069-1076
    • Appendini, L.1    Patessio, A.2    Zanaboni, S.3    Carone, M.4    Gukov, B.5    Donner, C.F.6    Rossi, A.7
  • 36
    • 0023730503 scopus 로고
    • Respiratory compliance and resistance in mechanically ventilated patients with acute respiratory failure
    • BERNASCONI M, PLOYSONGSANG Y, GOTTFRIED SB, MILIC-EMILI J, ROSSI A: Respiratory compliance and resistance in mechanically ventilated patients with acute respiratory failure. Intensive Care Med; 14:547-553, 1988.
    • (1988) Intensive Care Med , vol.14 , pp. 547-553
    • Bernasconi, M.1    Ploysongsang, Y.2    Gottfried, S.B.3    Milic-Emili, J.4    Rossi, A.5
  • 37
    • 0032925575 scopus 로고    scopus 로고
    • Clinical examination reliably detects intrinsic positive end-expiratory pressure in critically ill, mechanically ventilated patients
    • KRESS JP, O'CONNOR MF, SCHMIDT GA: Clinical examination reliably detects intrinsic positive end-expiratory pressure in critically ill, mechanically ventilated patients. Am J Respir Crit Care Med; 159:290-294, 1999.
    • (1999) Am J Respir Crit Care Med , vol.159 , pp. 290-294
    • Kress, J.P.1    O'Connor, M.F.2    Schmidt, G.A.3
  • 38
    • 85119813287 scopus 로고    scopus 로고
    • Issues in ventilator weaning
    • MACINTYRE NR: Issues in ventilator weaning. Chest; 115:1215-1216, 1999.
    • (1999) Chest , vol.115 , pp. 1215-1216
    • MacIntyre, N.R.1
  • 39
    • 0023791348 scopus 로고
    • Respiratory resistance and intrinsic positive end-expiratory pressure (PEEP) in patients with the adult respiratory distress syndrome (ARDS)
    • Broseghini C, Brandolese R, Poggi R, Bernasconi M, Manzin E, Rossi A: Respiratory resistance and intrinsic positive end-expiratory pressure (PEEP) in patients with the adult respiratory distress syndrome (ARDS). Eur Respir J; 1:726-731, 1988.
    • (1988) Eur Respir J , vol.1 , pp. 726-731
    • Broseghini, C.1    Brandolese, R.2    Poggi, R.3    Bernasconi, M.4    Manzin, E.5    Rossi, A.6
  • 41
    • 0024333713 scopus 로고
    • Should PEEP Be Used in Airflow Obstruction?
    • MARINI JJ: Should PEEP Be Used in Airflow Obstruction? Am Rev Respir Dis; 140:1-3, 1989.
    • (1989) Am Rev Respir Dis , vol.140 , pp. 1-3
    • Marini, J.J.1
  • 42
    • 0024464641 scopus 로고
    • PEEP, auto-PEEP and waterfalls
    • TOBIN MJ, LODATO FR: PEEP, auto-PEEP and waterfalls. Chest; 96:449-451, 1989.
    • (1989) Chest , vol.96 , pp. 449-451
    • Tobin, M.J.1    Lodato, F.R.2
  • 43
    • 0027454843 scopus 로고
    • Physiologic effects of positive end-expiratory pressure in patients with chronic obstructive pulmonary disease during acute ventilatory failure and controlled mechanical ventilation
    • RANIERI VM, GIULIANI R, CINNELLA G, PESCE C, BRIENZA N, IPPOLITO EL, ET AL: Physiologic effects of positive end-expiratory pressure in patients with chronic obstructive pulmonary disease during acute ventilatory failure and controlled mechanical ventilation. Am Rev Respir Dis; 147:5-13, 1993.
    • (1993) Am Rev Respir Dis , vol.147 , pp. 5-13
    • Ranieri, V.M.1    Giuliani, R.2    Cinnella, G.3    Pesce, C.4    Brienza, N.5    Ippolito, E.L.6
  • 44
    • 0024505601 scopus 로고
    • The effects of positive expiratory pressure on iso volume flow and dynamic hyperinflation in patients receiving mechanical ventilation
    • GAY PC, RODARTE JR, HUBMAYR RD: The effects of positive expiratory pressure on iso volume flow and dynamic hyperinflation in patients receiving mechanical ventilation. Am Rev Respir Dis; 139:621-6, 1989.
    • (1989) Am Rev Respir Dis , vol.139 , pp. 621-626
    • Gay, P.C.1    Rodarte, J.R.2    Hubmayr, R.D.3
  • 45
    • 0027267456 scopus 로고
    • Effects of extrinsic positive end-expiratory pressure on mechanically ventilated patients with chronic obstructive pulmonary disease and dynamic hyperinflation
    • GEORGOPOULOS D, GIANNOULI E, PATAKAS D: Effects of extrinsic positive end-expiratory pressure on mechanically ventilated patients with chronic obstructive pulmonary disease and dynamic hyperinflation. Intensive Care Med; 19:197-203, 1993.
    • (1993) Intensive Care Med , vol.19 , pp. 197-203
    • Georgopoulos, D.1    Giannouli, E.2    Patakas, D.3
  • 46
    • 0024327547 scopus 로고
    • Detrimental effects of positive end-expiratory pressure during controlled mechanical ventilation of patients with severe airflow obstruction
    • TUXEN DV: Detrimental effects of positive end-expiratory pressure during controlled mechanical ventilation of patients with severe airflow obstruction, Am Rev Respir Dis; 140:5-9, 1989.
    • (1989) Am Rev Respir Dis , vol.140 , pp. 5-9
    • Tuxen, D.V.1
  • 47
    • 0028092781 scopus 로고
    • Permissive hypercapnea ventilation
    • TUXEN DV: Permissive hypercapnea ventilation. Am J Respir Crit Care Med. 150:870-875, 1994.
    • (1994) Am J Respir Crit Care Med. , vol.150 , pp. 870-875
    • Tuxen, D.V.1
  • 48
    • 0029023284 scopus 로고
    • The assessment and management of adults with status asthmaticus
    • CORBRIDGE TC, HALL JB: The assessment and management of adults with status asthmaticus. Am J Respir Crit Care Med; 151:1296-1316, 1993.
    • (1993) Am J Respir Crit Care Med , vol.151 , pp. 1296-1316
    • Corbridge, T.C.1    Hall, J.B.2
  • 49
    • 22544476363 scopus 로고    scopus 로고
    • Ventilator management strategies for acute asthma
    • Hill NS, Levy MM, Eds. New York: Marcel Dekker
    • CORBRIDGE T, HALL JB: Ventilator management strategies for acute asthma. In: Hill NS, Levy MM, Eds. Ventilator Management Strategies for Critical Care. New York: Marcel Dekker. 327-351, 2001.
    • (2001) Ventilator Management Strategies for Critical Care , pp. 327-351
    • Corbridge, T.1    Hall, J.B.2
  • 50
    • 0031598398 scopus 로고    scopus 로고
    • Managing mechanical ventilation in status asthmaticus
    • FREICHELS T: Managing mechanical ventilation in status asthmaticus. Dimensions of Critical Care Nursing; 17:2-10, 1998.
    • (1998) Dimensions of Critical Care Nursing , vol.17 , pp. 2-10
    • Freichels, T.1
  • 51
    • 0000690941 scopus 로고
    • Relationship of endotracheal tube size to auto-PEEP at high minute ventilation
    • SCOTT LR, BENSON MS, BISHOP MJ: Relationship of endotracheal tube size to auto-PEEP at high minute ventilation. Respiratory Care. 31:1080-1082, 1986.
    • (1986) Respiratory Care , vol.31 , pp. 1080-1082
    • Scott, L.R.1    Benson, M.S.2    Bishop, M.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.