Volumn 32, Issue 7, 2005, Pages 2305-2311

Measurement of the detective quantum efficiency in digital detectors consistent with the IEC 62220-1 standard: Practical considerations regarding the choice of filter material

Author keywords

[No Author keywords available]

Indexed keywords

AMORPHOUS SILICON; EFFICIENCY; GRAIN SIZE AND SHAPE; IMAGE ACQUISITION; QUALITY CONTROL;

EID: 22544452380     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.1929187     Document Type: Article
Times cited : (25)

References (12)
  • 1
    • 0000658326 scopus 로고    scopus 로고
    • Image quality metrics for digital systems
    • edited by J. Beutel, H. L. Kundel, and R. L. van Metter (SPIE, Bellingham, WA), Chap. 3
    • J. T. Dobbins III, "Image quality metrics for digital systems," in Handbook of Medical Imaging, edited by J. Beutel, H. L. Kundel, and R. L. van Metter (SPIE, Bellingham, WA, 2000), Vol. 1, Chap. 3.
    • (2000) Handbook of Medical Imaging , vol.1
    • Dobbins III, J.T.1
  • 2
    • 66749153645 scopus 로고    scopus 로고
    • Medical electrical equipment-Characteristics of digital x-ray imaging devices-Part 1: Determination of the detective quantum efficiency
    • Geneva, Switzerland, IEC 62220-1
    • IEC, "Medical electrical equipment-Characteristics of digital x-ray imaging devices-Part 1: Determination of the detective quantum efficiency," International Electrotechnical Commission, Geneva, Switzerland, IEC 62220-1 (2003).
    • (2003) International Electrotechnical Commission
  • 3
    • 0003696431 scopus 로고
    • Medical diagnostic x-ray equipment-Radiation conditions for use in the determination of characteristics
    • Geneva, Switzerland, IEC 61267
    • IEC, "Medical diagnostic x-ray equipment-Radiation conditions for use in the determination of characteristics," International Electrotechnical Commission, Geneva, Switzerland, IEC 61267 (1994).
    • (1994) International Electrotechnical Commission
  • 5
    • 0037393386 scopus 로고    scopus 로고
    • An experimental comparison of detector performance for direct and indirect digital radiography systems
    • E. Samei and M. J. Flynn, "An experimental comparison of detector performance for direct and indirect digital radiography systems," Med. Phys. 30, 608-622 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 608-622
    • Samei, E.1    Flynn, M.J.2
  • 7
    • 0032812524 scopus 로고    scopus 로고
    • Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systems
    • E. Samei and M. J. Flynn, "Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systems," Med. Phys. 26, 1612-1623 (1999).
    • (1999) Med. Phys. , vol.26 , pp. 1612-1623
    • Samei, E.1    Flynn, M.J.2
  • 8
    • 85027230479 scopus 로고    scopus 로고
    • R. Taylor, Goodfellow Corporation, Devon PA (private communication)
    • R. Taylor, Goodfellow Corporation, Devon PA (private communication).
  • 9
    • 85027226914 scopus 로고    scopus 로고
    • A. Frederick, Alfa Aesar, Ward Hill MA (private communication)
    • A. Frederick, Alfa Aesar, Ward Hill MA (private communication).
  • 10
    • 0033800369 scopus 로고    scopus 로고
    • Dose efficiency and low-contrast detectability of an amorphous silicon x-ray detector for digital radiography
    • R. Aufrichtig and P. Xue, "Dose efficiency and low-contrast detectability of an amorphous silicon x-ray detector for digital radiography," Phys. Med. Biol. 45, 2653-2669 (2000).
    • (2000) Phys. Med. Biol. , vol.45 , pp. 2653-2669
    • Aufrichtig, R.1    Xue, P.2
  • 11
    • 0033849841 scopus 로고    scopus 로고
    • Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography)
    • J. H. Siewerdsen and D. A. Jaffray, "Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography)," Med. Phys. 27, 1903-1914 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 1903-1914
    • Siewerdsen, J.H.1    Jaffray, D.A.2
  • 12
    • 0041387333 scopus 로고    scopus 로고
    • Signal detectability in digital radiography: Spatial domain figures of merit
    • R. M. Gagne, J. S. Boswell, and K. J. Myers, "Signal detectability in digital radiography: Spatial domain figures of merit," Med. Phys. 30, 2180-2192 (2003).
    • (2003) Med. Phys. , vol.30 , pp. 2180-2192
    • Gagne, R.M.1    Boswell, J.S.2    Myers, K.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.