메뉴 건너뛰기




Volumn 66, Issue 1-4, 1996, Pages 255-258

Application of lithium fluoride dosemeters (TLD-600) in the photoneutron field mapping of a medical linear accelerator

Author keywords

[No Author keywords available]

Indexed keywords


EID: 2242452469     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/oxfordjournals.rpd.a031729     Document Type: Article
Times cited : (1)

References (16)
  • 1
    • 0015626685 scopus 로고
    • Measurement of Fast Neutrons Produced by High-energy X-ray Beams of Medical Electron Accelerators
    • Wilenzick, R. M., Almond, P. R., Oliver, G. D. and De Almeida, C. E. Measurement of Fast Neutrons Produced by High-energy X-ray Beams of Medical Electron Accelerators. Phys. Med. Biol. 18(3), 396-408 (1973).
    • (1973) Phys. Med. Biol. , vol.18 , Issue.3 , pp. 396-408
    • Wilenzick, R.M.1    Almond, P.R.2    Oliver, G.D.3    De Almeida, C.E.4
  • 2
    • 0018119422 scopus 로고
    • Fast and Slow Neutrons in an 18-MV Photon Beam from a Philips SL/75-20 Linear Accelerator
    • Gur, D., Rosen, J. C., Bukovitz, A. G. and Gill, A. W. Fast and Slow Neutrons in an 18-MV Photon Beam from a Philips SL/75-20 Linear Accelerator. Med. Phys. 5(3), 221-222 (1978).
    • (1978) Med. Phys. , vol.5 , Issue.3 , pp. 221-222
    • Gur, D.1    Rosen, J.C.2    Bukovitz, A.G.3    Gill, A.W.4
  • 3
    • 0021266808 scopus 로고
    • Neutrons from High-energy Medical Accelerators: An Estimate of Risk to the Radiotherapy Patient
    • Nath, R., Laughlin, J. S., Swanson, W. P. and Bond, V. P. Neutrons from High-energy Medical Accelerators: An Estimate of Risk to the Radiotherapy Patient. Med. Phys. 11(3), 231-241 (1984).
    • (1984) Med. Phys. , vol.11 , Issue.3 , pp. 231-241
    • Nath, R.1    Laughlin, J.S.2    Swanson, W.P.3    Bond, V.P.4
  • 5
    • 0028832963 scopus 로고
    • Photoneutrons from High Medical Linear Accelerator: Measurement of the Spectrum and Dose using a Miniature Proportional Counter
    • Kliauga, P. and Amols, H. Photoneutrons from High Medical Linear Accelerator: Measurement of the Spectrum and Dose using a Miniature Proportional Counter. Int. J. Oncol. Biol. Phys. 21(3), 629-633 (1995).
    • (1995) Int. J. Oncol. Biol. Phys. , vol.21 , Issue.3 , pp. 629-633
    • Kliauga, P.1    Amols, H.2
  • 6
    • 0018138807 scopus 로고
    • Fast and Thermal Neutron Profiles for a 25 MeV X-ray Beam
    • Price, K. W., Nath, R. and Holeman, G. R. Fast and Thermal Neutron Profiles for a 25 MeV X-ray Beam. Med. Phys. 5(4), 285-289 (1978).
    • (1978) Med. Phys. , vol.5 , Issue.4 , pp. 285-289
    • Price, K.W.1    Nath, R.2    Holeman, G.R.3
  • 7
    • 0019476434 scopus 로고
    • Use of a Neutron Remmeter to Measure Leakage Neutrons from Medical Electron Accelerators
    • Rogers, D. W. O. and Van Dyk, G. Use of a Neutron Remmeter to Measure Leakage Neutrons from Medical Electron Accelerators. Med. Phys. 8(2), 163-166 (1981).
    • (1981) Med. Phys. , vol.8 , Issue.2 , pp. 163-166
    • Rogers, D.W.O.1    Van Dyk, G.2
  • 8
    • 0020658404 scopus 로고
    • Accelerator Room Photoneutron and Photon Background Measurements using Thermoluminescent Dosemeters
    • Anderson, D. W. and Hwang, C. C. Accelerator Room Photoneutron and Photon Background Measurements using Thermoluminescent Dosemeters. Health. Phys. 44(2), 115-125 (1983).
    • (1983) Health. Phys. , vol.44 , Issue.2 , pp. 115-125
    • Anderson, D.W.1    Hwang, C.C.2
  • 10
    • 0014290143 scopus 로고
    • 3 Probe for the Lil Crystal in Neutron Rem-Meters
    • 3 Probe for the Lil Crystal in Neutron Rem-Meters. Health. Phys. 14(5), 518-520 (1968).
    • (1968) Health. Phys. , vol.14 , Issue.5 , pp. 518-520
    • Henkins, D.E.1
  • 12
    • 0040732094 scopus 로고
    • Glow Curves of Lithium Fluoride Dosimeters (TLD-600) Irradiated with Alpha Particles from an Am-241 Source
    • Mukherjee, B. and Clerke, W Glow Curves of Lithium Fluoride Dosimeters (TLD-600) Irradiated with Alpha Particles from an Am-241 Source. Nucl. Instrum. Methods A 361, 395-397 (1995).
    • (1995) Nucl. Instrum. Methods A , vol.361 , pp. 395-397
    • Mukherjee, B.1    Clerke, W.2
  • 13
    • 0027324070 scopus 로고
    • An intercomparison of Glow Curve Analysis Computer Programs: L Synthetic Glow Curves
    • Bos, A. J. J , Pitters, T. M., Gomez Ros, J. M. and Delgado, A. An intercomparison of Glow Curve Analysis Computer Programs: L Synthetic Glow Curves. Radiat. Prot. Dosim. 47(4), 473-477 (1993).
    • (1993) Radiat. Prot. Dosim. , vol.47 , Issue.4 , pp. 473-477
    • Bos, A.J.J.1    Pitters, T.M.2    Gomez Ros, J.M.3    Delgado, A.4
  • 14
    • 2242492453 scopus 로고
    • LiF(TLD-600) Thermoluminescence Detectors for Mixed Thermal Neutron and Gamma Dosimetry
    • Krakow, Poland, August
    • Nash, A. E. and Johnson, T. L. LiF(TLD-600) Thermoluminescence Detectors for Mixed Thermal Neutron and Gamma Dosimetry. In. Proc. 4th Int. Conf. on Luminescence Dosimetry, Krakow, Poland, August 1974.
    • (1974) Proc. 4th Int. Conf. on Luminescence Dosimetry
    • Nash, A.E.1    Johnson, T.L.2
  • 16
    • 0026486594 scopus 로고
    • Evaluation of the Undesired Neutron Dose Equivalent to Critical Organs in Patients Treated by Linear Accelerator Gamma Ray Therapy
    • Manfredotti, C., Natasi, U., Oranto, E. and Zanini, A. Evaluation of the Undesired Neutron Dose Equivalent to Critical Organs in Patients Treated by Linear Accelerator Gamma Ray Therapy. Radiat. Prot. Dosim. 44(1-4), 457-462 (1992).
    • (1992) Radiat. Prot. Dosim. , vol.44 , Issue.1-4 , pp. 457-462
    • Manfredotti, C.1    Natasi, U.2    Oranto, E.3    Zanini, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.