메뉴 건너뛰기




Volumn 20, Issue 3, 2005, Pages 325-332

OEDIPE: A personalized dosimetric tool associating voxel-based models with MCNPX

Author keywords

Monte Carlo; Specific dosimetry; Targeted radiotherapy; Voxel based models

Indexed keywords

TECHNETIUM 99M;

EID: 22344456209     PISSN: 10849785     EISSN: None     Source Type: Journal    
DOI: 10.1089/cbr.2005.20.325     Document Type: Conference Paper
Times cited : (42)

References (17)
  • 2
    • 0033863161 scopus 로고    scopus 로고
    • Dosimetry and microdosimetry of targeted radiotherapy
    • Bardiès M, Pihet P. Dosimetry and microdosimetry of targeted radiotherapy. Curr Pharmaceut Des 2000; 6:1469.
    • (2000) Curr Pharmaceut des , vol.6 , pp. 1469
    • Bardiès, M.1    Pihet, P.2
  • 3
    • 22344438460 scopus 로고    scopus 로고
    • New tools based on voxel phantom for both internal and external exposures dose assessment
    • in press
    • Aubineau-Lanièce I, De Carlan L, Clairand I, et al. New tools based on voxel phantom for both internal and external exposures dose assessment. Radiat Prot Dosim 2004; in press.
    • (2004) Radiat Prot Dosim
    • Aubineau-Lanièce, I.1    De Carlan, L.2    Clairand, I.3
  • 5
    • 0033861906 scopus 로고    scopus 로고
    • Absorbed fractions in a voxel-based phantom calculated with the MCNP-4B code
    • Yoriyaz H, Dos Santos A. Absorbed fractions in a voxel-based phantom calculated with the MCNP-4B code. Med Phys 2000;27(7);1555.
    • (2000) Med Phys , vol.27 , Issue.7 , pp. 1555
    • Yoriyaz, H.1    Dos Santos, A.2
  • 6
    • 0027958158 scopus 로고
    • Computerized 3-dimensional segmented human anatomy
    • Zubal IG, Harrell CR, Smith EO, et al. Computerized 3-dimensional segmented human anatomy. Med Phys 1994;21:299.
    • (1994) Med Phys , vol.21 , pp. 299
    • Zubal, I.G.1    Harrell, C.R.2    Smith, E.O.3
  • 7
    • 0003682469 scopus 로고
    • Tissue substitutes in radiation dosimetry and measurement
    • Maryland: Bethesda
    • International Commission on Radiation Units and Measurements. Tissue substitutes in radiation dosimetry and measurement. ICRU report no. 44. Maryland: Bethesda, 1989.
    • (1989) ICRU Report No. 44
  • 8
    • 0027981622 scopus 로고
    • Availability of nuclear decay data in electronic form, including beta spectra not previously published
    • Eckerman KF, Weestfall RJ, Rymann JC et al. Availability of nuclear decay data in electronic form, including beta spectra not previously published. Health Phys 1994;67:338.
    • (1994) Health Phys , vol.67 , pp. 338
    • Eckerman, K.F.1    Weestfall, R.J.2    Rymann, J.C.3
  • 11
    • 31344443159 scopus 로고    scopus 로고
    • Dosimetric comparison of Monte Carlo codes (EGS4, MCNP, MCNPX) considering external and internal exposures of the Zubal phantom to electron and photon sources
    • in press
    • Chiavassa S, Lemosquet A, Aubineau-Lanièce I, et al. Dosimetric comparison of Monte Carlo codes (EGS4, MCNP, MCNPX) considering external and internal exposures of the Zubal phantom to electron and photon sources. Radiat Prot Dosim 2004; in press.
    • (2004) Radiat Prot Dosim
    • Chiavassa, S.1    Lemosquet, A.2    Aubineau-Lanièce, I.3
  • 12
    • 0015793674 scopus 로고
    • A chemical analysis of average chain length and relationship to bone deposition in rats
    • Gaylord King A, Christy B, Hupf HB, et al. A chemical analysis of average chain length and relationship to bone deposition in rats. J Nucl Med 1973;14(9):695.
    • (1973) J Nucl Med , vol.14 , Issue.9 , pp. 695
    • Gaylord King, A.1    Christy, B.2    Hupf, H.B.3
  • 17
    • 2542493248 scopus 로고    scopus 로고
    • New thermoluminescent dosimeters (TLD): Optimization and characterization of TLD threads sterilizable by autoclave
    • Jarnet D, Denizot B, Hindré F, et al. New thermoluminescent dosimeters (TLD): Optimization and characterization of TLD threads sterilizable by autoclave. Phys Med Biol 2004;49:1803.
    • (2004) Phys Med Biol , vol.49 , pp. 1803
    • Jarnet, D.1    Denizot, B.2    Hindré, F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.