-
1
-
-
0032638277
-
Optical tomography in medical imaging
-
S. R. Arridge, "Optical tomography in medical imaging," Inverse Probl. 15, R41-R93 (1999).
-
(1999)
Inverse Probl.
, vol.15
-
-
Arridge, S.R.1
-
2
-
-
0030912458
-
Optical imaging in medicine: I. Experimental techniques
-
J. C. Hebden, S. R. Arridge, and D. T. Delpy, "Optical imaging in medicine: I. Experimental techniques," Phys. Med. Biol. 42, 825-840 (1997).
-
(1997)
Phys. Med. Biol.
, vol.42
, pp. 825-840
-
-
Hebden, J.C.1
Arridge, S.R.2
Delpy, D.T.3
-
3
-
-
85032751522
-
Imaging the body with diffuse optical tomography
-
D. A. Boas, D. H. Brooks, E. L. Miller, C. A. DiMarzio, M. Kilmer, R. J. Gaudette, and Q. Zhang, "Imaging the body with diffuse optical tomography," IEEE Signal Processing Mag. 18, 57-75 (2001).
-
(2001)
IEEE Signal Processing Mag.
, vol.18
, pp. 57-75
-
-
Boas, D.A.1
Brooks, D.H.2
Miller, E.L.3
Dimarzio, C.A.4
Kilmer, M.5
Gaudette, R.J.6
Zhang, Q.7
-
4
-
-
0037534163
-
Time-domain optical mammography: Initial clinical results on detection and characterization of breast tumors
-
D. Grosenick, K. T. Moesta, H. Wabnitz, J. Mucke, C. Stroszczynski, R. Macdonald, P. M. Schlag and H. Rinneberg, "Time-domain optical mammography: initial clinical results on detection and characterization of breast tumors," Appl. Opt. 42, 3170-3186 (2003).
-
(2003)
Appl. Opt.
, vol.42
, pp. 3170-3186
-
-
Grosenick, D.1
Moesta, K.T.2
Wabnitz, H.3
Mucke, J.4
Stroszczynski, C.5
Macdonald, R.6
Schlag, P.M.7
Rinneberg, H.8
-
5
-
-
0034164355
-
Three-dimensional diffuse optical mammography with ultrasound localization in a human subject
-
M. J. Holboke, B. J. Tromberg, X. Li, N. Shah, J. B. Fishkin, D. Kidney, J. Butler, B. Chance, and A. G. Yodh, "Three-dimensional diffuse optical mammography with ultrasound localization in a human subject," J. Biomed. Opt. 5, 237-247 (2000).
-
(2000)
J. Biomed. Opt.
, vol.5
, pp. 237-247
-
-
Holboke, M.J.1
Tromberg, B.J.2
Li, X.3
Shah, N.4
Fishkin, J.B.5
Kidney, D.6
Butler, J.7
Chance, B.8
Yodh, A.G.9
-
6
-
-
0037208240
-
Multiwavelength three-dimensional near-infrared tomography of the breast: Initial simulation, phantom and clinical results
-
H. Dehghani, B. W. Pogue, S. P. Poplack, and K. D. Paulsen, "Multiwavelength three-dimensional near-infrared tomography of the breast: initial simulation, phantom and clinical results," Appl. Opt. 42, 135-145 (2003).
-
(2003)
Appl. Opt.
, vol.42
, pp. 135-145
-
-
Dehghani, H.1
Pogue, B.W.2
Poplack, S.P.3
Paulsen, K.D.4
-
7
-
-
0347155286
-
Optical tomography of the breast using a 32-channel time-resolved imager
-
Optical Society of America, Washington, D.C.
-
J. C. Hebden, T. Bland, E. M. C. Hillman, A. P. Gibson, N. Everdell, D. T. Delpy, S. R. Arridge, and M. Douek, "Optical tomography of the breast using a 32-channel time-resolved imager," in Digest of OSA Biomedical Topical Meetings (Optical Society of America, Washington, D.C., 2002), 187-189.
-
(2002)
Digest of OSA Biomedical Topical Meetings
, pp. 187-189
-
-
Hebden, J.C.1
Bland, T.2
Hillman, E.M.C.3
Gibson, A.P.4
Everdell, N.5
Delpy, D.T.6
Arridge, S.R.7
Douek, M.8
-
8
-
-
0043265643
-
Tomographic optical breast imaging guided by three-dimensional mammography
-
A. Li, E. L. Miller, M. Kilmer, T. J. Brukilacchio, T. Chaves, J. J. Stott, Q. Zhang, T. Wu, M. Chorlton, R. H. Moore, D. B. Kopans, and D. A. Boas, "Tomographic optical breast imaging guided by three-dimensional mammography," Appl. Opt. 42, 5181-5190 (2003).
-
(2003)
Appl. Opt.
, vol.42
, pp. 5181-5190
-
-
Li, A.1
Miller, E.L.2
Kilmer, M.3
Brukilacchio, T.J.4
Chaves, T.5
Stott, J.J.6
Zhang, Q.7
Wu, T.8
Chorlton, M.9
Moore, R.H.10
Kopans, D.B.11
Boas, D.A.12
-
9
-
-
17544378924
-
Noninvasive functional imaging of human brain using light
-
D. A. Benaron, S. R. Hintz, A. Villringer, D. A. Boas, A. Kleinschmidt, J. Frahm, C. Hirth, H. Obrig, J. C. van Houten, E. L. Kermit, W.-F. Cheong, and D. K. Stevenson, "Noninvasive functional imaging of human brain using light," J. Cereb. Blood Flow Metab. 20, 469-477 (2000).
-
(2000)
J. Cereb. Blood Flow Metab.
, vol.20
, pp. 469-477
-
-
Benaron, D.A.1
Hintz, S.R.2
Villringer, A.3
Boas, D.A.4
Kleinschmidt, A.5
Frahm, J.6
Hirth, C.7
Obrig, H.8
Van Houten, J.C.9
Kermit, E.L.10
Cheong, W.-F.11
Stevenson, D.K.12
-
10
-
-
12244250141
-
Three-dimensional optical tomography of the premature infant brain
-
J. C. Hebden, A. P. Gibson, R. M. Yusof, N. Everdell, E. M. Hillman, D. T. Delpy, T. Austin, J. Meek, and J. S. Wyatt, "Three-dimensional optical tomography of the premature infant brain," Phys. Med. Biol. 47, 4155-4166 (2002).
-
(2002)
Phys. Med. Biol.
, vol.47
, pp. 4155-4166
-
-
Hebden, J.C.1
Gibson, A.P.2
Yusof, R.M.3
Everdell, N.4
Hillman, E.M.5
Delpy, D.T.6
Austin, T.7
Meek, J.8
Wyatt, J.S.9
-
11
-
-
1942424848
-
Imaging changes in blood volume and oxygenation in the newborn infant brain using three-dimensional optical tomography
-
J. C. Hebden, A. P. Gibson, T. Austin, R. M. Yusof, N. Everdell, D. T. Delpy, S. R. Arridge, J. H. Meek, and J. S. Wyatt, "Imaging changes in blood volume and oxygenation in the newborn infant brain using three-dimensional optical tomography," Phys. Med. Biol. 49, 1117-1130 (2004).
-
(2004)
Phys. Med. Biol.
, vol.49
, pp. 1117-1130
-
-
Hebden, J.C.1
Gibson, A.P.2
Austin, T.3
Yusof, R.M.4
Everdell, N.5
Delpy, D.T.6
Arridge, S.R.7
Meek, J.H.8
Wyatt, J.S.9
-
12
-
-
0001057338
-
Three-dimensional optical tomography of hemodynamics in the human head
-
A. Y. Bluestone, G. Abdouleav, C. H. Schmitz, R. L. Barbour, and A. H. Hielscher, "Three-dimensional optical tomography of hemodynamics in the human head," Opt. Express 9, 272-286 (2001).
-
(2001)
Opt. Express
, vol.9
, pp. 272-286
-
-
Bluestone, A.Y.1
Abdouleav, G.2
Schmitz, C.H.3
Barbour, R.L.4
Hielscher, A.H.5
-
13
-
-
0003136077
-
On-line optical imaging of the human brain with 160 ms temporal resolution
-
M. A. Franceschini, V. Toronov, M. E. Filiaci, E. Gratton, and S. Fantini, "On-line optical imaging of the human brain with 160 ms temporal resolution," Opt. Express 6, 49-57 (2000).
-
(2000)
Opt. Express
, vol.6
, pp. 49-57
-
-
Franceschini, M.A.1
Toronov, V.2
Filiaci, M.E.3
Gratton, E.4
Fantini, S.5
-
14
-
-
0042335783
-
A novel method for fast imaging of brain function, noninvasively, with light
-
B. Chance, E. Anday, S. Nioka, S. Zhou, L. Hong, K. Worden, C. Li, T. Murray, Y. Ovetsky, D. Pidikiti, and R. Thomas, "A novel method for fast imaging of brain function, noninvasively, with light," Opt. Express 2, 411-423 (1998).
-
(1998)
Opt. Express
, vol.2
, pp. 411-423
-
-
Chance, B.1
Anday, E.2
Nioka, S.3
Zhou, S.4
Hong, L.5
Worden, K.6
Li, C.7
Murray, T.8
Ovetsky, Y.9
Pidikiti, D.10
Thomas, R.11
-
15
-
-
0037924485
-
Advances in optical imaging of the newborn infant brain
-
J. C. Hebden, "Advances in optical imaging of the newborn infant brain," Psychophysiology 40, 501-510 (2003).
-
(2003)
Psychophysiology
, vol.40
, pp. 501-510
-
-
Hebden, J.C.1
-
16
-
-
9544247156
-
Validity Conditions for the radiative transfer equation
-
L. Marti-Lopez, J. Bouza-Dominguez, J. C. Hebden, S. R. Arridge and R. A. Martinez-Celirio, "Validity Conditions for the radiative transfer equation," J. Opt. Soc. Am. A. 20, 2046-2056 (2003).
-
(2003)
J. Opt. Soc. Am. A
, vol.20
, pp. 2046-2056
-
-
Marti-Lopez, L.1
Bouza-Dominguez, J.2
Hebden, J.C.3
Arridge, S.R.4
Martinez-Celirio, R.A.5
-
17
-
-
0017571334
-
Noninvasive infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters
-
F. F. Jobsis, "Noninvasive infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters," Science 198, 1264-1267 (1977).
-
(1977)
Science
, vol.198
, pp. 1264-1267
-
-
Jobsis, F.F.1
-
18
-
-
0023783954
-
Cotside measurement of cerebral blood flow in ill newborn infants by near infrared spectroscopy
-
A. D. Edwards, C. Richardson, M. Cope, J. S. Wyatt, D. T. Delpy, and E. O. R. Reynolds, "Cotside measurement of cerebral blood flow in ill newborn infants by near infrared spectroscopy," Lancet 332, 770-771 (1988).
-
(1988)
Lancet
, vol.332
, pp. 770-771
-
-
Edwards, A.D.1
Richardson, C.2
Cope, M.3
Wyatt, J.S.4
Delpy, D.T.5
Reynolds, E.O.R.6
-
19
-
-
0031777820
-
Regional haemodynamic responses to visual stimulation in awake infants
-
J. Meek, M. Firbank, C. E. Elwell, J. Atkinson, O. Braddick and J. S. Wyatt, "Regional haemodynamic responses to visual stimulation in awake infants.," Pediatr. Res. 42, 840-843 (1998).
-
(1998)
Pediatr. Res.
, vol.42
, pp. 840-843
-
-
Meek, J.1
Firbank, M.2
Elwell, C.E.3
Atkinson, J.4
Braddick, O.5
Wyatt, J.S.6
-
20
-
-
0034678097
-
Spontaneous oscillation of oxy- and deoxyhemoglobin changes with a phase difference throughout the occipital cortex of newborn infants observed using non-invasive optical topography
-
G. Taga, Y. Konishi, A. Maki, T. Tachibana, M. Fujiwara, and H. Koizumi, "Spontaneous oscillation of oxy- and deoxyhemoglobin changes with a phase difference throughout the occipital cortex of newborn infants observed using non-invasive optical topography," Neurosci. Lett. 282, 101-104 (2000).
-
(2000)
Neurosci. Lett.
, vol.282
, pp. 101-104
-
-
Taga, G.1
Konishi, Y.2
Maki, A.3
Tachibana, T.4
Fujiwara, M.5
Koizumi, H.6
-
21
-
-
0032905273
-
Bedside imaging of intracranial hemorrhage in the neonate using light: Comparison with ultrasound, computed tomography, and magnetic resonance imaging
-
S. R. Hintz, W. F. Cheong, J. P. van Houten, D. K. Stevenson, and D. A. Benaron, "Bedside imaging of intracranial hemorrhage in the neonate using light: comparison with ultrasound, computed tomography, and magnetic resonance imaging," Pediatr. Res. 45, 54-59 (1999).
-
(1999)
Pediatr. Res.
, vol.45
, pp. 54-59
-
-
Hintz, S.R.1
Cheong, W.F.2
Van Houten, J.P.3
Stevenson, D.K.4
Benaron, D.A.5
-
22
-
-
0036429981
-
A quantitative comparison of simultaneous BOLD fMRI and NIRS recordings during functional brain activation
-
G. Strangman, J. P. Culver, J. H. Thompson, and D. A. Boas, "A quantitative comparison of simultaneous BOLD fMRI and NIRS recordings during functional brain activation," Neuro-image 17, 719-731 (2002).
-
(2002)
Neuro-image
, vol.17
, pp. 719-731
-
-
Strangman, G.1
Culver, J.P.2
Thompson, J.H.3
Boas, D.A.4
-
23
-
-
0031901460
-
Comparison of finite difference transport and diffusion calculations for photon migration in homogeneous and heterogeneous tissues
-
A. H. Hielscher, R. E. Alcouffe, and R. L. Barhour, "Comparison of finite difference transport and diffusion calculations for photon migration in homogeneous and heterogeneous tissues," Phys. Med. Biol. 43, 1285-1302 (1998).
-
(1998)
Phys. Med. Biol.
, vol.43
, pp. 1285-1302
-
-
Hielscher, A.H.1
Alcouffe, R.E.2
Barhour, R.L.3
-
24
-
-
0032800938
-
Photon migration in non-scattering tissue and the effects on ullage reconstruction
-
H. Dehghani, D. T. Delpy and S. R. Arridge, "Photon migration in non-scattering tissue and the effects on ullage reconstruction," Phys. Med. Biol. 44, 2897-2906 (1999).
-
(1999)
Phys. Med. Biol.
, vol.44
, pp. 2897-2906
-
-
Dehghani, H.1
Delpy, D.T.2
Arridge, S.R.3
-
25
-
-
0002480057
-
Theoretical and experimental investigation of near-infrared light propagation in a model of the adult head
-
E. Okada, M. Firbank, M. Schweiger, S. R. Arridge, M. Cope and D. T. Delpy, "Theoretical and experimental investigation of near-infrared light propagation in a model of the adult head," Appl. Opt. 36, 21-31 (1997).
-
(1997)
Appl. Opt.
, vol.36
, pp. 21-31
-
-
Okada, E.1
Firbank, M.2
Schweiger, M.3
Arridge, S.R.4
Cope, M.5
Delpy, D.T.6
-
26
-
-
0029987994
-
An investigation of light transport through scattering bodies with non-scattering regions
-
M. Firbank, S. R. Arridge, M. Schweiger, and D. T. Delpy, "An investigation of light transport through scattering bodies with non-scattering regions," Phys. Med. Biol. 41, 767-783 (1996).
-
(1996)
Phys. Med. Biol.
, vol.41
, pp. 767-783
-
-
Firbank, M.1
Arridge, S.R.2
Schweiger, M.3
Delpy, D.T.4
-
27
-
-
0035760913
-
Radiosity diffusion model in 3D
-
Photon Migration, Optical Coherence Tomography, and Microscopy, S. Andersson-Engels and M. F. Kaschke, eds.
-
J. D. Riley, S. R. Arridge, Y. Chrysanthou, H. Dehghani, E. M. Hillman, and M. Schweiger, "Radiosity diffusion model in 3D," in Photon Migration, Optical Coherence Tomography, and Microscopy, S. Andersson-Engels and M. F. Kaschke, eds., Proc. SPIE 4431, 153-164 (2001).
-
(2001)
Proc. SPIE
, vol.4431
, pp. 153-164
-
-
Riley, J.D.1
Arridge, S.R.2
Chrysanthou, Y.3
Dehghani, H.4
Hillman, E.M.5
Schweiger, M.6
-
28
-
-
0030370419
-
Non-diffusive photon migration in homogeneous and heterogeneous tissues
-
Photon Propagation in Tissue II, B. Chance, D. Benaron, G. J. Müller, eds.
-
A. H. Hielscher and R. E. Alcouffe, "Non-diffusive photon migration in homogeneous and heterogeneous tissues," in Photon Propagation in Tissue II, B. Chance, D. Benaron, G. J. Müller, eds., Proc. SPIE 2925, 22-30 (1996).
-
(1996)
Proc. SPIE
, vol.2925
, pp. 22-30
-
-
Hielscher, A.H.1
Alcouffe, R.E.2
-
29
-
-
84894006311
-
Image reconstruction in the presence of a void region
-
Optical Society of America, Washington, D.C.
-
H. Dehghani, S. R. Arridge, M. Schweiger, and D. T. Delpy, "Image reconstruction in the presence of a void region," in Digest of OSA Biomedical Topical Meetings (Optical Society of America, Washington, D.C. 2000), pp. 351-353.
-
(2000)
Digest of OSA Biomedical Topical Meetings
, pp. 351-353
-
-
Dehghani, H.1
Arridge, S.R.2
Schweiger, M.3
Delpy, D.T.4
-
30
-
-
0002651628
-
Normalized-constraint algorithm for minimizing inter-parameter crosstalk in DC optical tomography
-
Y. Pei, H. L. Graber, and R. L. Barbour, "Normalized-constraint algorithm for minimizing inter-parameter crosstalk in DC optical tomography," Opt. Express 11, 97-109 (2001).
-
(2001)
Opt. Express
, vol.11
, pp. 97-109
-
-
Pei, Y.1
Graber, H.L.2
Barbour, R.L.3
-
31
-
-
0036473510
-
Instrumentation for fast functional optical tomography
-
C. H. Schmitz, M. Locker, J. M. Lasker, A. H. Hielscher, and R. L. Barbour, "Instrumentation for fast functional optical tomography," Rev. Sci. Instrum. 73, 429-439 (2002).
-
(2002)
Rev. Sci. Instrum.
, vol.73
, pp. 429-439
-
-
Schmitz, C.H.1
Locker, M.2
Lasker, J.M.3
Hielscher, A.H.4
Barbour, R.L.5
-
32
-
-
0033731736
-
A method for 3D time-resolved optical tomography
-
S. R. Arridge, J. C. Hebden, M. Schweiger, F. E. W. Schmidt, M. E. Fry, E. M. C. Hillman, H. Dehghani, and D. T. Delpy, "A method for 3D time-resolved optical tomography," Int. J. Imaging Syst. Technol. 11, 2-11 (2000).
-
(2000)
Int. J. Imaging Syst. Technol.
, vol.11
, pp. 2-11
-
-
Arridge, S.R.1
Hebden, J.C.2
Schweiger, M.3
Schmidt, F.E.W.4
Fry, M.E.5
Hillman, E.M.C.6
Dehghani, H.7
Delpy, D.T.8
-
33
-
-
0029001020
-
An improved design for a stable and reproducible phantom material for use in near-infrared spectroscopy and imaging
-
M. Firbank, M. Oda, and D. T. Delpy, "An improved design for a stable and reproducible phantom material for use in near-infrared spectroscopy and imaging," Phys. Med. Biol. 40, 955-961 (1995).
-
(1995)
Phys. Med. Biol.
, vol.40
, pp. 955-961
-
-
Firbank, M.1
Oda, M.2
Delpy, D.T.3
-
34
-
-
0012367176
-
Optical tomography of a realistic neonatal head phantom
-
A. P. Gibson, R. M. Yusof, H. Dehghani, J. Riley, N. Everdell, R. Richards, J. C. Hebden, M. Schweiger, S. R. Arridge, and D. T. Delpy, "Optical tomography of a realistic neonatal head phantom," Appl. Opt. 42, 3109-3116 (2003).
-
(2003)
Appl. Opt.
, vol.42
, pp. 3109-3116
-
-
Gibson, A.P.1
Yusof, R.M.2
Dehghani, H.3
Riley, J.4
Everdell, N.5
Richards, R.6
Hebden, J.C.7
Schweiger, M.8
Arridge, S.R.9
Delpy, D.T.10
-
35
-
-
0000350762
-
Multiple-slice imaging of a tissue-equivalent phantom by use of time-resolved optical tomography
-
F. E. W. Schmidt, J. C. Hebden, E. M. C. Hillman, M. E. Fry, M. Schweiger, H. Dehghani, D. T. Delpy, and S. R. Arridge, "Multiple-slice imaging of a tissue-equivalent phantom by use of time-resolved optical tomography," Appl. Opt. 39, 3380-3387 (2000).
-
(2000)
Appl. Opt.
, vol.39
, pp. 3380-3387
-
-
Schmidt, F.E.W.1
Hebden, J.C.2
Hillman, E.M.C.3
Fry, M.E.4
Schweiger, M.5
Dehghani, H.6
Delpy, D.T.7
Arridge, S.R.8
-
36
-
-
0037208324
-
Assessment of an in situ temporal calibration method for time-resolved optical tomography
-
J. C. Hebden, F. M. Gonzalez, A. P. Gibson, E. M. Hillman, R. M. Yusof, N. Everdell, D. T. Delpy, G. Zaccanti, and F. Martelli, "Assessment of an in situ temporal calibration method for time-resolved optical tomography," J. Biomed. Opt. 8, 87-92 (2003).
-
(2003)
J. Biomed. Opt.
, vol.8
, pp. 87-92
-
-
Hebden, J.C.1
Gonzalez, F.M.2
Gibson, A.P.3
Hillman, E.M.4
Yusof, R.M.5
Everdell, N.6
Delpy, D.T.7
Zaccanti, G.8
Martelli, F.9
-
37
-
-
84880765336
-
NETGEN - An advancing front 2D/3D-mesh gen erator based on abstract rules
-
J. Schöberl, "NETGEN - An advancing front 2D/3D-mesh gen erator based on abstract rules," Comput. Visual. Sci. 1, 41-52 (1997).
-
(1997)
Comput. Visual. Sci.
, vol.1
, pp. 41-52
-
-
Schöberl, J.1
-
38
-
-
0242500986
-
A method for generating patient-specific finite element meshes for head modelling
-
A. P. Gibson, J. Riley, M. Schweiger, J. C. Hebden, S. R. Arridge, and D. T. Delpy, "A method for generating patient-specific finite element meshes for head modelling," Phys. Med. Biol. 48, 481-495 (2003).
-
(2003)
Phys. Med. Biol.
, vol.48
, pp. 481-495
-
-
Gibson, A.P.1
Riley, J.2
Schweiger, M.3
Hebden, J.C.4
Arridge, S.R.5
Delpy, D.T.6
-
39
-
-
0036617002
-
Linear single-step image reconstruction in the presence of nonscattering regions
-
H. Dehghani and D. T. Delpy, "Linear single-step image reconstruction in the presence of nonscattering regions," J. Opt Soc. Am. A 19, 1162-1171 (2002).
-
(2002)
J. Opt Soc. Am. A
, vol.19
, pp. 1162-1171
-
-
Dehghani, H.1
Delpy, D.T.2
-
40
-
-
0028826415
-
The finite element method for the propagation of light in scattering media: Boundary and source conditions
-
M. Schweiger, S. R. Arridge, M. Hiraoka, and D. T. Delpy, "The finite element method for the propagation of light in scattering media: boundary and source conditions," Med. Phys. 22, 1779-1792 (1995).
-
(1995)
Med. Phys.
, vol.22
, pp. 1779-1792
-
-
Schweiger, M.1
Arridge, S.R.2
Hiraoka, M.3
Delpy, D.T.4
-
41
-
-
0000475817
-
Optical tomography in the presence of void regions
-
H. Dehghani, S. R. Arridge, M. Schweiger, and D. T. Delpy, "Optical tomography in the presence of void regions," J. Opt Soc. Am. A 17, 1659-1670 (2000).
-
(2000)
J. Opt Soc. Am. A
, vol.17
, pp. 1659-1670
-
-
Dehghani, H.1
Arridge, S.R.2
Schweiger, M.3
Delpy, D.T.4
-
42
-
-
0037872005
-
Near-infrared light propagation in an adult head model. I. Modeling of low-level scattering in the cerebrospinal fluid layer
-
E. Okada and D. T. Delpy, "Near-infrared light propagation in an adult head model. I. Modeling of low-level scattering in the cerebrospinal fluid layer," Appl. Opt. 42, 2906-2914 (2003).
-
(2003)
Appl. Opt.
, vol.42
, pp. 2906-2914
-
-
Okada, E.1
Delpy, D.T.2
-
43
-
-
0000945932
-
Three dimensional Monte Carlo code for photon migration through complex heterogeneous media including the adult human head
-
D. A. Boas, J. P. Culver, J. J. Stott, and A. K. Dunn, "Three dimensional Monte Carlo code for photon migration through complex heterogeneous media including the adult human head," Opt. Express 10, 159-169 (2002).
-
(2002)
Opt. Express
, vol.10
, pp. 159-169
-
-
Boas, D.A.1
Culver, J.P.2
Stott, J.J.3
Dunn, A.K.4
-
44
-
-
0038548335
-
Hybrid Monte Carlo-diffusion method for light propagation in tissue with a low-scattering region
-
T. Hayashi, Y. Kashio, and E. Okada, "Hybrid Monte Carlo-diffusion method for light propagation in tissue with a low-scattering region," Appl. Opt. 42, 2888-2896 (2003).
-
(2003)
Appl. Opt.
, vol.42
, pp. 2888-2896
-
-
Hayashi, T.1
Kashio, Y.2
Okada, E.3
-
45
-
-
0000405886
-
A transport-backtransport method for optical tomography
-
O. Dorn, "A transport-backtransport method for optical tomography," Inverse Probl. 14, 1107-1130 (1998).
-
(1998)
Inverse Probl.
, vol.14
, pp. 1107-1130
-
-
Dorn, O.1
-
46
-
-
0032779242
-
Iterative reconstruction scheme for optical tomography based on the equation of radiative transfer
-
A. D. Klose and A. H. Hielscher, "Iterative reconstruction scheme for optical tomography based on the equation of radiative transfer," Med. Phys. 28, 1698-1707 (1999).
-
(1999)
Med. Phys.
, vol.28
, pp. 1698-1707
-
-
Klose, A.D.1
Hielscher, A.H.2
-
47
-
-
0000042964
-
3D optical tomography in the presence of void regions
-
J. Riley, H. Dehghani, M. Schweiger, S. R. Arridge, J. Ripoll, and M. Nieto-Vesperinas, "3D optical tomography in the presence of void regions," Opt. Express 7, 462-467 (2000).
-
(2000)
Opt. Express
, vol.7
, pp. 462-467
-
-
Riley, J.1
Dehghani, H.2
Schweiger, M.3
Arridge, S.R.4
Ripoll, J.5
Nieto-Vesperinas, M.6
-
48
-
-
0038455762
-
Effect of roughness in nondiffusive regions within biological media
-
J. Ripoll, M. Nieto-Vesperinas, and S. R. Arridge, "Effect of roughness in nondiffusive regions within biological media," J. Opt Soc. Am. A 18, 940-947 (2001).
-
(2001)
J. Opt Soc. Am. A
, vol.18
, pp. 940-947
-
-
Ripoll, J.1
Nieto-Vesperinas, M.2
Arridge, S.R.3
-
49
-
-
0141572400
-
Cerebrospinal fluid analysis
-
D. A. Seehusen, M. M. Reeves, and D. A. Fomin, "Cerebrospinal fluid analysis," Am. Fam. Physician 68, 1103-1108 (2003).
-
(2003)
Am. Fam. Physician
, vol.68
, pp. 1103-1108
-
-
Seehusen, D.A.1
Reeves, M.M.2
Fomin, D.A.3
|