-
1
-
-
0030162614
-
Probability of malignancy in solitary pulmonary nodules using fluorine-18-FDG and PET
-
N. Gupta, J. Maloof, and E. Gunel Probability of malignancy in solitary pulmonary nodules using fluorine-18-FDG and PET J Nucl Med 37 6 1996 943 948
-
(1996)
J Nucl Med
, vol.37
, Issue.6
, pp. 943-948
-
-
Gupta, N.1
Maloof, J.2
Gunel, E.3
-
2
-
-
0027526918
-
Determining the likelihood of malignancy in solitary pulmonary nodules with Bayesian analysis. Part I. Theory
-
J. Gurney Determining the likelihood of malignancy in solitary pulmonary nodules with Bayesian analysis. Part I. Theory Radiology 186 2 1993 405 413
-
(1993)
Radiology
, vol.186
, Issue.2
, pp. 405-413
-
-
Gurney, J.1
-
3
-
-
0023264935
-
The solitary pulmonary nodule. Assessment, diagnosis, and management
-
N. Khouri, M. Meziane, E. Zerhouni, E. Fishman, and S. Siegelman The solitary pulmonary nodule. Assessment, diagnosis, and management Chest 91 1 1987 128 133
-
(1987)
Chest
, vol.91
, Issue.1
, pp. 128-133
-
-
Khouri, N.1
Meziane, M.2
Zerhouni, E.3
Fishman, E.4
Siegelman, S.5
-
4
-
-
0031403024
-
The probability of malignancy in solitary pulmonary nodules Application to small radiologically indeterminate nodules
-
S. Swensen, M. Silverstein, D. Ilstrup, C. Schleck, and E. Edell The probability of malignancy in solitary pulmonary nodules Application to small radiologically indeterminate nodules Arch Intern Med 157 8 1997 849 855
-
(1997)
Arch Intern Med
, vol.157
, Issue.8
, pp. 849-855
-
-
Swensen, S.1
Silverstein, M.2
Ilstrup, D.3
Schleck, C.4
Edell, E.5
-
5
-
-
0035925107
-
Accuracy of positron emission tomography for diagnosis of pulmonary nodules and mass lesions: A meta-analysis
-
M. Gould, C. Maclean, W. Kuschner, C. Rydzak, and D. Owens Accuracy of positron emission tomography for diagnosis of pulmonary nodules and mass lesions: a meta-analysis JAMA 285 7 2001 914 924
-
(2001)
JAMA
, vol.285
, Issue.7
, pp. 914-924
-
-
Gould, M.1
MacLean, C.2
Kuschner, W.3
Rydzak, C.4
Owens, D.5
-
6
-
-
0038412655
-
Cost-effectiveness of alternative management strategies for patients with solitary pulmonary nodules
-
M. Gould, G. Sanders, and P. Barnett Cost-effectiveness of alternative management strategies for patients with solitary pulmonary nodules Ann Intern Med 138 9 2003 724 735
-
(2003)
Ann Intern Med
, vol.138
, Issue.9
, pp. 724-735
-
-
Gould, M.1
Sanders, G.2
Barnett, P.3
-
7
-
-
0037865723
-
Clinical practice. the solitary pulmonary nodule
-
D. Ost, A. Fein, and S. Feinsilver Clinical practice. The solitary pulmonary nodule N Engl J Med 348 25 2003 2535 2542
-
(2003)
N Engl J Med
, vol.348
, Issue.25
, pp. 2535-2542
-
-
Ost, D.1
Fein, A.2
Feinsilver, S.3
-
9
-
-
0032722258
-
The clinical usefulness of F-18 FDG coincidence PET without attenuation correction and without whole-body scanning mode in pulmonary lesions comparison with CT, MRI, and clinical findings
-
S. Kim, C. Park, M. Han, S. Hwang, C. Lee, and M. Pai The clinical usefulness of F-18 FDG coincidence PET without attenuation correction and without whole-body scanning mode in pulmonary lesions comparison with CT, MRI, and clinical findings Clin Nucl Med 24 12 1999 945 949
-
(1999)
Clin Nucl Med
, vol.24
, Issue.12
, pp. 945-949
-
-
Kim, S.1
Park, C.2
Han, M.3
Hwang, S.4
Lee, C.5
Pai, M.6
-
10
-
-
0032930912
-
Assessment of pulmonary lesions with 18F-fluorodeoxyglucose positron imaging using coincidence mode gamma cameras
-
W. Weber, C. Young, and H. Abdel-Dayem Assessment of pulmonary lesions with 18F-fluorodeoxyglucose positron imaging using coincidence mode gamma cameras J Nucl Med 40 4 1999 574 578
-
(1999)
J Nucl Med
, vol.40
, Issue.4
, pp. 574-578
-
-
Weber, W.1
Young, C.2
Abdel-Dayem, H.3
-
11
-
-
0034744105
-
The clinical value of 18F-FDG detection with a dual-head coincidence camera: A review
-
I. Ak, J. Blokland, E. Pauwels, and M. Stokkel The clinical value of 18F-FDG detection with a dual-head coincidence camera: a review Eur J Nucl Med 28 6 2001 763 778
-
(2001)
Eur J Nucl Med
, vol.28
, Issue.6
, pp. 763-778
-
-
Ak, I.1
Blokland, J.2
Pauwels, E.3
Stokkel, M.4
-
12
-
-
17944363487
-
Design and performance of collimated coincidence point sources for simultaneous transmission measurements in 3D PET
-
C. Watson, L. Eriksson, M. Casey, W. Jones, J. Moyers, and A. van Lingen Design and performance of collimated coincidence point sources for simultaneous transmission measurements in 3D PET IEEE Nucl Sci 48 2001 673 679
-
(2001)
IEEE Nucl Sci
, vol.48
, pp. 673-679
-
-
Watson, C.1
Eriksson, L.2
Casey, M.3
Jones, W.4
Moyers, J.5
Van Lingen, A.6
-
13
-
-
0003155529
-
Performance of a LSO/NaI(T1) phoswich detector for a combined PET/SPECT imaging system
-
M. Schmand, M. Dahlbom, and L. Eriksson Performance of a LSO/NaI(T1) phoswich detector for a combined PET/SPECT imaging system J Nucl Med 39 1998 9
-
(1998)
J Nucl Med
, vol.39
, pp. 9
-
-
Schmand, M.1
Dahlbom, M.2
Eriksson, L.3
-
14
-
-
0001307056
-
Initial characterization of a new hybrid tomograph: LSO/NaI PET/SPECT
-
A. van Lingen, B. Bendriem, P. Luk, W. Jones, J. Young, and R. Nutt Initial characterization of a new hybrid tomograph: LSO/NaI PET/SPECT J Nucl Med 41 2001 20P
-
(2001)
J Nucl Med
, vol.41
-
-
Van Lingen, A.1
Bendriem, B.2
Luk, P.3
Jones, W.4
Young, J.5
Nutt, R.6
-
15
-
-
0141542629
-
Melanoma patients evaluated by four different positron emission tomography reconstruction techniques
-
D. Schauwecker, A. Siddiqui, and J. Wagner Melanoma patients evaluated by four different positron emission tomography reconstruction techniques Nucl Med Commun 24 3 2003 281 289
-
(2003)
Nucl Med Commun
, vol.24
, Issue.3
, pp. 281-289
-
-
Schauwecker, D.1
Siddiqui, A.2
Wagner, J.3
-
16
-
-
4544239149
-
The performance of (18)F-fluorodeoxyglucose positron emission tomography in small solitary pulmonary nodules
-
G. Herder, R. Golding, and O.S. Hoekstra The performance of (18)F-fluorodeoxyglucose positron emission tomography in small solitary pulmonary nodules Eur J Nucl Med Mol Imaging 31 2004 1231 1236
-
(2004)
Eur J Nucl Med Mol Imaging
, vol.31
, pp. 1231-1236
-
-
Herder, G.1
Golding, R.2
Hoekstra, O.S.3
-
17
-
-
0034667846
-
Breast imaging with positron emission tomography and fluorine-18 fluorodeoxyglucose: Use and limitations
-
N. Avril, C. Rose, and M. Schelling Breast imaging with positron emission tomography and fluorine-18 fluorodeoxyglucose: use and limitations J Clin Oncol 18 20 2000 3495 3502
-
(2000)
J Clin Oncol
, vol.18
, Issue.20
, pp. 3495-3502
-
-
Avril, N.1
Rose, C.2
Schelling, M.3
-
18
-
-
0032945147
-
Imaging of lung cancer with fluorine-18 fluorodeoxyglucose: Comparison of a dual-head gamma camera in coincidence mode with a full-ring positron emission tomography system
-
W. Weber, J. Neverve, and J. Sklarek Imaging of lung cancer with fluorine-18 fluorodeoxyglucose: comparison of a dual-head gamma camera in coincidence mode with a full-ring positron emission tomography system Eur J Nucl Med 26 4 1999 388 395
-
(1999)
Eur J Nucl Med
, vol.26
, Issue.4
, pp. 388-395
-
-
Weber, W.1
Neverve, J.2
Sklarek, J.3
-
19
-
-
0041464868
-
Early lung-cancer detection with spiral CT and positron emission tomography in heavy smokers: 2-year results
-
U. Pastorino, M. Bellomi, and C. Landoni Early lung-cancer detection with spiral CT and positron emission tomography in heavy smokers: 2-year results Lancet 362 9384 2003 593 597
-
(2003)
Lancet
, vol.362
, Issue.9384
, pp. 593-597
-
-
Pastorino, U.1
Bellomi, M.2
Landoni, C.3
-
20
-
-
0031046791
-
Pulmonary nodules: Differential diagnosis using 18F-fluorodeoxyglucose single-photon emission computed tomography
-
D. Worsley, A. Celler, and M. Adam Pulmonary nodules: differential diagnosis using 18F-fluorodeoxyglucose single-photon emission computed tomography Am J Roentgenol 168 3 1997 771 774
-
(1997)
Am J Roentgenol
, vol.168
, Issue.3
, pp. 771-774
-
-
Worsley, D.1
Celler, A.2
Adam, M.3
-
21
-
-
0032907496
-
FDG SPECT in patients with lung masses
-
S. Martin, W. Drane, E. Harman, J. Fenton, and L. Quesenberry FDG SPECT in patients with lung masses Chest 115 4 1999 1012 1017
-
(1999)
Chest
, vol.115
, Issue.4
, pp. 1012-1017
-
-
Martin, S.1
Drane, W.2
Harman, E.3
Fenton, J.4
Quesenberry, L.5
-
22
-
-
0037253902
-
Prospective use of serial questionnaires to evaluate the therapeutic efficacy of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in suspected lung cancer
-
G. Herder, H. van Tinteren, and E. Comans Prospective use of serial questionnaires to evaluate the therapeutic efficacy of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in suspected lung cancer Thorax 58 1 2003 47 51
-
(2003)
Thorax
, vol.58
, Issue.1
, pp. 47-51
-
-
Herder, G.1
Van Tinteren, H.2
Comans, E.3
-
23
-
-
2942547509
-
Evaluation of FDG PET scanning for pulmonary nodules less than 3 cm, with special reference to the CT images
-
H. Nomori, K. Watanabe, and K. Ohtsuka Evaluation of FDG PET scanning for pulmonary nodules less than 3 cm, with special reference to the CT images Lung Cancer 45 1 2004 19 27
-
(2004)
Lung Cancer
, vol.45
, Issue.1
, pp. 19-27
-
-
Nomori, H.1
Watanabe, K.2
Ohtsuka, K.3
-
24
-
-
0034092414
-
Scintillation crystals for PET
-
C.L. Melcher Scintillation crystals for PET J Nucl Med 41 6 2000 1051 1055
-
(2000)
J Nucl Med
, vol.41
, Issue.6
, pp. 1051-1055
-
-
Melcher, C.L.1
-
25
-
-
1842764967
-
Initial experience with a prototype dual-crystal (LSO/NaI) dual-head coincidence camera in oncology
-
U. Joshi, O.S. Hoekstra, and R. Boellaard Initial experience with a prototype dual-crystal (LSO/NaI) dual-head coincidence camera in oncology Eur J Nucl Med Mol Imaging 31 4 2004 596 598
-
(2004)
Eur J Nucl Med Mol Imaging
, vol.31
, Issue.4
, pp. 596-598
-
-
Joshi, U.1
Hoekstra, O.S.2
Boellaard, R.3
-
26
-
-
0035019192
-
Advantage of delayed whole-body FDG-PET imaging for tumour detection
-
K. Kubota, M. Itoh, and K. Ozaki Advantage of delayed whole-body FDG-PET imaging for tumour detection Eur J Nucl Med 28 6 2001 696 703
-
(2001)
Eur J Nucl Med
, vol.28
, Issue.6
, pp. 696-703
-
-
Kubota, K.1
Itoh, M.2
Ozaki, K.3
|